RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재

      액체 수송계에 대한 고장 검출 진단시스템의 설계 = Design of a Fault Detection and Isolation System for a Liquid Transprotation System

      한글로보기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      In this study, a fault detection and isolation system(FDIS) is constructed for the supervision of the liquid transportation system that is composed of DC-motor, centrifugal pump and pipe-lines. The FDIS consists of the residual generator, detection logic and fault isolation logic and it can be classified as the dedicated observer scheme(DOS). The system can detect the occurrence of sensor faults and identify the failed, sensor. And the process faults that may occurr in the components such as DC-motor, centrifugal pump and pipe-lines can be promptly detected and diagnosed with the FDIS. It may provide an effective way that will enhance the safety and the functional reliability of the fluid transportation systems.
      번역하기

      In this study, a fault detection and isolation system(FDIS) is constructed for the supervision of the liquid transportation system that is composed of DC-motor, centrifugal pump and pipe-lines. The FDIS consists of the residual generator, detection lo...

      In this study, a fault detection and isolation system(FDIS) is constructed for the supervision of the liquid transportation system that is composed of DC-motor, centrifugal pump and pipe-lines. The FDIS consists of the residual generator, detection logic and fault isolation logic and it can be classified as the dedicated observer scheme(DOS). The system can detect the occurrence of sensor faults and identify the failed, sensor. And the process faults that may occurr in the components such as DC-motor, centrifugal pump and pipe-lines can be promptly detected and diagnosed with the FDIS. It may provide an effective way that will enhance the safety and the functional reliability of the fluid transportation systems.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼