RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis

      한글로보기

      https://www.riss.kr/link?id=A105966424

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: It has been suggested that resonance frequency analysis (RFA) can measure changes in the stability of dental implants during osseointegration. This retrospective study aimed to evaluate dental implant stability at the time of surgery (primary...

      Purpose: It has been suggested that resonance frequency analysis (RFA) can measure changes in the stability of dental implants during osseointegration. This retrospective study aimed to evaluate dental implant stability at the time of surgery (primary stability; PS) and secondary stability (SS) after ossseointegration using RFA, and to investigate the relationship between implant stability and cortical bone thickness.
      Methods: In total, 113 patients who attended the Tohoku University Hospital Dental Implant Center were included in this study. A total of 229 implants were placed in either the mandibular region (n=118) or the maxilla region (n=111), with bone augmentation procedures used in some cases. RFA was performed in 3 directions, and the lowest value was recorded. The preoperative thickness of cortical bone at the site of implant insertion was measured digitally using computed tomography, excluding cases of bone grafts and immediate implant placements.
      Results: The mean implant stability quotient (ISQ) was 69.34±9.43 for PS and 75.99±6.23 for SS. The mandibular group had significantly higher mean ISQ values than the maxillary group for both PS and SS (P<0.01). A significant difference was found in the mean ISQ values for PS between 1-stage and 2-stage surgery (P<0.5). The mean ISQ values in the non-augmentation group were higher than in the augmentation group for both PS and SS (P<0.01). A weak positive correlation was observed between cortical bone thickness and implant stability for both PS and SS in all cases (P<0.01).
      Conclusions: Based on the present study, the ISQ may be affected by implant position site, the use of a bone graft, and cortical bone thickness before implant therapy

      더보기

      참고문헌 (Reference)

      1 Turkyilmaz I, "Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data" 10 : 231-237, 2008

      2 Geckili O, "Three-year radiologic follow-up of marginal bone loss around titanium dioxide grit-blasted dental implants with and without fluoride treatment" 26 : 319-324, 2011

      3 Albrektsson T, "The long-term efficacy of currently used dental implants: a review and proposed criteria of success" 1 : 11-25, 1986

      4 Lekholm U, "Survival of the Brånemark implant in partially edentulous jaws: a 10-year prospective multicenter study" 14 : 639-645, 1999

      5 Al-Khaldi N, "Stability of dental implants in grafted bone in the anterior maxilla: longitudinal study" 49 : 319-323, 2011

      6 Balleri P, "Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study" 4 : 128-132, 2002

      7 Friberg B, "Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study" 28 : 266-272, 1999

      8 Rasmusson L, "Stability evaluation of implants integrated in grafted and nongrafted maxillary bone: a clinical study from implant placement to abutment connection" 14 : 61-66, 2012

      9 Turkyilmaz I, "Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols" 17 : 501-505, 2006

      10 Ersanli S, "Resonance frequency analysis of one-stage dental implant stability during the osseointegration period" 76 : 1066-1071, 2005

      1 Turkyilmaz I, "Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data" 10 : 231-237, 2008

      2 Geckili O, "Three-year radiologic follow-up of marginal bone loss around titanium dioxide grit-blasted dental implants with and without fluoride treatment" 26 : 319-324, 2011

      3 Albrektsson T, "The long-term efficacy of currently used dental implants: a review and proposed criteria of success" 1 : 11-25, 1986

      4 Lekholm U, "Survival of the Brånemark implant in partially edentulous jaws: a 10-year prospective multicenter study" 14 : 639-645, 1999

      5 Al-Khaldi N, "Stability of dental implants in grafted bone in the anterior maxilla: longitudinal study" 49 : 319-323, 2011

      6 Balleri P, "Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study" 4 : 128-132, 2002

      7 Friberg B, "Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study" 28 : 266-272, 1999

      8 Rasmusson L, "Stability evaluation of implants integrated in grafted and nongrafted maxillary bone: a clinical study from implant placement to abutment connection" 14 : 61-66, 2012

      9 Turkyilmaz I, "Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols" 17 : 501-505, 2006

      10 Ersanli S, "Resonance frequency analysis of one-stage dental implant stability during the osseointegration period" 76 : 1066-1071, 2005

      11 Ostman PO, "Resonance frequency analysis measurements of implants at placement surgery" 19 : 77-83, 2006

      12 Degidi M, "Primary stability determination of implants inserted in sinus augmented sites: 1-step versus 2-step procedure" 22 : 530-533, 2013

      13 Nedir R, "Predicting osseointegration by means of implant primary stability" 15 : 520-528, 2004

      14 Karl M, "Parameters of resonance frequency measurement values: a retrospective study of 385 ITI dental implants" 19 : 214-218, 2008

      15 Albrektsson T, "Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man" 52 : 155-170, 1981

      16 Sjöström M, "Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6 months of loading" 34 : 45-51, 2005

      17 Becker W, "Long-term evaluation of 282 implants in maxillary and mandibular molar positions: a prospective study" 70 : 896-901, 1999

      18 Benic GI, "Loading protocols for single-implant crowns: a systematic review and meta-analysis" 29 (29): 222-238, 2014

      19 Schimmel M, "Loading protocols for implant-supported overdentures in the edentulous jaw: a systematic review and meta-analysis" 29 (29): 271-286, 2014

      20 Ivanoff CJ, "Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits" 7 : 120-127, 1996

      21 Ivanoff CJ, "Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits" 7 : 120-127, 1996

      22 Miyamoto I, "Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospective, biomechanical, and imaging study" 37 : 776-780, 2005

      23 Bischof M, "Implant stability measurement of delayed and immediately loaded implants during healing" 15 : 529-539, 2004

      24 Schrott A, "Implant loading protocols for partially edentulous patients with extended edentulous sites--a systematic review and meta-analysis" 29 (29): 239-255, 2014

      25 Manzano-Moreno FJ, "Factors affecting dental implant stability measured using the ostell mentor device: a systematic review" 24 : 565-577, 2015

      26 Marković A, "Evaluation of primary stability of self-tapping and non-self-tapping dental implants. A 12-week clinical study" 15 : 341-349, 2013

      27 Seong WJ, "Comparison of push-in versus pull-out tests on bone-implant interfaces of rabbit tibia dental implant healing model" 15 : 460-469, 2013

      28 Oh JS, "Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment" 113 : e35-e40, 2012

      29 Atieh MA, "Can resonance frequency analysis predict failure risk of immediately loaded implants" 25 : 326-339, 2012

      30 Cochran DL, "Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible" 40 : 1-11, 1998

      31 Shahlaie M, "Bone density assessments of dental implant sites: 1. Quantitative computed tomography" 18 : 224-231, 2003

      32 Norton MR, "Bone classification: an objective scale of bone density using the computerized tomography scan" 12 : 79-84, 2001

      33 Meredith N, "Assessment of implant stability as a prognostic determinant" 11 : 491-501, 1998

      34 Tallarico M, "A prospective case-control clinical trial comparing 1- and 2-stage Nobel Biocare TiUnite implants: resonance frequency analysis assessed by Osstell Mentor during integration" 42 : 635-644, 2011

      35 Sennerby L, "A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone" 7 : 62-71, 1992

      36 Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw" 10 : 387-416, 1981

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2012-03-21 학술지명변경 한글명 : The Journal of the Korean Academy of Periodontology (JPIS) -> Journal of Periodontal & Implant Science
      외국어명 : THE JOURNAL OF KOREAN ACADEMY OF PERIODONTOLOGY -> Journal of Periodontal & Implant Science
      KCI등재
      2011-03-22 학술지명변경 한글명 : 대한치주과학회지 -> The Journal of the Korean Academy of Periodontology (JPIS) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2004-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2002-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.91 0.14 0.66
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.56 0.45 0.49 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼