VENT가 도재전장 주조관용 비귀금속 합금의 주조성에 미치는 영향에 관한 연구
이진걸,장완식,Lee, Jin-Geul,Chang, Wan-Shik 대한치과보철학회 1985 대한치과보철학회지 Vol.23 No.1
To study the effect of the vent and dense surface of the phophate-bonded investment on the castability of a non-precious alloy used in PFM restoration, one-ended polypropylene straw patterns of 0.15mm thick, 5mm radius. 10mm-high were cast with Vera Bond. The following results were obtained. 1. Thin patterns could be cast completely with a non-precious alloy. 2. No difference in the castability was found among the patterns with vent, chill vent and with out vent. 3. Dense surface of the phosphate-bonded investment had no effect on the cast ability of a nonprecious alloy.
치과 임플랜트 시술시 골천공기구의 회전속도가 주위 골조직의 온도 및 골일체성에 미치는 영향에 관한 연구
이진걸,양재호,이선형,Lee Jin-Geol,Yang Jae-Ho,Lee Sun-Hyung 대한치과보철학회 1992 대한치과보철학회지 Vol.30 No.2
Frictional heat produced by cutting tools during dental implantation procedure may destroy the surrounding bone tissue and regenerative capacity and interfere ossointegration by formation of undifferentiated connective tissue. To study the effect of frictional heat according to various rotational speeds on the regenerative capacity of surrounding bone tissue, 13 ITI HS implants (8 mm) were inserted at 4 mongrel dogs. Temperatures were measured using thermocouple located 6 mm below from the marginal crest and 0.5 mm from the periphery of trephine mill during implant bed preparation. After 4 and 9 months, animals were sacrificed and specimens were examined using x-rays and light microscope. Results were as follows: 1. With drill speeds of 300, 800, 2,000, 3,500 rpm and saline irrigation, temperatures of surrounding bone were decreased from $-2.9^{\circ}\;to\;-1.7^{\circ}C$. Temperature rises of $2.0^{\circ}\;and\;2.1^{\circ}C$ were recorded with a drill speed of 5,000 rpm and irrigation. 2. With drill speeds of 800, 3,500, 5,000 rpm and no irrigation, temperatures of surrounding bone rose from $+1.5^{\circ}\;to\;+6.8^{\circ}C$, but maximum temperature was $40^{\circ}C$ at 5,000 rpm. 3. On radiographic examination, bone resorptions were observed at the upper half of implant of 5,000 rpm without irrigation and one case of 5,000 rpm with irrigation. 4. Osseointegration was unsuccessful in cases of 3,500, 5,000 rpm without irrigation due to fibrous connective tissue formation to the outer surface and hollow, but it was successful in a case of 800 rpm without irrigation. 5. Osseointegration was successful in cases of 300, 800, 2,000 and 3,500 rpm with irrigation. But fibrous connective tissue formation was observed at the hollow of implant inserted with 5,000 rpm with irrigation.