RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS KCI등재 SCIE

      PZT/Epoxy (1-3형) 복합재료의 두께변화에 따른 압전특성 = Piezoelectric Properties on the Thickness of Specimens with PZT/Epoxy Composite Materials of 1-3 Connectivity

      한글로보기

      https://www.riss.kr/link?id=A106126919

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      In this paper, piezoelectric composite materials of 1-3 connectivity were prepared by using "dicing-filling" technique with PZT ceramics and epoxy polymers, and the dependence of piezoelectric properties on the thickness of specimens was investigated. In case that the PZT volume percent is 18.1%, according to an increment of thickness, the dielectric constant of composites( 33) is unchangeable, which is about 200, the piezoelectric coefficient (d33) is somewhat increased, which is about 240-280 (PC/N) and the electromechanical coupling factor of thickness mode(kt) is proportioned, but radial mode(kp) is constant.
      번역하기

      In this paper, piezoelectric composite materials of 1-3 connectivity were prepared by using "dicing-filling" technique with PZT ceramics and epoxy polymers, and the dependence of piezoelectric properties on the thickness of specimens was investigated....

      In this paper, piezoelectric composite materials of 1-3 connectivity were prepared by using "dicing-filling" technique with PZT ceramics and epoxy polymers, and the dependence of piezoelectric properties on the thickness of specimens was investigated. In case that the PZT volume percent is 18.1%, according to an increment of thickness, the dielectric constant of composites( 33) is unchangeable, which is about 200, the piezoelectric coefficient (d33) is somewhat increased, which is about 240-280 (PC/N) and the electromechanical coupling factor of thickness mode(kt) is proportioned, but radial mode(kp) is constant.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼