    CT Venography for Deep Vein Thrombosis Using a Low Tube Voltage (100 kVp) Setting Could Increase Venous Enhancement and Reduce the Amount of Administered Iodine

    한글로보기

    https://www.riss.kr/link?id=A104530301

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
      • URL 복사
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Objective: To investigate the validity of the 100 kVp setting in CT venography (CTV) in the diagnosis of deep vein thrombosis (DVT), and to evaluate the feasibility of reducing the amount of administered iodine in this setting.
    Materials and Methods: After receiving the contrast medium (CM) of 2.0 mL/kg, 88 patients underwent CTV of the pelvis and lower extremities by using one of four protocols: Group A, 120 kVp setting and 370 mgI/mL CM; group B, 120 kVp and 300 mgI/mL; group C, 100 kVp and 370 mgI/mL; group D, 100 kVp and 300 mgI/mL. The groups were evaluated for venous attenuation, vein-to-muscle contrast-to-noise ratio (CNRVEIN), DVT-to-vein contrast-to-noise ratio (CNRDVT), and subjective degree of venous enhancement and image quality.
    Results: Venous attenuation and CNRVEIN were significantly higher in group C (144.3 Hounsfield unit [HU] and 11.9), but there was no significant difference between group A (118.0 HU and 8.2) and D (122.4 HU and 7.9). The attenuation value of DVT was not significantly different among the four groups, and group C had a higher absolute CNRDVT than the other groups. The overall diagnostic image quality and venous enhancement were significantly higher in group C, but there was no difference between groups A and D.
    Conclusion: The 100 kVp setting in CTV substantially help improve venous enhancement and CNRVEIN. Furthermore, it enables to reduce the amount of administered iodine while maintaining venous attenuation, as compared with the 120 kVp setting.
    번역하기

    Objective: To investigate the validity of the 100 kVp setting in CT venography (CTV) in the diagnosis of deep vein thrombosis (DVT), and to evaluate the feasibility of reducing the amount of administered iodine in this setting. Materials and Methods:...

    Objective: To investigate the validity of the 100 kVp setting in CT venography (CTV) in the diagnosis of deep vein thrombosis (DVT), and to evaluate the feasibility of reducing the amount of administered iodine in this setting.
    Materials and Methods: After receiving the contrast medium (CM) of 2.0 mL/kg, 88 patients underwent CTV of the pelvis and lower extremities by using one of four protocols: Group A, 120 kVp setting and 370 mgI/mL CM; group B, 120 kVp and 300 mgI/mL; group C, 100 kVp and 370 mgI/mL; group D, 100 kVp and 300 mgI/mL. The groups were evaluated for venous attenuation, vein-to-muscle contrast-to-noise ratio (CNRVEIN), DVT-to-vein contrast-to-noise ratio (CNRDVT), and subjective degree of venous enhancement and image quality.
    Results: Venous attenuation and CNRVEIN were significantly higher in group C (144.3 Hounsfield unit [HU] and 11.9), but there was no significant difference between group A (118.0 HU and 8.2) and D (122.4 HU and 7.9). The attenuation value of DVT was not significantly different among the four groups, and group C had a higher absolute CNRDVT than the other groups. The overall diagnostic image quality and venous enhancement were significantly higher in group C, but there was no difference between groups A and D.
    Conclusion: The 100 kVp setting in CTV substantially help improve venous enhancement and CNRVEIN. Furthermore, it enables to reduce the amount of administered iodine while maintaining venous attenuation, as compared with the 120 kVp setting.

    더보기

    참고문헌 (Reference)

    1 Kalva SP, "Venous thromboembolism: indirect CT venography during CT pulmonary angiography--should the pelvis be imaged?" 246 : 605-611, 2008

    2 Reichert M, "Venous thromboembolism: additional diagnostic value and radiation dose of pelvic CT venography in patients with suspected pulmonary embolism" 80 : 50-53, 2011

    3 Fujikawa A, "Vascular enhancement and image quality of CT venography: comparison of standard and low kilovoltage settings" 197 : 838-843, 2011

    4 Lee W, "ThreeDimensional CT venography of varicose veins of the lower extremity" 191 : 1186-1191, 2008

    5 Schindera ST, "Thoracoabdominal-aortoiliac multidetectorrow CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose" 44 : 650-655, 2009

    6 Landis JR, "The measurement of observer agreement for categorical data" 33 : 159-174, 1977

    7 Ulas Savas Yavas, "The Interobserver Agreement between Residents and Experienced Radiologists for Detecting Pulmonary Embolism and DVT with Using CT Pulmonary Angiography and Indirect CT Venography" 대한영상의학회 9 (9): 498-502, 2008

    8 Huda W, "Technique factors and image quality as functions of patient weight at abdominal CT" 217 : 430-435, 2000

    9 Taffoni MJ, "Prospective comparison of indirect CT venography versus venous sonography in ICU patients" 185 : 457-462, 2005

    10 Yankelevitz DF, "Optimization of combined CT pulmonary angiography with lower extremity CT venography" 174 : 67-69, 2000

    1 Kalva SP, "Venous thromboembolism: indirect CT venography during CT pulmonary angiography--should the pelvis be imaged?" 246 : 605-611, 2008

    2 Reichert M, "Venous thromboembolism: additional diagnostic value and radiation dose of pelvic CT venography in patients with suspected pulmonary embolism" 80 : 50-53, 2011

    3 Fujikawa A, "Vascular enhancement and image quality of CT venography: comparison of standard and low kilovoltage settings" 197 : 838-843, 2011

    4 Lee W, "ThreeDimensional CT venography of varicose veins of the lower extremity" 191 : 1186-1191, 2008

    5 Schindera ST, "Thoracoabdominal-aortoiliac multidetectorrow CT angiography at 80 and 100 kVp: assessment of image quality and radiation dose" 44 : 650-655, 2009

    6 Landis JR, "The measurement of observer agreement for categorical data" 33 : 159-174, 1977

    7 Ulas Savas Yavas, "The Interobserver Agreement between Residents and Experienced Radiologists for Detecting Pulmonary Embolism and DVT with Using CT Pulmonary Angiography and Indirect CT Venography" 대한영상의학회 9 (9): 498-502, 2008

    8 Huda W, "Technique factors and image quality as functions of patient weight at abdominal CT" 217 : 430-435, 2000

    9 Taffoni MJ, "Prospective comparison of indirect CT venography versus venous sonography in ICU patients" 185 : 457-462, 2005

    10 Yankelevitz DF, "Optimization of combined CT pulmonary angiography with lower extremity CT venography" 174 : 67-69, 2000

    11 Stein PD, "Multidetector computed tomography for acute pulmonary embolism" 354 : 2317-2327, 2006

    12 Hirsh J, "Management of deep vein thrombosis and pulmonary embolism. A statement for healthcare professionals. Council on Thrombosis (in consultation with the Council on Cardiovascular Radiology)" 93 : 2212-2245, 1996

    13 Oda S, "Indirect computed tomography venography with a low-tube-voltage technique: reduction in the radiation and contrast material dose--a prospective randomized study" 35 : 631-636, 2011

    14 Duwe KM, "Evaluation of the lower extremity veins in patients with suspected pulmonary embolism: a retrospective comparison of helical CT venography and sonography. 2000 ARRS Executive Council Award I. American Roentgen Ray Society" 175 : 1525-1531, 2000

    15 Begemann PG, "Evaluation of the deep venous system in patients with suspected pulmonary embolism with multidetector CT: a prospective study in comparison to Doppler sonography" 27 : 399-409, 2003

    16 Sung Su Byun, "Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography" 대한영상의학회 9 (9): 59-66, 2008

    17 Szucs-Farkas Z, "Endoleak detection with CT angiography in an abdominal aortic aneurysm phantom: effect of tube energy, simulated patient size, and physical properties of endoleaks" 251 : 590-598, 2009

    18 Cham MD, "Deep venous thrombosis: detection by using indirect CT venography" The Pulmonary Angiography-Indirect CT Venography Cooperative Group 216 : 744-751, 2000

    19 Lim KE, "Deep venous thrombosis: comparison of indirect multidetector CT venography and sonography of lower extremities in 26 patients" 28 : 439-444, 2004

    20 Loud PA, "Deep venous thrombosis with suspected pulmonary embolism: detection with combined CT venography and pulmonary angiography" 219 : 498-502, 2001

    21 Menke J, "Comparison of different body size parameters for individual dose adaptation in body CT of adults" 236 : 565-571, 2005

    22 Waaijer A, "Circle of Willis at CT angiography: dose reduction and image quality--reducing tube voltage and increasing tube current settings" 242 : 832-839, 2007

    23 Goodman LR, "CT venography and compression sonography are diagnostically equivalent: data from PIOPED II" 189 : 1071-1076, 2007

    24 Arakawa H, "CT pulmonary angiography and CT venography: factors associated with vessel enhancement" 189 : 156-161, 2007

    25 Goodman LR, "CT of deep venous thrombosis and pulmonary embolus: does iso-osmolar contrast agent improve vascular opacification?" 234 : 923-928, 2005

    26 Schueller-Weidekamm C, "CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings" 241 : 899-907, 2006

    27 구현우, "CT Radiation Dose Optimization and Estimation: an Update for Radiologists" 대한영상의학회 13 (13): 1-11, 2012

    28 Curry TS, "Basic interactions between X-rays and matter, In Christensen’s physics of diagnostic radiology" Lippincott Williams & Wilkins 61-69, 1990

    29 Wintersperger B, "Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose" 15 : 334-341, 2005

    30 Nakaura T, "A low-kilovolt (peak) high-tube current technique improves venous enhancement and reduces the radiation dose at indirect multidetector-row CT venography: initial experience" 35 : 141-147, 2011

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2023 평가 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
    2020-01-01 등재 등재학술지 유지 (해외등재 학술지 평가) KCI등재
    2016-11-15 학회명변경 영문명 : The Korean Radiological Society -> The Korean Society of Radiology KCI등재
    2010-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2007-01-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    2006-01-01 등재 등재후보 1차 PASS (등재후보1차) KCI등재후보
    2003-01-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 1.61 0.46 1.15
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    0.93 0.84 0.494 0.06
    더보기
    해외이동버튼