http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
A novel ceramic GEM used for neutron detection
Zhou, Jianrong,Zhou, Xiaojuan,Zhou, Jianjin,Jiang, Xingfen,Yang, Jianqing,Zhu, Lin,Yang, Wenqin,Yang, Tao,Xu, Hong,Xia, Yuanguang,Yang, Gui-an,Xie, Yuguang,Huang, Chaoqiang,Hu, Bitao,Sun, Zhijia,Chen, Korean Nuclear Society 2020 Nuclear Engineering and Technology Vol.52 No.6
A novel ceramic Gas Electron Multiplier (GEM) has been developed to meet the demand of high counting rate for the neutron detection which is an alternative to <sup>3</sup>He-based detector at China Spallation Neutron Source (CSNS). An experiment was performed to measure the neutron transmittance of ceramic-GEM and FR4-GEM at the small angle neutron scattering (SANS) instrument. The result showed the ceramic-GEM has higher transmittance and less self-scattering especially for cold neutrons. One single ceramic GEM could give a gain of 10<sup>2</sup>-10<sup>4</sup> in the mixture gas of Ar and CO<sub>2</sub> (90%:10%) and its energy resolution was about 27.7% by using <sup>55</sup>Fe X ray of 5.9 keV. A prototype has been developed in order to investigate the performances of the ceramic GEM-based neutron detector. Several neutron beam tests, including detection efficiency, spatial resolution, two-dimensional imaging, and wavelength spectrum, were carried out at CSNS and China Mianyang Research Reactor (CMRR). The results show that the ceramic GEM-based neutron detector is a good candidate to measure the high intensity neutrons.
Jiang, Xingfen,Xiu, Qinglei,Zhou, Jianrong,Yang, Jianqing,Tan, Jinhao,Yang, Wenqin,Zhang, Lianjun,Xia, Yuanguang,Zhou, Xiaojuan,Zhou, Jianjin,Zhu, Lin,Teng, Haiyun,Yang, Gui-an,Song, Yushou,Sun, Zhiji Korean Nuclear Society 2021 Nuclear Engineering and Technology Vol.53 No.6
Gadolinium oxysulfide (GOS) is regarded as a novel scintillator for the realization of ultra-high spatial resolution in neutron imaging. Monte Carlo simulations of GOS scintillator show that the capability of its spatial resolution is towards the micron level. Through the time-of-flight method, the light output of a GOS scintillator was measured to be 217 photons per captured neutron, ~100 times lower than that of a ZnS/LiF:Ag scintillator. A detector prototype has been developed to evaluate the imaging solution with the GOS scintillator by neutron beam tests. The measured spatial resolution is ~36 ㎛ (28 line pairs/mm) at the modulation transfer function (MTF) of 10%, mainly limited by the low experimental collimation ratio of the beamline. The weak light output of the GOS scintillator requires an enormous increase in the neutron flux to reduce the exposure time for practical applications.