RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • LED 조명을 적용한 사무공간의 조명방식에 따른 적정 환경 설정을 위한 연구

        유영호 충남대학교 대학원 2012 국내석사

        RANK : 248703

        This study categorizes the types of activities carried out in office space in order to attain a pleasant lighting environment and aims to extract an adequate lighting environment for each activity utilizing general and focused lighting methods. The experiment was carried out by constructing a full-size mock-up similar to a typical office space, and used LED surface light sources for the ceiling and working surface lighting that allows the modification of light color and intensity. Experiment Ⅰ used 48 different lighting intensities for 3 activity types (non-work, general work and precision work) with 18 participants measured through a subjective 7-scale survey. As a result of the experiment, for non-work activities, color temperature of 4,700K~5,200K with 450~500㏓ light intensity proved to be optimal. Also, for general work, color temperature of 4,700K~5,600K with 750~800㏓ light intensity, and for precision work, 5,200K~5,600K with 850~1,000㏓ was extracted as optimal setting. If a ceiling light(general lighting) that was able to adjust light intensity and color temperature was used, the results of this study can be applied for applicable work type. In experiment II the optimal lighting for LED light's focused/general interchangeable lighting in office space was extracted. General and precision work types were experimented where a work surface lighting creates the lighting environment. A total of 25 lighting environments per activity was tested and used the results from experiment I for ceiling lighting. As like in experimentⅠ, a subjective 7-scale was used to measure the results and there were a total of 20 participants. As a results to experiment Ⅱ, in case of general work, ceiling lights from 4,700K and 470㏓ with work surface lights with 5,600K and 770㏓ to 4,700K with 630㏓ and working surface of 5,200K with 770㏓ was extracted. During precision work, ceiling lighting at 4,700K with 470㏓ and work surface lighting of 5,200K with 980㏓ was extracted as optimal. The preference towards ceiling light was concentrated on 4,700K with 470㏓ for both general and precision work. The results of this experiment suggest that in a non-work activity, a general lighting of 4,700K with 470㏓ intensity through a ceiling light should be used and for general or precision work, focused lighting (work surface lighting) should be used along with general lighting. And the results extracted can be used as a standard to set the color temperature and light intensity. From the above research results, a work environment built considering the intensity, color temperature and lighting type, a more pleasant and efficient work environment can be set up compared to the conventional fluorescent lighting. The results can also be a guide to setting up lighting in the office space using LED. Also, by utilizing high-efficiency LED light sources and focused/general range lighting together, an efficient lighting environment can be set up to save energy and tackle some of the environmental issues at hand. 본 연구는 사무공간에서의 쾌적한 조명환경 설정을 위하여, 사무공간에서 이루어지는 행위 유형을 분류하고, 일반적으로 적용되는 전반 조명방식과 국부·전반 병용 조명방식에 대한 각 행위 유형에 따른 적정 조명환경을 추출하고자 연구를 진행하였다. 연구의 실험은 보편적인 사무공간 환경과 유사한 실물대모형(Mock-up)을 제작하여 실시하였으며, 천장 및 작업면 조명기구는 색온도 및 조도의 조광(調光)이 가능한 LED 면광원으로 선정하였다. 실험Ⅰ은 전반 조명방식에 대한 적정 조명환경 추출을 위해, 비작업 행위, 일반작업 행위, 정밀작업 행위의 3가지 유형에 따라 천장조명의 48가지의 조명량을 변인으로 하여 피험자 18명을 통해 7단계 주관적 척도법으로 실험이 진행되었다. 실험의 결과, 비작업 행위에 대하여는 4,700K~5,200K의 색온도에서 450~500㏓의 조도를 갖는 조명량이 적정 조명환경으로 추출되었다. 또한, 일반작업 행위에 대하여는 4,700K~5,600K의 색온도에서 750~800㏓의 조도를 갖는 조명량이, 정밀작업 행위에 대하여는 5,200K~5,600K의 색온도에서 850~1,000㏓의 조도를 갖는 조명량이 적정 조명환경으로 추출되었다. 조도와 색온도의 조광이 가능한 천장조명(전반 조명)을 사용하여 해당 작업에 적정한 조명환경을 구축할 수 있는 조명방식을 적용할 경우 본 실험의 결과가 적정 기준이 될 수 있을 것이다. 사무공간에서 LED조명의 국부·전반 병용 조명방식의 적정 조명량 추출을 위한 실험Ⅱ에서는, 작업면 조명에 의해 조명환경이 이루어지는 일반작업 행위와 정밀작업 행위의 2가지 유형에 대하여 실험이 이루어졌다. 행위 유형별 25가지의 조명환경으로 실험이 진행되었으며, 천장조명은 실험 Ⅰ의 도출값을 적용하였다. 실험Ⅰ과 마찬가지로 7단계 주관적 척도법을 통해 실험이 진행되었으며, 피험자는 20명이다. 실험Ⅱ의 결과, 일반작업 행위 유형에서는 천장조명 4,700K의 470㏓에서 작업면 조명량 5,600K의 770㏓의 조명환경과 천장조명 4,700K의 630㏓에서 작업면 조명량 5,200K의 770㏓의 조명환경이 적정 조명환경으로 추출되었다. 정밀작업 행위에서는 천장조명 4,700K의 470㏓에서 작업면 조명량 5,200K의 980㏓의 조명환경이 실험결과로 가장 적당한 것으로 나타났다. 천장조명에 대한 선호도는 일반작업과 정밀작업 모두 4,700K의 470㏓에 대한 선호도가 가장 높게 나타났다. 본 실험의 결과는 비작업 행위에 대하여는 천장조명만을 이용한 4,700K의 470㏓의 전반 조명방식으로 운영하고, 일반작업 또는 정밀작업을 실시할 경우 조광이 가능한 국부조명(작업면 조명)을 사용하여 해당 작업에 적정한 조명환경을 구축하는 조명방식을 적용할 경우 본 실험의 결과가 적정 기준이 될 수 있을 것이다. 이상의 연구결과로 기존 형광등 조명환경에 비하여 조도 및 색온도, 조명방식을 고려한 작업환경을 구축함으로써, 사무공간의 쾌적성과 함께 작업능률을 올릴 수 있는 조명환경의 설정이 가능할 것으로 판단되며, LED 조명을 이용한 사무공간의 조명환경 설정에 있어서 쾌적조건에 관한 가이드가 될 수 있으리라 생각된다. 또한, 고효율의 LED광원의 사용과 더불어 국부·전반 병용 조명방식을 이용하여 효율적인 조명환경을 운영한다면 에너지 절감 및 환경문제 해결에도 기여할 것으로 사료된다.

      • 조명방식의 지하철 승강장 적용 검토

        김창기 서울産業大學校 鐵道技術大學院 2003 국내석사

        RANK : 248703

        지하철 역사에서의 신조명 방식을 적용(특히 승강장)하기 위하여, 본고에서는 지하철 역사의 조명 특성 및 현황을 살펴보고, 최근의 주요 신조명 방식 몇 가지-무전극 램프시스템, LED 조명 시스템 그리고 광 파이프 시스템-를 점검해 보았다. 그 결과 그 중 현실적인 여건상 바람직한 조명이라고 생각되는 광파이프 조명을 가지고서 현재 일반적으로 우리 지하 역사에 설치된 형광등 조영 방식과 비교/검토해 보았다. 광파이프 국내 공급사에서 입수된 해외적 기술 제안서예 의하면 광파이프 시스템은 형광등 시스템보다도 경제적이고 몇 가지 장점들이 있는 것으로 나타나고 있으나, 또한 제안서와 동일한 방식인 생애주기 비용분석법[LCCBA(Life Cycle Cost Benefit Analysis)]으로 국내의 일반 지하철 역사 승강장에 대해서 조명 경계성 분석을 수행하고, 광파이프 국내 공급사에서 제공한 조명 시뮬레이션 프로그램('Relux' Web site: www.relux.ch)으로써 그들의 도움으로 국내의 일반 지하철 역사 승강장을 조명 시뮬레이션을 해보았다. 그 결과, 1, 광파이프 조명 시스템(프리즘 방식 조명)은 초기 투자가 너무 크고 효율적인 광원이 없어, 현재까지는 형광등 조명보다도 약 2 배정도 고비용이며 2. 원래의 선 조명으로서의 양호한 균제도 특성도 충분히 살리지 못하여 좀 더 발전시켜야 적합해질 것이라고 판단되었다. The purpose of this study is to expedite to use new lighting systems for subway station, mainly platform in Korea. In this paper, characteristics and status of lighting systems for subway station was surveyed. And some kinds of new lighting systems - Electrodeless lamp system, LED lighting system and Lighting pipe system -was reviewed. As a result, the light guide system with prism light guide {seemed to be the most desirable one)was compared with fluorescent lighting system which prevails on indoor lighting system for our subway station. A nice result has expressed on a proposal document for one of N.Y.substation - platform : the light guide system would be an economic one and with many other merits also. To comparing lighting pipe system with fluorescent lighting system for our subway station - platform, an actual data of fluorescent lighting system was collected from existing subway - platform, a computer lighting simulation ( software program 'Relux: www. relux.ch ) for a typical subway - platform was carried out with a help of an exclusive distributer of lighting pipe - TIR( total internal reflection) system and LCCBA( Life Cycle Cost Benefit Analysis ) for lighting economics was performed also. This result shows, 1. Lighting pipe system needs too high capital cost i.e. initial cost. Thus, as for the total life cycle cost, lighting pipe system is at least 2 times expensive than a fluorescent lighting system. 2. The light uniformity of lighting pipe system is not superior to that of a fluorescent lighting system, in our case( height; 3 m, width;6 m ). Therefore, to promote the use of new lighting system more, we suggest that lighting institutes and makers should develop/supply cheaper lamp system, and a lighting industry and an academy should develop/advance lighting design program and education program for a new lighting system continuously.

      • 가로경관 조명설계를 위한 건축물 외관유형과 경관조명방식에 관한 연구

        김미연 연세대학교 생활환경대학원 2003 국내석사

        RANK : 248702

        우리가 살고 있는 현대 도서공간은 인공구조물로 구성되고 계획되어진 삶의 공간이라고 할 수 있다. 보도를 걷는 동안 가로경관의 단일성은 없고 각 건축물과 거리가구들은 그 자신만의 디자인을 가지고 있다. 그러한 건축물의 외관 조명설계는 그 건물의 용도와 특성, 주변 환경과의 조화를 고려하고 조명의 개념을 명확히 해야 한다. 각 건축물의 특징은 그 형태와 형태를 중심으로 한 여러 수직, 수평 요소들로 결정되며, 주간에 이들 요소들은 그림자, 표면구조, 재질감 및 색채등에 의해 강조되는 한편, 야간에는 어둠 속에 감춰지거나 조명의 영향으로 최적의 상태로 부각시킬 수 있다. 디자이너의 입장에서 전문지식을 갖추지 않은 경우 경관조명설계의 적절한 실행이 어렵고, 넓은 범위의 분야의 각각의 입장에서 조명의 목적을 만족시키기 위한 학문적인 체계와 기준이 필요하다. 오늘날 실무에서 자리 잡고 있는 컴퓨터의 활용으로 경관조명 설계과정 중에서 컴퓨터를 이용한 시뮬레이션은 가상의 상황 분석을 통해 시행착오를 줄이게 하고 시간관 비용을 절감할 수 있다. 이러한 연구의 배경 하에 본 논문에서는 도시의 가로경관을 규정짓는데 중요한 역할을 하는 소규모 상업건축물의 외관유형을 분석하여 감성어휘에 따른 건축물 외관 유형과 경관조명방식의 상관관계를 연구하였다. 본 연구의 2장에서는 문헌고찰을 통하여 경관조명과 가로경관 및 건축물에 대한 일반적인 고찰을 하고, 경관조명의 국내, 외 사례조사 및 가로 건축물의 경관조명에 대한 일반적인 사항을 파악하였다. 3장에서는 경관조명설계 시 컴퓨터 시뮬레이션 과정에 앞서 이루어져야할 하나의 방법론으로 건축물의 외관 유형별 분류와 경관조명방식의 분류과정을 제시하였다. 또한 경관조명의 평가요소에 관한 선행연구를 통하여 소규모 상업건축물의 경관조명에 대한 심리적 평가요소를 도출하였다. 4장에서는 선정된 조사대상 상업건축물의 경관조명이미지를 통하여 도출된 주관적 심리 평가항목으로 설문조사를 실시하였고, 그 결과 일반사항의 분석, 슬라이드별 건축물의 조명방식분석, 다중비교분석, 차원분석, 건축물 외관유형별 조명방식의 분석을 통하여 소규모 상업 건축물의 외관유형과 조명방식의 상관관계를 파악하였다. 마지막으로 5장에서는 건축물 외관유형의 감성어휘를 통한 조명방식의 상관관계 모델을 제시하였다. 그 결과 소규모 상업 건축물의 경관조명은 건축물 외관 유형에 따라 그 강조부위와 연출기번이 다양하였고, 특히 표면의 형태와 개구부에 따른 입면유형 및 마감재의 재질에 의해 나타나는 특성이 관찰자로 하여금 느끼는 감성적 측면에 큰 영향을 미친다는 결론을 도출하였다. 훌륭한 외부조명은 사람들이 도시환경을 대하는 방식에 있어서 긍적적인 역할을 하며, 우리 주변의 건축물들을 미적으로 부각시킬 수도 있고 지역의 정체성 및 안전, 시민으로서의 자존심을 높일 수 있는 한편 거리나 광장, 공원 등 가로공간이 활기를 느낄 수 있게 하는 중요한 요소임이 분명하다. 또한 요즘 들어 조명방식에 있어서 인간 생활 속에서 감성적인 면을 최대한 고려한 기법이 요구되고 있다. 이상과 같이 본 연구에서 제시한 건축물 외관 유형의 분류와 경관조명방식의 분류체계가 조명설계 시 유용하게 활용될 수 있으며, 연구의 과정이 경관조명설계에 있어서 하나의 방법론을 제시할 수 있다고 사료된다. 또한 건축물 외관유형의 감성어휘를 통한 조명방식의 상관관계 모델을 바탕으로 컴퓨터 시뮬레이션의 자료화하여 디자이너 입장에서 다양하고 빠른 결과물을 예측 할 수 있는 도구로 활용되기를 기대한다. We are living in modern cities planed for places with artificial structures. Rarely seen are the same structure of streetscape and every fixture in the street has its own style and design. For lighting design in such diverse structures needs lots of considerations, such as use and characteristics of the structure, harmony with its surroundings, and the function and type of lighting to be installed. The structural characteristics is determined by its shape and several vertical and horizontal factors based on the shape, which can be focused on at day time by shading, the surface structure, the quality of the surface and the color. On the other hand, they can be at night hidden in the darkness or enforced strongly by the effect of the lighting. If a designer doesn't have special knowledge about lighting, it is difficult to carry out exterior lighting design appropriately. It is necessary to have scientific systems ans criteria to fulfill the various purposes in many areas. And also, with the practical use of the computers, computer simulation used in the process of exterior lighting design can be a help to save time and money and to reduce the trial and error by analyzing hypothetical conditions. In this paper, correlation between the ways of lighting and building facade types according to vocabularies for sensitivity is explored based upon an analysis of building facades for small-scale commerce with plays an important role in cityscape lighting design. In the second part of this paper, general aspects of exterior lighting, streetscape and building facades are investigated. Also, domestic and overseas cases of exterior lighting, and general matters on exterior lighting of street buildings are presented. In the third part, categorization of building facade types and the classification process of exterior lighting methods are considered to be carried out before the computer simulation process when the exterior lightings is planned. And also, through the preceding study the evaluation factors about exterior lighting, psychological evaluation factors about the exterior lighting of the small-scale commercial buildings are identified. In the fourth part, a survey is conducted with the subjective psychologic evaluation items which come out from the exterior lighting images of the screened object commercial buildings, and as a result, the correlation between the type of small- scale commercial buildings' facades and lighting methods becomes clear through the analysis of general items, the different ways of buildings' lighting under the different slides, multiple comparison, dimension and different lighting methods o different building facades. finally in the fifth part, an model for the correlation between the way of lighting and the building facade based on vocabularies for sensitivity is suggested. the result says that the lighting of the commercial building has variable effects and focused parts according to the facade type, and especially that factors such as the figure of surface, types of shape in the opening space and the quality of surface largely affect the feeling of viewers. A wonderful exterior lighting palys a positive roll affecting the way people look toward the city landscape, brings buildings into relief aesthetically, guarnatees the community identity, security and pride among the citizen, and gives liveliness to streets, squares, parks and so on. Especially these days, a new way of considering sensitiveness of the human life is required in the lighting plan. With the study above, it is considered that categorization of types of building facades, presented in this article,and the classification system of exterior lighting methods can be useful in planning lighting. And the process of the study is thought to be able to present a method about the exterior lighting planning. Furthermore, computer simulation on the bases of the correlation model of the lighting methods relatd to vacabularies for sensitivity about the building facade types is expected to be data and means which can be a great help for designers to predict various results quickly.

      • 낮은 조명방식 도로환경에서 운전자의 시인 능력 평가 연구

        석대일 강원대학교 대학원 2011 국내박사

        RANK : 248702

        The road lighting is an essential facility in order to ensure the safety of roadway users and well visibility. Typically, the lighting system that luminaires are mounted at the high pole is used a lot. Recently, the LED road lighting luminaires which are being developed adhere to the pole type lighting system. Accordingly, many LED should be used, and increase of size, heavy weight and others are discussed as problems. From a new perspective, low mounting height road lighting system has been proposed in order to solve the some problems of traditional lighting system. In this research, the driver's visibility under the proposed low mounting height road lighting system was evaluated. Based on the evaluation results, the maximum allowable total illuminance(Eemax) on a plane at the observer's eye was proposed as the performance criteria required to the low mounting height road lighting system. To evaluate the driver's visibility regarding to the different luminance distribution between two lighting system, the effects of disability glare by installation, and the effects of flicker, the experiments were performed over three times. (1) In the first experiment focusing on the difference of luminance distribution, the visibility of the driver was evaluated. Several test conditions with different average luminance, overall uniformity, and luminance contrast were provided, then physiological response was evaluated. Changes in reaction time at each of the facts were analyzed. And the reaction time which was obtained from the each lighting systems was compared with each other. It was confirmed that the visibility under the conditions of low mounting height road lighting was better than the other conditions. The difference of luminance distribution for two lighting systems was verified through the calculation of visibility level. The physiological reaction time under the conditions of low mounting height road lighting was fast. (2) In the second experiment, the disability glare effects due to the veiling luminance were evaluated. Based on the measurement method of TI, illuminance of the observer's eye was given to the subjects, and the changes of luminance threshold which be able to recognize the visual target was evaluated. The disability glare of low mounting height road lighting system was larger than traditional road lighting system. So, allowable total illuminance(Ee) on a plane at the observer's eye was limited to the degree that allowable the effects of disability glare. If the limited illuminance is satisfied, the glare effects from two road lighting systems is almost same. The proposed illuminance is 4 lx, and this value was more strictly limited after third test was performed. (3) In the third experiment, the flicker effects due to the narrow installation spacing of low mounting height road lighting system. The amount of light entering the vehicle was assumed to the illuminance that is provided to the driver. As the illuminance was more increased, the physiological reaction time came to be slow, and unpleasant feeling was increased. As the flicker frequency came to be short, the reaction time was slower and unpleasant feeling was increased. The trend with age was similar, but the reaction time of sixties was slower than that of twenties and the variation width of unpleasant feeling was narrow in case of sixties. When the illuminance on the surface of the pupil is low, the reaction time was faster than the reaction time obtained from the pole type road lighting system of the first test. There was a point that the unpleasant feeling was increased and the reaction time became to be slow. The given illuminance(Ee) in this time was proposed as the maximum allowable total illuminance(E_(emax)) on a plane at the observer's eye so that decrease of visibility and unpleasant feeling can be allowed from the low mounting height road lighting system. When the installation spacing is 1 m, the maximum limited illuminance is 1.8 lx, and it is 3 lx at the spacing of 0.5 m. These values are not applied for each of the luminaires, but they are the illuminance on a plane at the observer's eye that will be provided from all luminaires to drivers. If the proposed illuminance is given, an insurance of the driver's visibility will be ensured. Experiments are performed in the indoor laboratory. Variations of visibility due to the factors affecting driver's visibility were analyzed. Based on the results obtained from the traditional road lighting conditions that give the well road lighting environment and the visibility, relative evaluation was performed. To provide the visibility similar with traditional road lighting, the limited illuminance of low mounting height road lighting system was proposed. 야간에 도로 이용자들의 안전을 보장해주고, 양호한 시인성을 확보해 주기 위해서는 도로조명이 필수이다. 근래, LED를 이용한 도로조명기구가 개발되고 있지만, 기존의 조명방식을 고수함으로써 몇 가지 문제점을 안고 있다. 최근 다른 관점에서 접근하여 새로운 조명방식인 낮은 조명방식이 제안되었다. 낮은 장착 높이와 좁은 간격으로 설치되기 때문에 기구마다 많은 광량을 요구하지 않으며, 조도와 휘도, 균제도를 만족시켜주는 것이 용이한 편이다. 본 연구에서는 운전자의 시인성 확보 측면에서, 낮은 도로조명방식과 기존의 등주 조명방식 간의 차이점을 평가하였다. 운전자의 시인성을 보장해주기 위해서, 낮은 조명방식의 기구로부터 운전자의 동공면에 도달하는 조도를 제한하였다. 엄밀한 평가를 하고자 세 가지의 평가 시험을 수행하였다. 실내에 시험실을 구성하였고, 매 시험마다 적절한 평가 방법을 통해서 결과를 분석하였다. 평가 시험들의 결과는 다음과 같다. (1) 1차 시험에서는 노면의 평균휘도, 균제도, 휘도대비에 대한 시인성의 변화를 평가하였다. 노면의 휘도균제도가 더 좋은 낮은 조명방식 하에서 생리적 반응시간이 더 빠른 것으로 나타났다. (2) 2차 시험에서는 동공 표면상의 조도 변화에 대한 휘도식별역의 변화를 평가하였다. 글레어 광원이 시선 축에 가까이 존재하고, 운전자의 동공 면에 높은 조도를 제공한다면, 시대상물을 인지할 수 있는 최소 휘도대비는 두 조명방식 모두 증가하는 것으로 나타났다. (3) 3차 시험에서는 기구 간격, 차량속도, 차량 내로 유입되는 빛의 양에 대한 시인성의 변화를 평가하였고, 심리적인 불쾌감 정도를 평가하였다. 차량 내에 유입되는 빛의 양은 운전자의 동공 면에 제공되는 조도로 가정하였고, 조도가 증가함에 따라 생리적 반응시간이 느려지고, 불쾌감은 증가하는 것으로 나타났다. 플리커 주파수가 낮아질수록 생리적 반응시간이 느려지고, 불쾌감은 증가하는 것으로 나타났다. 위의 결과를 바탕으로 불능글레어의 영향, 플리커에 의한 시인성의 저하와 불쾌감을 모두 허용할 수 있도록 운전자의 동공 면에 도달하는 조도의 최대값(E_(emax))을 제한하였다. 본 연구에서는 운전자의 시인성 확보 측면에서, 두 조명방식 간의 차이점을 평가하고, 낮은 조명방식으로부터 나타날 수 있는 문제점에 대해서 해결 방안을 제시하였다. 양질의 도로조명환경을 보장해준다고 판단된 등주 조명방식의 평가 시험 결과를 기준으로, 이와 유사한 정도까지는 충분히 보장해줄 수 있도록 하기 위한 낮은 조명방식의 기준을 제시하였다. 획일적인 도로조명방식이 아닌 새로운 도로조명방식의 가능성을 보여주고, LED를 이용한 도로조명기구의 또 다른 개발 방향을 제시해 준다는 측면에서 낮은 조명방식에 대한 기대치가 어느 정도 높다고 본다. 향후 낮은 조명방식의 다양한 기구들을 개발하고, 유사한 조명방식을 수용함에 있어서 본 연구 결과가 활용될 수 있을 것이다.

      • 야간경관조명의 조명방식에 따른 평가특성분석

        유재연 忠南大學校 大學院 2002 국내석사

        RANK : 248671

        As the activities of recent modern people expand to night and the demand on the security, pleasantness, and beauty of a city life at night appear, the consideration about not only day but also night is required. Therefore, as the demand on exterior lighting is increased, there are many researches in the exterior lighting domestically. But, the study based on mentality of a man is lacking. So, the purpose of this study is to analyze the characteristics through the evaluation of sensibility according to the type of lighting one of important factors of the exterior lighting based on a building, and present one representative image based on the type of the exterior lighting. For this, this study analyzed the character of the evaluation of sensibility according to the type of lighting of the exterior lighting about a building using a picture and CG(computer graphic) as the evaluation tool of the exterior lighting. The process of the study is divided to 5 steps at large. In the first step, after collecting the examples of the exterior lighting for the evaluation of sensibility according to the type of lighting of the exterior lighting, the vocabulary of the evaluation is selected through the survey and the thesis. Also, through the analysis of examples, I arranged and analyzed the type of lighting. In the second step, the validity of the evaluation tool of the exterior lighting with the vocabulary selected in the first step is verified. The third step, with the experiment of the evaluation of the type of the lighting of the exterior lighting, the vocabulary of the evaluation selected in the first step and the basis of the validity of the verified evaluation tool in the second step, carried out the experiment with the picture and the CG. The fourth step analyzed the relation between the selected representative image and the type of lighting of the exterior lighting about a building quantitatively after analyzing the factors of the result of the experiment of each evaluation. The fifth step presented the representative image according to the type of lighting of the exterior lighting. 1. Verification of validity of the evaluation tool of the exterior lighting In the verification of the physic amount implemented prior to sensibility of the evaluation, the rate of total average relative error was 3.76, and the rate of average relative error of each ramp was within 5%. So, the real test and the verification of physic amount of luminance of the simulation test by CG can be valid. The validity of the result of the evaluation of sensibility of simulation using the real test and the CG showed little difference of regard except the item of 「natural」, 「changable」, 「funny」. The validity of the result of the real test and the evaluation of sensibility of pictures told us nothing to regard except the item of 「natural」, 「cozy」, and 「funny」. 2. Analysis on the character of the evaluation according to the type of lighting of the exterior lighting 1) When the exterior lighting is evaluated, I analysed the factors in order to make sure the construction of mentality. As the result of that, the test of the picture was divided to 4 factors, and the test of the CG is split to 3 factors. But there were only changes of the item of evaluation of 4 factors divided to extra factors of the picture test, and the I of an activity axis as a main factor's axis, the Ⅱ of an evaluation axis, and the Ⅲ of a warmth axis are similar and explainable to both the picture and the CG identically. As the result of the analysis of the factor of the CG test, the first factor consists of the item of evaluation such as 「funny」, 「dynamic」, 「gay」, 「changable」, 「active」, 「intense」, 「clear」, 「characteristic」, 「bright」, 「modern」 and 「rising」 and those are called as the factor [funny · dynamic]. The second factor consists of the item of evaluation such as 「natural」, 「stable」, and 「comfortable」, and those are called as the factor [natural · stable]. The item of evaluation like 「grand」 put aside since it is involved in both the first and second factors. The third factor consists of the item of evaluation such as 「mysterious」 and 「warm」 and those are called as the factor of [mysterious · warm]. 2) The result of the distribution chart of factor scores in order to analyze the character quantitatively through evaluation by the test, the image of [dynamic · gay] shows the high relative relation of the type of lighting between the linear lighting and the transmitted light in the test of a picture, but in CG test, point lighting and linear lighting have high relative relation. And, down lighting and up lighting have low relative relation. The mixture lighting using the type of lighting more than two things has high relative relation. The image of 「stable」 and 「natural」 has high relative relation with the up lighting and the type of transmitted light in the test of a picture, but in CG test, up lighting, down lighting, and transmitted light have high relative relation. And in the case of partly evaluated low on the up lighting and down lighting, the lighting is caused by being set up on the highest part. And the image of 「stable」 and 「natural」 is judged as influenced on the position lighted. The case of the mixture lighting using more than two things, involving point lighting and linear lighting had low evaluation, but the case of the type of transmitted light, up light, and down light intended to show high evaluation. The image of [mysterious · warm] like the test of a picture influenced more than the type of lighting. The warmer color of light is, the higher relative relation is to the item of most warm color, and as much as the color of light is close to cold type and G type, it has high relative relation with the item of 「mysterious」.

      • 서울성곽 경관조명 개선방안에 관한 연구

        이정하 서울시립대학교 2010 국내석사

        RANK : 248670

        최근 야간문화관광산업이 발전되면서 각 도시의 정체성을 나타내는 건축물 위주로 경관조명이 시행되고 있다. 그 중심에는 문화재 경관조명이 있다. 하지만 잘못된 조명계획으로 문화재가 오히려 퇴색되어 보이거나 형태가 왜곡되어 보이는 문제가 발생되고 있다. 이는 문화재가 가지고 있는 고유한 역사적 의의와 문화적 가치가 고려되지 않고 대상지 주변의 환경 분석 및 방문객 이용행태와 경관적 특성 등에 대한 분석이 제대로 이루어지지 않은 야간경관계획의 결여가 가장 큰 원인이라고 판단했다. 따라서 경관조명이 시행된 문화재 중 가장 최근에 경관조명 계획이 시행된 서울성곽을 대상으로 문제점을 분석하고 원인을 찾아 이에 대한 개선방안을 제시하고자 했다. 서울성곽은 18㎞라는 거대한 규모를 지니고 있고 산세를 따라 위치해 유기적으로 변화하는 선형의 리듬감을 가지며 시대별 축성과 복원의 변천과정을 온몸으로 증명하고 있다. 따라서 서울성곽은 600년 역사도시 서울을 대표하는 역사 ․ 문화 경관이다. 이러한 서울성곽도 2005년 성북지구를 시작으로 연차별계획을 통해 2009년 현재 전 지구에 걸쳐 경관조명이 설치되었다. 하지만 설치가 된지 얼마 안됐는데 대부분의 지구가 소등을 하고 있고 점등을 하고 있는 구간도 원경에서는 보이지 않는 등 조명의 효과가 떨어진다. 원인으로는 에너지 낭비로 인한 소등 및 복원구간에 접해 소등한 구간, 조경 식재에 따른 소등 등 다양하지만 이러한 문제에 대해 대처하지 못하는 야간경관계획에 검토하고 대안점을 모색해보고자 했다. 서울성곽 경관조명 개선방안 관한 연구로 근경, 중경, 원경에서 보이는 지구별 조명 특성을 조망점 조사를 통해 알아보아 우수조망경관 4개의 대상지를 선정했다. 문화재 전문가와 서울성곽 해설가, 경관조명 디자이너 등 각 분야의 전문가와 인터뷰를 통해서는 문화재 경관조명 시에는 안전성을 확보한 상태에서 문화재의 역사적 ․ 문화적 특성을 부각시켜야 하고 현재의 서울성곽은 밝아서 빛의 밝기가 조정되어야 하며 성곽은 선형의 연속성이 강조되어야 한다는 점을 알 수 있었다. 이용시민 의식조사를 통해서는 시민들은 대체로 만족도를 보였으나 빛색상과 눈부심 등은 문제점으로 지적하였다. 서울성곽의 빛 분포 특성을 분석하기 위해 4개의 지구별로 야간의 특성을 휘도, 휘도대비, 색온도를 중심으로 주 ․ 야간 현장조사를 통해 조명물리량과 현재의 경관 모습과 조명설치 현황을 살펴보았다. 또한 대상지의 조도, 휘도와 주변경관의 휘도를 측정하는 광측정 조사를 수행하여 경관의 빛 구성요소들을 휘도 대비해 각 지구별의 빛환경 특성을 알 수 있었다. 삼청지구는 나트륨 150W, 메탈 150W로 지중조명과 전면투광조명으로 이루어져 색온도와 연색성의 차이로 선형으로 연결이 안 되며 산책로에 눈부심을 형성하고 있다. 또한 평균휘도 6.6nt로 주변경관보다 10배 이상의 휘도차를 가지지만 주변 가로등 빛에 의해 원경과 중경에서 바라보는 조명 효과가 떨어지고 있다. 장충지구는 성곽의 축성특성이 부각되며 근경에서 조망되는 경관으로 메탈 70W 지중등으로 상향 조명되어 있고 색온도는 3000K, 연색성은 Ra 80, 평균휘도는 4.3nt로 적정한 밝기이지만 주변 가로등 빛에 의해 조명 효과가 상쇄되고 산책로에 강한 눈부심을 형성하고 있다. 또한 성곽의 중심부까지만 조명효과가 나타나는 문제를 지니고 있다. 남산지구는 내성과 외성이 모두 조망되는 경관으로 조명방식과 적용기구의 종류도 다양하다. 따라서 색온도가 1950K~4000K대 까지 다양하고 외성보다 내성의 휘도차가 크고 밝아서 주변에 빛광해를 형성하고 있다. 청운지구는 나트륨 150W, 메탈 150W로 지중조명과 전면투광조명으로 이루어져 색온도와 연색성이 차이나며 빛 패턴이 형성되어 전체적인 선형이 부각되지 못하고 있다. 성곽의 평균휘도는 6.25nt, 10.91nt이나 주변하늘이 2.531nt를 나타내는 등 산란되는 빛의 양이 많았다. 서울성곽 야간경관에 대한 개선방안으로는 크게 두 가지로 지구별 조망 특성을 고려한 성곽조명과 빛의 양보다는 질을 고려한 계획이다. 각 지구별 근 ․ 중 ․ 원경에서의 조망경관을 분석해 우수조망권에 따라 성곽의 조명 방식에 차별화를 둔다. 원경조망 지구는 성곽의 상부를 강조하는 조명을 계획하고, 중경조망 지구는 광량이 적은 광원을 적용하고 최대한 주변의 가로등이나 폴을 이용하여 조명기구 노출을 최소화 하도록 한다. 근경조망 지구는 성곽의 특성을 부각시키기 위해 지중조명 상향조사방식을 적용하지만 눈부심을 차단하기 위해 현장에 따라 적정한 악세서리를 설치하도록 한다. 빛의 양보다는 질을 고려하는 방안으로는 성곽주변의 모든 가로등을 컷오프형으로 교체하고 고효율의 광원과 조명기구를 선정하여 에너지 효율을 높이도록 한다. 또한 대상의 조명효과를 높일 수 있는 색온도와 연색성을 고려해 선정해야 하고 계획 시 조도 ․ 휘도 계산 프로그램을 통해 충분한 시뮬레이션을 검토하도록 한다. 그 다음은 설치 후 회로구분과 디밍연출이 가능한 조광제어를 통해 다양한 연출효과를 계획할 수 있다. 조사대상지인 4개 지구별 경관조명 개선방안을 제시하였다. 삼청지구는 원경과 중경에서의 조망이 우수하기 때문에 북악산의 스카이라인을 부각시키는 조명계획을 수립한다. 시대별 축성 특성보다는 전체적인 성곽의 선형을 강조하기 위해 3000K, Ra80이상의 광원 메탈 35W와 70W를 이용해 월-워싱 조명하여 평균계획 휘도 1nt가 되도록 한다. 장충지구는 성곽 축성양식의 보존상태가 가장 양호한 지구로 이러한 특성을 부각시키는 조명계획을 수립한다. 빛의 음영 표현으로 세종 축성시의 요철감을 부각시키기 위해 3000K의 고휘도 Line LED 18W 지중등으로 상향조명하여 낮은 광량으로 하부에서 상부까지 고르게 빛이 전달될 수 있도록 계획하고 악세서리를 적용해 눈부심을 차단한다. 남산지구는 N타워 상부에서 조망 시에 성곽의 전경을 조망할 수 있기 때문에 전체적인 성곽의 골격이 부각될 수 있는 조명계획을 수립한다. 시민 또는 관광객의 방문이 많아 성곽이 쉽게 조망되며 타워산책로를 따라 방문객에게 유인 및 방향성의 성격을 지닌다. 따라서 원경과 근경에서의 조망을 고려하여 내성과 외성의 조명방식을 상향조명방식과 월-워싱 조명으로 달리하되 색온도와 연색성은 동일하게 연출하도록 한다. 청운지구는 인왕산 등산로에서 바라보는 중경이 우수하므로 성곽의 선형을 살리는 조명계획으로 월-워싱 조명방식으로 성벽면이 고르게 연출될 수 있도록 하고 색온도 3000K과 연색지수 Ra 80이상의 메탈 광원 35W, 70W를 사용해 평균 계획휘도 1nt가 되도록 계획한다. 본 연구의 지구별 개선방안은 4개 지구 성곽 조사 결과 치를 바탕으로 한 것이기 때문에 모든 대상에 일반화하기에는 무리가 있으며, 휘도의 경우에는 대상에 따라 시각으로 보는 휘도 치와 측정하는 휘도 치의 오차가 있을 수 있으며 방향과 거리 등의 변수가 많다. 하지만 서울성곽 경관조명 보완 또는 다른 성곽에 대한 야간경관을 계획 시에는 문제점 및 보완책 등을 고려해서 적용 기준과 조명방식 등을 활용할 수 있을 것이라고 기대한다.

      • 建築物의 景觀照明 評價方法에 관한 硏究

        최영준 延世大學校 大學院 2000 국내박사

        RANK : 248670

        국제적으로 높아진 위상에 걸맞게 우리나라 도시의 이미지는 새롭게 개선될 필요가 있다. 지금까지의 도시모습이 성장 일변도에서 도시구조의 개발과 확장에 힘써왔다면 이제는 도시의 모습을 가꾸어 가는 데 중점을 두어야 한다. 도시의 모습이 아름답고 독창적인 모습으로 거듭날 때 이미지가 높아질 것이며 이러한 관점에서 경관조명의 활성화는 도시 야간경관의 획기적인 변화를 가져오는데 이바지 할 것이다. 이와 같은 연구배경 하에서 본 논문에서는 건축용도별 경관조명 디자인에 대한 체계적이고 객관적인 평가방법의 제시와 그 검증에 관하여 연구하였다. 본 연구의 2장에서는 건축물의 경관조명에 관한 역사와 기준 등 일반적 고찰을 한 후, 국내외 경관조명에 대한 사례를 조사하였다. 3장에서는 경관조명의 디자인 프로세스, 평가 등에 관한 선행연구 분석과 전문가 면접조사를 통하여 건축물의 경관조명 예비 평가요소들을 도출하였다. 다음으로 4장에서는 예비 평가요소들에 대한 전문가 대상 설문조사를 실시하여 그 결과를 상관분석, 분산분석, 인자분석 등의 통계분석방법을 이용하여 분석하고, 고건축물, 사무소 건축물, 상업 건축물에 대한 각각의 건축용도별 경관조명 평가방법을 제시하였다. ① 고건축물의 경관조명 “예술적 가치”, “흥미/ 관심”, “완성도”, “적정 광원 사용”, “빛의 질”, “적정 조도/ 휘도량”, “현휘(휘도비)”, “인지도”, “경관 기여도”, “이해”를 중심으로 평가하여야 한다. ② 사무소 건축물의 경관조명 “흥미/ 관심”, “조형미”, “독창성”, “경관 기여도”, “인지도”, “입체적 표현”, “빛의 질”, “적정 조도/ 휘도량”, “현휘(휘도비)”, “광공해 유무”, “용도 반영”을 중심으로 평가하여야 한다. ③ 상업 건축물의 경관조명 “조형미”, “완성도”, “색조 분포”, “인지도”, “독창성”, “용도 반영”, “광공해유무”, “현휘(휘도비)”, “친밀감”, “시각적 즐거움”, “흥미/ 관심”을 중심으로 평가하여야 한다. 이상과 같은 경관조명 평가방법 중에서 특히, “흥미/ 관심”, “현휘”, “인지도” 항목은 건축용도에 무관하게 공통적인 중요항목으로 나타났으므로 가장 중점적으로 고려되어야 할 사항들로 판단된다. 마지막으로 5장에서는 건축용도 중 도시경관에서 차지하는 비중이 크고 각 지역에서 렌드마크적인 역할을 하는 사무소 건축물로 평가대상을 한정하고, 이에 대한 평가방법의 검증을 위해서 서울 소재인 10개 사무소 건축물의 경관조명을 대상으로 슬라이드 사진에 의한 평가를 실시하였다. 그 결과를 회귀분석을 통해 검증한 결과, 앞서 제시된 건축용도별 경관조명의 평가방법이 타당하다는 결론을 도출하였다. 건축물의 경관조명으로써 관찰자로 하여금 흥미/ 관심을 일으키고 건물의 인지도를 높이기 위해서는 조명방식별 평가결과처럼 전반적인 조명을 하되 색채변화나 수직강조로써 변화를 주는 방식이 바람직하다고 판단된다. 다만 아무리 강조가 필요하더라도 10 : 1 이상의 강한 휘도비는 억제되어야 하며 2 : 1 ∼ 3 : 1 정도의 휘도비를 유지하여 현휘 및 주변환경에 대한 광공해를 방지해야 할 것이다. In accordance with the prestige image that our country has built recently, our images of cities need to be improved. Until this point our focus has been on development and expansion of our cities, whereas now, we need to concentrate on shaping our cities. As the cities become beautiful and unique, the image of the city will be improved and from this point of view, activation of exterior lighting will result in drastic improvement of a city's night view. In this study, the author suggested and test a systematic and objective evaluation method of exterior lighting according to the usage of buildings. In chapter 2 of this study, the author performed a general review on the history and standards of exterior lighting and investigate foreign and internal cases of building exterior lighting. In chapter 3, the author analysed preceding studies on the design process and evaluation of exterior lighting, and derive pretest evaluation elements though interviews with specialists in lighting design. In chapter 4, the author performed interviews based on the pretested elements and perform statistical analyses including correlation analysis, analysis of variance, and factor analysis, and suggest an evaluation method of exterior lighting in antique buildings, office buildings, commercial buildings. ① Exterior Lighting of Antique Buildings It should be appraised according to "Artistic Value", "Interest/Anxiety", "Completeness", "Use of Appropriate Light Source", "Quality of Light", "Appropriate Illumination/Brightness", "Glare (Brightness Ratio)". "Recognition", "Contribution to City's View", "Understanding". ② Exterior Lighting of Office Buildings It should be appraised according to "Interest/Anxiety", "Beauty of Form", "Uniqueness", "Contribution to City's View", "Recognition", "Three Dimensional Expression", "Quality of Light", "Appropriate Illumination/ Brightness", "Glare (Brightness Ratio)", "Existence of Light Pollution", "Reflection of Use". ③ Exterior Lighting of Commercial Buildings It should be appraised according to "Beauty of Form", "Completeness", "Color Distribution", "Recognition", "Uniqueness", "Reflection of Use", "Existence of Light Pollution", "Glare (Brightness Ratio)", "Friendliness", "Visual Pleasure", "Interest/Anxiety". Among the evaluation methods, "Interest/Anxiety", "Glare (Brightness Ratio)", and "Recognition" are important elements regardless of the use of the buildings, and must be focused. Finally, in chapter 5, the scope of this study was limited to office buildings that are landmarks to the area and play a significant role in the city's view. For this study, office buildings were photographed at night with slide films and shown. Through a regression analysis, the author found that the above suggested evaluation method according to the use of the buildings were proper. To promote interest and recognition of a building ambient lighting should be done as shown in the results of this study, however variability through color variation and vertical accent is preferred. Despite the need of emphasis brightness ratio exceeding 10:1 must be avoided and glare and light pollution must be prevented through maintaining a 2:1∼3:1 brightness ratio.

      • 대학캠퍼스 조명디자인 가이드라인에 관한 연구 : 건국대학교 서울캠퍼스 조명디자인 가이드라인을 중심으로

        장링연 건국대학교 대학원 2014 국내석사

        RANK : 248670

        현대사회는 고속 발전하고 있는 데 사람들은 생활 속에서 각양각색의 야간조명방식을 사용한다. 조명은 다른 사람에게 좋은 이미지를 직접 보여줄 수 있는 동시에 주변 야간환경도 미화시킬 수 있다. 옛날의 조명이 단지 안전을 위해서 만들었다면 지금은 아니다. 아름다운 조명이 사람의 생활에서 무척 중요한 일부분이 된다고 볼 수 있다. 대학 캠퍼스조명도 마찬가지다. 비록 조명디자인의 기술이 예전보다 많이 변화하고 진보했지만 이런 변화들을 눈여겨봄으로써 어떤 부족한 점도 있는 것이다. 본문의 주제는 대학캠퍼스 조명디자인 가이드라인에 관한 연구할 뿐만 아니라 건국대학교 조명디자인 가이드라인을 중심으로 연구한다. 위에서 말했듯이 도시의 빛의 설계는 왕성히 발전하고 있다. 다른 편으로 많은 조명디자이너들이 도시의 야간조명의 진보를 위해 노력하고 있다. 최근 몇 십 년에 제 3의 기술 혁명을 의지하여 우리 주면의 환경이 예전보다 천지가 뒤집힐 정도로 대변하였다. 사림들이 단일한 생활 방식에서 뛰쳐나오기 시작하고 있다. 그러므로 사람들이 주변의 거주환경에 대한 관심을 가지고 있음에 따라 도시야간조명도 어떤 지위를 차지하게 되었다. 사람들이 다시 자신의 주변의 조명 환경을 살펴봤을 때 도시조명의 구멍과 부족점도 조금씩 사람에게 발견되었다. 때문에 사람들이 주변 환경 조명에 대한 요구에 많아지고 있었다. 여기부터 각양각색의 조명 설계가 계속해서 도시의 방방곡곡에 부여하고 있게 할 뿐만 아니라 지속적으로 완성하고 있다. 비록 대학캠퍼스의 조명디자인과 도시 조명다자인을 비교하면 자신의 다른 점이 있지만 도시 조명디자인에 속하기 때문에 대학캠퍼스의 조명디자인도 도시의 발전함에 따라 진보해야 된다. 그러나 지금까지 대학 캠퍼스 조명디자인의 전체적인 가이드라인이 상당히 부족하다. 많은 대학교는 단지 안전을 목적으로 설계하는 사고방식에 머물렀다. 야간 캠퍼스 문화와 경관의 표현 및 전교의 사람의 감각을 소홀히 하였다. 그러므로 대학캠퍼스의 야간조명의 개선을 위하여 새로운 가이드라인을 제출하는 것은 조금도 지체 없이 디자인해야 한다. 본문은 더 아름다운 대학캠퍼스의 조명 방식을 만들기 위해서 대학캠퍼스 조명예술을 연구대상으로 선택하였다. 또한 원래의 방식을 바탕으로 대학 문화, 친환경디자인, 새로운 조명방식 등 환경디자인 수단을 결합하고 다시 분석하여 건국대학교 서울캠퍼스를 중심으로 한 더 풍부한 대학 캠퍼스 조명의 개발을 위해 제안한다. With the high-speed development of the current society, people are choosing various night lighting styles. Lighting can not only give good image directly to other people but also glamorize the surrounding environment at night. Different from that in the old time, the current lighting is produced not limited by the safety. The gorgeous lighting is becoming one of the most important portion in people's life as well as university campus. There are still some insufficient aspects in spite of the great changes happened to the techniques of lighting design. The paper studied on the lighting design guidelines of university campus and focused on it in Konkuk university. The lighting design in cities is in full blast, so many lighting designers are making an effort to the development of urban night lighting. During the recent decades of years, the surrounding environment has changed like overturning the earth and the sky comparing since the third technical revolution. People are running out from the singular lifestyle. As a result, the status of the urban night lighting changed according to people's consideration to the surrounding environment. People found some defects and inadequate aspects of the lighting environment surrounding them when they looked into it. Therefore, people showed more requirements to the lighting environment around them. So, various lighting styles should be granted and got done all over the countries continuously. As the The lighting design in university campus is affiliated to the urban lighting design, it should also be advanced along with the development of that in cities despite of their different points. However, the overall lighting design guidelines of university campus are still quite insufficient. People still pay no attention to the night campus culture and the expressions of landscape and senses of the entire students. Therefore, the new guidelines should be presented without any delay for the improvement of the nighting lighting of the university campus. The purpose of this paper was to make more glorious lighting styles for the university campus and the lighting art of university campus was selected as the object. Based on the original styles, we proposed for the development of more abundant university campus lighting and focused on the Seoul campus of Konkuk University by combining the environment design means, such as the university culture, eco-friendly design, and new lighting styles.

      • 아파트의 照明計劃에 관한 硏究

        엄철수 全南大學校 大學院 1984 국내석사

        RANK : 248654

        住居 生活에 있어서 住環境의 良否는 月常生活과 健康維持에 중요한 요소라 아니할수 없고 住環境중에서 特히 照明環境은 視覺을 좌우하고 人間의 정신 상태, 작업능율 직접시력등에 큰 영향을 미치므로 照明과 人間生活은 밀접한 관계가 있다. 이러한 실정에서 住宅照明의 重要性을 인식하여 주택중에서도 特히 아파트의 照明實態를 調査分析하여 그 문제점을 抽出하고 이를 개선할수 있는 방안을 제시함으로서 우리나라 住宅照明을 개선코자 하였다. 本 硏究의 結果는 다음과 같다. 1. 照明기구는 대부분 형광등이었고 부엌은 백열등을 많이 사용하였으며 조명방식은 거의가 직접조명이나 18평형의 거실부분이 반직접조명이었다. 2. 室의 사용용도는 13평의 경우 居室은 식사, 안방은 화장, 작은방은 공부독서, 15평형은 거실에서 손님접대, 안방은 가족단란, 작은방은 공부독서, 18평형에서는 거실은 손님접대, 안방은 화장, 작은방I, 공부독서 작은방 II는 일일공부 順으로 분석되었다. 3. 대상 아파트의 반사율은 25∼45% 범위였고 대부분 40%정도이며 감광 보상율은 13평형, 15평형은 1.28, 18평형에서는 1.25로서 양호한 상태를 나타내고 있다. 4. 조명기구는 주로 20W 형광등 60W 백열등을 사용하였으나 추장조도를 만족시키기 위해서는 40W 형광등, 100W 백열등을 사용함이 바람직하고 소요 조도 기준이 200Lx 이상인 경우는 국부조명을 병행하여 사용하는 것이 타당하다. 5. 대상아파트 평균조도는 50∼60Lx 이었으나 다용도실만 30Lx 내외였다. 이값은 추장조도기준과 비교하면 부엌은 50%내외였으나 나머지는 30% 내외로서 극히 불량하였다. Living Environment is one of the most improvement element in residence, among which illumination is not only diredly related to visual sense but also affecting the working effieience and psychological tense. That is why illumination is important in residential life. Recognizing the importance of illumination in house the another tries to identify the pro blems of illumination by surveying the presont illumination methods and conditions in apartment house,and to suggest the waz to improve the illuminant condition. The followings are the results, Conclusions are obtained 1. Fluorescont lamps were generably used in apartment house except in kitchen, where Incandescent lamps was inctalled, Direct light system was generally used but Semi-direct light system was used in the living room of 18 Py Apt. 2. The primary content of working perform ence at night was eating at living room, make-up at master's bedroom and study at room in 13 Py Apt, In 15 Py Apt conversation with guest at living room, entertainment at master's bedroom and study at bedroom, In 18 Py Apt,entertainment at living room,make-up at master's bedroom and study at bedroom. 3. The range of surface reflecting ratio was between 25% to 45% (average 40 %). Depreciation factors for the luminaires were 1.28 in 13 Py Apt and 15 Py Apt, But 1.25 in 18 Py Apt. 4. It is recommened that 40 W fluorescent lamps be used insteael of 20 W fluorescent lamps which was generally used. 5. The range of illumination level for surveyed apartment house were between 50 Lx to boLy, but almost 30 Lx at utility room. These Values were very unsufficient comparied with recomm- ened illumination levels, So it is necessary that illumination levels be improved in order to make comfortable lighting environment .

      • 學校建築의 夜間照度에 關한 調査 硏究 : 淸州市內 中·高·大學을 中心으로

        김진철 淸州大學校 大學院 1983 국내석사

        RANK : 248589

        This study was conducted to measure the illumination intensity of various rooms and to compare this result with "The guide line of the standard design for school buildings and facilities" formulated by the Ministry of Education. The illumination intensity of 41 rooms of 25 schools, reading quarters, night study rooms, reading rooms, libraries and practice rooms of vocational schools, was measured by a photoelectric photometer. 1. The average illumination intensity were 73 lux in reading quarters, 83 lux in night study rooms, 92 lux in libraries, 94 lux in reading rooms, and 210 lux in practice rooms of vocational schools. The ratio of the illumination intensity to the standard were 40-59% in reading quarters, and 60-79% in reading rooms, libraries, and practice rooms of vacational schools. 2. Among 41 rooms surveyed, only 3 rooms (7%) met the minimum requirement for illumination while the rest 38 rooms (93%) were not adequate. 3. The reason of inadequate illumination were the maintenance failures and energy saving policy as only 218 lamps in 899 lamps (24%) were lighted. It is suggested that the proper illumination should be provided by furnishing necessary installations and turning on the lights to protect th eyesight of students.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼