      • The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

        Kim, Jae-Hyun,Lee, Juyoung,Park, Hoon-Hee The Korean Society for Digital Imaging in Medicine 2014 대한디지털의료영상학회논문지 Vol.16 No.2

        Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

      • The Lowest Dose for CT Attenuation Correction in PET/CT

        Kang, Byung-Sam,Son, Jin-Hyun,Park, Hoon-Hee,Dong, Kyung-Rae The Korean Society for Digital Imaging in Medicine 2011 대한디지털의료영상학회논문지 Vol.13 No.3

        PET/CT(Positron Emission Tomography/Computed Tomography) is an examination combining morphological and functional information in one examination. The purpose of this study is to see the lowest CT dose for attenuation correction in the PET/CT maintaining good image quality when considering CT scan dose to the patients. We injected $^{18}F$-FDG and water into the cylinder shaped phantom, and obtained emission images for 3 mins and transmission images(140 kVp, 8 sec, 10~200 mA for transmission images), and reconstructed the images to PET/CT images with Iterative method. Data(Maximum, Minimum, Average, Standard Deviation) were obtained by drawing a circular ROI(Region Of Interest) on each sphere in each image set with Image J program. And then described SD according to the CT and PEC/CT images as graphes. Through the graphes, we got the relationships of mA and quality of images. SDs according to CT graph were 16.25 at 10 mA, 7.26 at 50 mA, 5.5 at 100 mA, 4.29 at 150 mA, and 3.83 at 200 mA, i.e. the higer mA, the better image quality was presented. SDs according to PET/CT graph were 1823.2 at 10 mA, 1825.1 at 50 mA, 1828.4 at 100 mA, 1813.8 at 150 mA, and 1811.3 at 200 mA. Calculated SDs at PET/CT images were maintained. This means images quality is maintained having nothing to do with mA of high and low.

      • The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

        Kang, Hae-Kyung,Kim, Youn-Min,Kim, Hyun-Soo,Lee, Sung-Hee,Cho, Se-Youn,Lyu, Young-Eun,Jung, In-A The Korean Society for Digital Imaging in Medicine 2010 대한디지털의료영상학회논문지 Vol.12 No.2

        The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

      • Investigation About Quality Control of General X-ray System

        Kang, Byung-Sam,Son, Jin-Hyun,Dong, Kyung-Rae The Korean Society for Digital Imaging in Medicine 2011 대한디지털의료영상학회논문지 Vol.13 No.4

        This test is for checking investigation about quality control of general X-ray system in clinic and hospital. We compared general X-ray system of clinic and hospital which are selected freely in the metropolitan area using PMX-III and carried out quality control. Carried out Kilovoltage test, mR/mAs output test, Light filed/Beam alignment test, Half value layer test. Most of test result are appeared that failure rates of clinic is higher than hospital one. Therefore, we should lower failure rates through regular quality control and make environment which can get high quality image.

      • Investigation of Standard Evaluation for the Quality Control of General X-ray Systems

        Kang, Byung-Sam,Son, Jin-Hyun,Kim, Byoung-Jun,Park, Deok-Woo,Jung, Byoung-Hoon,Lee, Hyo-Jin,Hong, Ji-Young,Kim, Seung-Chul The Korean Society for Digital Imaging in Medicine 2010 대한디지털의료영상학회논문지 Vol.12 No.2

        Thanks to the great development of technology in radiation, we are now able to reduce radiation exposure to the patients, and the radiographer and expenses in medical sector. We are also trying to produce ideal images which maintain useful information. These kinds of effort are increasing over the world. For that reason, we should get images which include necessary data of patients. Then it also can help to reduce radiation exposure to the patients. Therefore, we need to know the problems that cause a falling off in image's quality and check on generator in case of their electronic and mechanical errors. And moreover, we should anticipate the possibility of devices errors and prevent them with regular quality control. This investigation was conducted in medical institutions, institute of educations and hospitals. They are all in Seongnam-City. We used PMX-III, kVp meter to implement kVp test, mR / mAs output test, light fiel / beam alignment test, Reproducibility of exposure dose, half value layer test, reproducibility of exposure time test. in the case of hospitals, they perceive the importance of regular quality control and organize the regular quality control team so they can be satisfied with the error standard in most experiments. On the other hand, when it comes to medical institutions and institute of educations, they perceive the importance of regular quality control less than hospitals do. Radiographer need to understand the importance of regular quality control and practice it so they can get the fine ideal image with the lower dose to the patient.

      • The Research about Role Area of RT in Digital Environment - Centers on PACS Workplace -

        Jung, Young-Tae,Park, Bum-Jin,Son, Gi-Gyeong,Jung, Jae-Ho,Kang, Hee-Doo The Korean Society for Digital Imaging in Medicine 2011 대한디지털의료영상학회논문지 Vol.13 No.1

        Now a days in our society, occupation boundaries have become blurred, and come into the limelight in the prior occupation or miss about new workplace. Medical area is no exception also, So we face urgent problem about protecting and spreading RT work-sphere simultaneously. This research allow to identify on RT role area of digital environment that is obscure profession-realm specially, and open up a new field hereafter. We examined present RT role area of digital environment in the more than thirty medical facility(general or university hospital) through questionnaire/visit survey from PACS administrator. Survey sentence comprises total 29 sentence over all main quadrisection-(eX. hospital formation & treatment state and PACS team composition & organization and PACS team workplace and PACS team daily workload), We performed comparative analysis in general contents perspectively. further more, divided main 5 section based on upper analysis and then manufactured output in consideration of each medical facility's operation state. There are comparative problem of hospital policy, So we maintained information security of each facility exhaustively. First, we separated a survey output into main 5 section as follows-(eX. PACS server & maintenance manage, Client/interlock manage, PACS data conversion, 3D reconstruction, PACS data im/export)-that received by 35 medical facility. And then manufactured output with comparative analysis about RT role area each section, general IT managing team about medical environment was out of existence that fill up with RT manpower in the surveyed medical facility consequently. What is worse, hospitals that entirely fill up with another worker were 3 place amazingly. Our specific statistic results show, the respondents was 63% that agree with reorganization of formation base on independence team, and supplement of the personnel average -continuous with upper agreement simply-was about 2.64. Further more, if reorganization break out with only RT manpower, quota TO will increase by geometric progression. Protecting and spreading role workplace is much accounted of the our inevitable project surely and more than 95% PACS administrator's have confidence in this proposition unconditionally. Henceforth, look forward to meeting the RT vision of many-sided multiplayer, based on acquire a specialized IT knowledge actively and open up a new work-field with frontier spirit.

      • Evaluation of Clinical Effectiveness of 3D Digital Endoscopic Image

        송철규,김경섭,김남균,Song, Chul-Gyu,Kim, Kyeong-Seop,Kim, Nam-Gyun The Korean Society for Digital Imaging in Medicine 2002 대한디지털의료영상학회논문지 Vol.5 No.1

        본 연구의 목적은 복강경 수술환경에서 2D와 3D 내시경 비디오 영상이 수술에 미치는 영향을 평가하기 위한 연구이며, 이를 위해 3D 내시경 시스템을 구성하고 성능 평가를 수행하였다. 결과적으로 본 연구에서 제안한 3D 방식이 기존의 전자셔터 방식에 의한 3D 영상에 비해 화질과 시야각이 우수하며, 2종류의 모의 수술 실험 비교를 한 결과, 제안한 방식의 디지털 영상을 이용하는 경우가 성능이 가장 우수함을 정량적으로 확인하였다. This paper represents the design of 3D endoscopic video system in order to improve visualization and enhance the ability of the surgeon to perform delicate endoscopic surgery. Minimally invasive techniques have set new standards in all surgical may experience less post-operative discomfort, shorter hospitalization, and quicker recuperation. Finally, the aim of the present study was to determine the influence of 2D and 3D video imaging on defined tasks on a laparoscopic trainer.