      Of the valve replacement patients operated between 1983 and June, 1984, 75 patients need more than 60 minutes of aortic cross-clamping time. 42 patients performed single valve replacement [35 MVR, 7 AVR with or without TAP] and remainder needs double valve replacement with or without TAP. The average aortic clamping time was 95.1 minutes. They need 30 minutes more extra-corporeal circulation time than aortic clamping time. The patients were divided into two groups by usage of cardioplegic solution. Group I [n=31] with Bretschneider solution and group II with potassium cardioplegic solution [M.G.H. modification] were analyzed by extra-corporeal circulation data,/CG and Echocardiography findings, and clinical data. There was no difference between two groups in Bivon addition amounts [cc/kg] and E.F. and S.F. by echocardiography, group I need 1 more electrocardioversion to convert sinus rhythm postoperatively. Also no difference could be found in patients whose preoperative C.I. was above 2.0 between two group. But significant postoperative decrease in E.F. was found in group I whose preoperative C.I. was below 2.0. Relatively longer ECC time was also needed in same group. Ischemic changes in ECG and low cardiac output syndrome was, however more prevalent in groupII. As a whole, the clinical data was satisfactory with both cardioplegic solution in clinical practice.
      번역하기

      Of the valve replacement patients operated between 1983 and June, 1984, 75 patients need more than 60 minutes of aortic cross-clamping time. 42 patients performed single valve replacement [35 MVR, 7 AVR with or without TAP] and remainder n...

      Of the valve replacement patients operated between 1983 and June, 1984, 75 patients need more than 60 minutes of aortic cross-clamping time. 42 patients performed single valve replacement [35 MVR, 7 AVR with or without TAP] and remainder needs double valve replacement with or without TAP. The average aortic clamping time was 95.1 minutes. They need 30 minutes more extra-corporeal circulation time than aortic clamping time. The patients were divided into two groups by usage of cardioplegic solution. Group I [n=31] with Bretschneider solution and group II with potassium cardioplegic solution [M.G.H. modification] were analyzed by extra-corporeal circulation data,/CG and Echocardiography findings, and clinical data. There was no difference between two groups in Bivon addition amounts [cc/kg] and E.F. and S.F. by echocardiography, group I need 1 more electrocardioversion to convert sinus rhythm postoperatively. Also no difference could be found in patients whose preoperative C.I. was above 2.0 between two group. But significant postoperative decrease in E.F. was found in group I whose preoperative C.I. was below 2.0. Relatively longer ECC time was also needed in same group. Ischemic changes in ECG and low cardiac output syndrome was, however more prevalent in groupII. As a whole, the clinical data was satisfactory with both cardioplegic solution in clinical practice.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼