RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Laminectomy; Laminoplasty; Finite element analyses

        Vicky Varghese,Venkatesh Krishnan,Gurunathan Saravana Kumar 대한척추외과학회 2018 Asian Spine Journal Vol.12 No.3

        Study Design: A biomechanical study. Purpose: A new biomechanical model of the vertebra has been developed that accounts for the inhomogeneity of bone and the contribution of the pedicle toward the holding strength of a pedicle screw. Overview of Literature: Pullout strength studies are typically carried out on rigid polyurethane foams that represent the homogeneous vertebral framework of the spine. However, the contribution of the pedicle region, which contributes to the inhomogeneity in this framework, has not been considered in previous investigations. Therefore, we propose a new biomechanical model that can account for the vertebral inhomogeneity, especially the contribution of the pedicles toward the pullout strength of the pedicle screw. Methods: A bilayer foam model was developed by joining two foams representing the pedicle and the vertebra. The results of the pullout strength tests performed on the foam models were compared with those from the tests performed on the cadaver lumbar vertebra. Results: Significant differences (p <0.05) were observed between the pullout strength of the pedicle screw in extremely osteoporotic (0.18±0.11 kN), osteoporotic (0.37±0.14 kN), and normal (0.97±0.4 kN) cadaver vertebra. In the monolayer model, significant differences (p <0.05) were observed in pullout strength between extremely osteoporotic (0.3±0.02 kN), osteoporotic (0.65±0.12 kN), and normal (0.99±0.04 kN) bone model. However, the bilayer foam model exhibited no significant differences (p >0.05) in the pullout strength of pedicle screws between osteoporotic (0.85±0.08 kN) and extremely osteoporotic bone models (0.94±0.08 kN), but there was a significant difference (p <0.05) between osteoporotic (0.94±0.08 kN) and normal bone models (1.19±0.05 kN). There were no significant differences (p >0.05) in pullout strength between cadaver and bilayer foam model in normal bones. Conclusions: The new synthetic bone model that reflects the contribution of the pedicles to the pullout strength of the pedicle screws could provide a more efficacious means of testing pedicle-screw pullout strength. The bilayer model can match the pullout strength value of normal lumbar vertebra bone whereas the monolayer foam model was able to match that of the extremely osteoporotic lumbar vertebra.

      • KCI등재

        Evaluating Pedicle-Screw Instrumentation Using Decision-Tree Analysis Based on Pullout Strength

        Vicky Varghese,Venkatesh Krishnan,Gurunathan Saravana Kumar 대한척추외과학회 2018 Asian Spine Journal Vol.12 No.4

        Study Design: A biomechanical study of pedicle-screw pullout strength. Purpose: To develop a decision tree based on pullout strength for evaluating pedicle-screw instrumentation. Overview of Literature: Clinically, a surgeon’s understanding of the holding power of a pedicle screw is based on perioperative intuition (which is like insertion torque) while inserting the screw. This is a subjective feeling that depends on the skill and experience of the surgeon. With the advent of robotic surgery, there is an urgent need for the creation of a patient-specific surgical planning system. A learning-based predictive model is needed to understand the sensitivity of pedicle-screw holding power to various factors. Methods: Pullout studies were carried out on rigid polyurethane foam, representing extremely osteoporotic to normal bone for different insertion depths and angles of a pedicle screw. The results of these experimental studies were used to build a pullout-strength predictor and a decision tree using a machine-learning approach. Results: Based on analysis of variance, it was found that all the factors under study had a significant effect (p <0.05) on the holding power of a pedicle screw. Of the various machine-learning techniques, the random forest regression model performed well in predicting the pullout strength and in creating a decision tree. Performance was evaluated, and a correlation coefficient of 0.99 was obtained between the observed and predicted values. The mean and standard deviation of the normalized predicted pullout strength for the confirmation experiment using the current model was 1.01±0.04. Conclusions: The random forest regression model was used to build a pullout-strength predictor and decision tree. The model was able to predict the holding power of a pedicle screw for any combination of density, insertion depth, and insertion angle for the chosen range. The decision-tree model can be applied in patient-specific surgical planning and a decision-support system for spine-fusion surgery.

      • KCI등재

        Comparative Analysis of Effect of Density, Insertion Angle and Reinsertion on Pull-Out Strength of Single and Two Pedicle Screw Constructs Using Synthetic Bone Model

        Venkatesh Krishnan,Vicky Varghese,Gurunathan Saravana Kumar 대한척추외과학회 2016 Asian Spine Journal Vol.10 No.3

        Study Design: Biomechanical study. Purpose: To determine the effect of density, insertion angle and reinsertion on pull-out strength of pedicle screw in single and two screw-rod configurations. Overview of Literature: Pedicle screw pull-out studies have involved single screw construct, whereas two screws and rod constructs are always used in spine fusions. Extrapolation of results using the single screw construct may lead to using expensive implants or increasing the fusion levels specifically in osteoporotic bones. Methods: Single screw and two screw pull-out strength tests were carried out according to American Society for Testing and Materials F 543-07 on foam models to test the effect of density, insertion angle and reinsertion using poly axial pedicle screws. Results: Bone density was the most significant factor deciding the pull-out strength in both single and two screw constructs. The difference in pull-out strength between single screw and two screw configurations in extremely osteoporotic bone model (80 kg/m3) was 78%, whereas in the normal bone model it was 48%. Axial pull-out value was highest for the single screw configuration; in the two screw configuration the highest pull-out strength was at 10°–15°. There was an 18% reduction in pull-out strength due to reinsertion in single screw configuration. The reinsertion effect was insignificant in the two screw configuration. Conclusions: A significant difference in response of various factors on holding power of pedicle screw between single and two-screw configurations is evident. The percentage increase in pull-out strength between single and two screw constructs is higher for osteoporotic bone when compared to normal bone. Reinsertion has no significant effect on pull-out strength in the two screw rod configuration.

      • KCI등재

        Pullout Strength Predictor: A Machine Learning Approach

        Ravi Khatri,Vicky Varghese,Sunil Sharma,Gurunathan Saravana Kumar,Harvinder Singh Chhabra 대한척추외과학회 2019 Asian Spine Journal Vol.13 No.5

        Study Design: A biomechanical study. Purpose: To develop a predictive model for pullout strength. Overview of Literature: Spine fusion surgeries are performed to correct joint deformities by restricting motion between two or more unstable vertebrae. The pedicle screw provides a corrective force to the unstable spinal segment and arrests motions at the unit that are being fused. To determine the hold of a screw, surgeons depend on a subjective perioperative feeling of insertion torque. The objective of the paper was to develop a machine learning based model using density of foam, insertion angle, insertion depth, and reinsertion to predict the pullout strength of pedicle screw. Methods: To predict the pullout strength of pedicle screw, an experimental dataset of 48 data points was used as training data to construct a model based on different machine learning algorithms. A total of five algorithms were tested in the Weka environment and the performance was evaluated based on correlation coefficient and error matrix. A sensitive study of various parameters for obtaining the best combination of parameters for predicting the pullout strength was also preformed using the L9 orthogonal array of Taguchi Design of Experiments. Results: Random forest performed the best with a correlation coefficient of 0.96, relative absolute error of 0.28, and root relative squared error of 0.29. The difference between the experimental and predicted value for the six test cases was not significant (p>0.05). Conclusions: This model can be used clinically for understanding the failure of pedicle screw pullout and pre-surgical planning for spine surgeon.

      • KCI등재

        Identification of Pedicle Screw Pullout Load Paths for Osteoporotic Vertebrae

        Krishnan Venkatesh,Varghese Vicky,Kumar Gurunathan Saravana,Yoganandan Narayan 대한척추외과학회 2020 Asian Spine Journal Vol.14 No.3

        Study Design: A biomechanical study.Purpose: To determine the actual load path and compare pullout strengths as a function of screw size used in revision surgeries using postmortem human subject specimens.Overview of Literature: Pedicle screw fixation has become the standard of care in the surgical management of spinal instability. However, pullout failures are widely observed in osteoporotic spines and treated by revision surgeries using a higher diameter screw, performing cement augmentation, or increasing the levels of fixation. While the peak forces to final pullout are reported, the actual load path to achieve the final force level is not available. Methods: Six osteoporotic lumbar spines (L2–L5) were instrumented with 5.5×40 mm polyaxial screws and loaded along the axis of the screw using a material testing machine according to American Society for Testing of Materials 543-07 test protocol. Tests were again conducted by replacing them with 6.5×40 mm (group A) or 7.5×40 mm (group B) screws. Force-displacement data were grouped and load paths (mean±1 standard deviation) were compared.Results: Pullout strength decreased by 36% when the size of the revision screw was increased by 1 mm, while it increased by 35% when the size of the revision screw was increased by 2 mm compared to the index screw value. While the morphologies of the load paths were similar in all cases, they differ between the two groups: the larger screw responded with generally elevated stiffer path than the smaller screw, suggesting that revision surgery using a larger screw has more purchase along the inserted body-pedicle axis.Conclusions: A larger screw enhances strength and increases biomechanical stability in revision surgeries, although the final surgical decision is made by the clinician, which includes the patient’s anatomy and associated characteristics.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼