        Peak pressures on low rise buildings: CFD with LES versus full scale and wind tunnel measurements

        Aly Mousaad ALY,Hamzeh Gol-Zaroudi 한국풍공학회 2020 Wind and Structures, An International Journal (WAS Vol.30 No.1

        This paper focuses on the processes of wind flow in atmospheric boundary layer, to produce realistic full scale pressures for design of low-rise buildings. CFD with LES turbulence closure is implemented on a scale 1:1 prototype building. A proximity study was executed computationally in CFD with LES that suggests new recommendations on the computational domain size, in front of a building model, apart from common RANS-based guidelines (e.g., COST and AIJ). Our findings suggest a location of the test building, different from existing guidelines, and the inflow boundary proximity influences pressure correlation and reproduction of peak loads. The CFD LES results are compared to corresponding pressures from open jet, full scale, wind tunnel, and the ASCE 7-10 standard for roof Component & Cladding design. The CFD LES shows its adequacy to produce peak pressures/loads on buildings, in agreement with field pressures, due to its capabilities of reproducing the spectral contents of the inflow at 1:1 scale.

      • KCI등재

        Control of wind-induced motion in high-rise buildings with hybrid TM/MR dampers

        Aly Mousaad Aly 한국풍공학회 2015 Wind and Structures, An International Journal (WAS Vol.21 No.5

        In recent years, high-rise buildings received a renewed interest as a means by which technical and economic advantages can be achieved, especially in areas of high population density. Taller and taller buildings are being built worldwide. These types of buildings present an asset and typically are built not to fail under wind loadings. The increase in a building\'s height results in increased flexibility, which can lead to significant vibrations, especially at top floors. Such oscillations can magnify the overall loads and can be annoying to the top floors\' occupants. This paper shows that increased stiffness in high-rise buildings may not be a feasible solution and may not be used for the design for comfort and serviceability. High-rise buildings are unique, and a vibration control system for a certain building may not be suitable for another. Even for the same building, its behavior in the two lateral directions can be different. For this reason, the current study addresses the application of hybrid tuned mass and magneto-rheological (TM/MR) dampers that can work for such types of buildings. The proposed control scheme shows its effectiveness in reducing floors\' accelerations for both comfort and serviceability concerns. Also, a dissipative analysis carried out shows that the MR dampers are working within the possible range of optimum performance. In addition, the design loads are dramatically reduced, creating more resilient and sustainable buildings. The purpose of this paper is to stimulate, shape, and communicate ideas for emerging control technologies that are essential for solving wind related problems in high-rise buildings, with the objective to build the more resilient and sustainable infrastructure and to optimally retrofit existing structures.

      • A case study of protecting bridges against overheight vehicles

        Aly Mousaad ALY,Marc A. Hoffmann 국제구조공학회 2022 Steel and Composite Structures, An International J Vol.43 No.2

        Most transportation departments have recognized and developed procedures to address the ever-increasing weights of trucks traveling on bridges in a service today. Transportation agencies also recognize the issues with overheight vehicles’ collisions with bridges, but few stakeholders have definitive countermeasures. Bridges are becoming more vulnerable to collisions from overheight vehicles. The exact response under lateral impact force is difficult to predict. In this paper, nonlinear impact analysis shows that the degree of deformation recorded through the modeling of the unprotected vehicle-girder model provides realistic results compared to the observation from the US-61 bridge overheight vehicle impact. The predicted displacements are 0.229 m, 0.161 m, and 0.271 m in the girder bottom flange (lateral), bottom flange (vertical), and web (lateral) deformations, respectively, due to a truck traveling at 112.65 km/h. With such large deformations, the integrity of an impacted bridge becomes jeopardized, which in most cases requires closing the bridge for safety reasons and a need for rehabilitation. We proposed different sacrificial cushion systems to dissipate the energy of an overheight vehicle impact. The goal was to design and tune a suitable energy absorbing system that can protect the bridge and possibly reduce stresses in the overheight vehicle, minimizing the consequences of an impact. A material representing a Sorbothane high impact rubber was chosen and modeled in ANSYS. Out of three sacrificial schemes, a sandwich system is the best in protecting both the bridge and the overheight vehicle. The mitigation system reduced the lateral deflection in the bottom flange by 89%. The system decreased the stresses in the bridge girder and the top portion of the vehicle by 82% and 25%, respectively. The results reveal the capability of the proposed sacrificial system as an effective mitigation system.

      • KCI등재

        Proposed approach for determination of tributary areas for scattered pressure taps

        Aly Mousaad ALY 한국풍공학회 2013 Wind and Structures, An International Journal (WAS Vol.16 No.6

        In wind load calculations based on pressure measurements, the concept of ‘tributary area’ is usually used. The literature has less guidance for a systematic computational methodology for calculating tributary areas, in general, and for scattered pressure taps, in particular. To the best of the author’s knowledge, there is no generic mathematical equation that helps calculate the tributary areas for irregular pressure taps. Traditionally, the drawing of tributary boundaries for scattered and intensively distributed taps may not be feasible (a time and resource consuming task). To alleviate this problem, this paper presents a proposed numerical approach for tributary area calculations on rectangular surfaces. The approach makes use of the available coordinates of the pressure taps and the dimensions of the surface. The proposed technique is illustrated by two application examples: first, quasi-regularly distributed pressure taps, and second, taps that have scattered distribution on a rectangular surface. The accuracy and the efficacy of the approach are assessed, and a comparison with a traditional method is presented.

      • KCI등재

        Wind profile management and blockage assessment for a new 12-fan Wall of Wind facility at FIU

        Aly Mousaad Aly,Arindam Gan Chowdhury,Girma Bitsuamlak 한국풍공학회 2011 Wind and Structures, An International Journal (WAS Vol.14 No.4

        Researchers at the International Hurricane Research Center (IHRC), Florida International University (FIU), are working in stages on the construction of a large state-of-the-art Wall of Wind (WoW) facility to support research in the area of Wind Engineering. In this paper, the challenges of simulating hurricane winds for the WoW are presented and investigated based on a scale model study. Three wind profiles were simulated using airfoils, and/or adjustable planks mechanism with and without grids. Evaluations of flow characteristics were performed in order to enhance the WoW’s flow simulation capabilities. Characteristics of the simulated wind fields are compared to the results obtained from a study using computational fluid dynamics (CFD) and also validated via pressure measurements on small-scale models of the Silsoe cube building. Optimal scale of the test model and its optimal distance from the WoW contraction exit are determined – which are two important aspects for testing using an open jet facility such as the WoW. The main objective of this study is to further the understanding of the WoW capabilities and the characteristics of its test section by means of intensive tests and validations at small scale in order to apply this knowledge to the design of the full-scale WoW and for future wind engineering testing.

      • KCI등재

        Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper

        Aly Mousaad Aly 국제구조공학회 2014 Smart Structures and Systems, An International Jou Vol.13 No.3

        Tuned mass dampers (TMDs) have been installed in many high-rise buildings, to improve their resiliency under dynamic loads. However, high-rise buildings may experience natural frequency changes under ambient temperature fluctuations, extreme wind loads and relative humidity variations. This makes the design of a TMD challenging and may lead to a detuned scenario, which can reduce significantly the performance. To alleviate this problem, the current paper presents a proposed approach for the design of a robust and efficient TMD. The approach accounts for the uncertain natural frequency, the optimization objective and the input excitation. The study shows that robust design parameters can be different from the optimal parameters. Nevertheless, predetermined optimal parameters are useful to attain design robustness. A case study of a high-rise building is executed. The TMD designed with the proposed approach showed its robustness and effectiveness in reducing the responses of high-rise buildings under multidirectional wind. The case study represents an engineered design that is instructive. The results show that shear buildings may be controlled with less effort than cantilever buildings. Structural control performance in high-rise buildings may depend on the shape of the building, hence the flow patterns, as well as the wind direction angle. To further increase the performance of the robust TMD in one lateral direction, active control using LQG and fuzzy logic controllers was carried out. The performance of the controllers is remarkable in enhancing the response reduction. In addition, the fuzzy logic controller may be more robust than the LQG controller.

      • KCI등재

        Wind loading on trees integrated with a building envelope

        Aly Mousaad ALY,Fabio Fossati,Tommaso Argentini,Girma Bitsuamlak,Alberto Franchi,Nicola Longarini,Pietro Crespi,Arindam Gan Chowdhury 한국풍공학회 2013 한국풍공학회지 Vol.17 No.1

        With the sustainability movement, vegetated building envelopes are gaining more popularity. This requires special wind effect investigations, both from sustainability and resiliency perspectives. The current paper focuses on wind load estimation on small- and full-scale trees used as part of green roofs and balconies. Small-scale wind load assessment was carried out using a wind tunnel testing in a global-effect study to understand the interference effects from surrounding structures. Full-scale trees were investigated at a large open-jet facility in a local-effect study to account for the wind-tree interaction. The effect of Reynolds number combined with shape change on the overall loads measured at the base of the trees (near the roots) has been investigated by testing at different model-scales and wind speeds. In addition, high-speed tests were conducted to examine the security of the trees in soil and to assess the effectiveness of a proposed structural mitigation system. Results of the current research show that at relatively high wind speeds the load coefficients tend to be reduced, limiting the wind loads on trees. No resonance or vortex shedding was visually observed.

      • The Use of Bracing Systems with MR Dampers in Super Tall Buildings

        Aly, Aly Mousaad Council on Tall Building and Urban Habitat Korea 2016 International journal of high-rise buildings Vol.5 No.1

        High-rise buildings are increasingly viewed as having both technical and economic advantages, especially in areas of high population density. Increasingly taller buildings are being built worldwide. Increased heights entail increasing flexibility, which can result in serviceability problems associated with significant displacements and accelerations at higher floors. The purpose of this paper is to present the concept of a versatile vibration control technology (MR dampers with bracings) that can be used in super tall buildings. The proposed technology is shown to be effective, from a serviceability point of view, as well as resulting in dramatically reduced design wind loads, thus creating more resilient and sustainable buildings.

      • SCIESCOPUS

        Control of wind-induced motion in high-rise buildings with hybrid TM/MR dampers

        Aly, Aly Mousaad Techno-Press 2015 Wind and Structures, An International Journal (WAS Vol.21 No.5

        In recent years, high-rise buildings received a renewed interest as a means by which technical and economic advantages can be achieved, especially in areas of high population density. Taller and taller buildings are being built worldwide. These types of buildings present an asset and typically are built not to fail under wind loadings. The increase in a building's height results in increased flexibility, which can lead to significant vibrations, especially at top floors. Such oscillations can magnify the overall loads and can be annoying to the top floors' occupants. This paper shows that increased stiffness in high-rise buildings may not be a feasible solution and may not be used for the design for comfort and serviceability. High-rise buildings are unique, and a vibration control system for a certain building may not be suitable for another. Even for the same building, its behavior in the two lateral directions can be different. For this reason, the current study addresses the application of hybrid tuned mass and magneto-rheological (TM/MR) dampers that can work for such types of buildings. The proposed control scheme shows its effectiveness in reducing floors' accelerations for both comfort and serviceability concerns. Also, a dissipative analysis carried out shows that the MR dampers are working within the possible range of optimum performance. In addition, the design loads are dramatically reduced, creating more resilient and sustainable buildings. The purpose of this paper is to stimulate, shape, and communicate ideas for emerging control technologies that are essential for solving wind related problems in high-rise buildings, with the objective to build the more resilient and sustainable infrastructure and to optimally retrofit existing structures.

      • SCIESCOPUS

        Wind loading on trees integrated with a building envelope

        Aly, Aly Mousaad,Fossati, Fabio,Muggiasca, Sara,Argentini, Tommaso,Bitsuamlak, Girma,Franchi, Alberto,Longarini, Nicola,Crespi, Pietro,Chowdhury, Arindam Gan Techno-Press 2013 Wind and Structures, An International Journal (WAS Vol.17 No.1

        With the sustainability movement, vegetated building envelopes are gaining more popularity. This requires special wind effect investigations, both from sustainability and resiliency perspectives. The current paper focuses on wind load estimation on small- and full-scale trees used as part of green roofs and balconies. Small-scale wind load assessment was carried out using a wind tunnel testing in a global-effect study to understand the interference effects from surrounding structures. Full-scale trees were investigated at a large open-jet facility in a local-effect study to account for the wind-tree interaction. The effect of Reynolds number combined with shape change on the overall loads measured at the base of the trees (near the roots) has been investigated by testing at different model-scales and wind speeds. In addition, high-speed tests were conducted to examine the security of the trees in soil and to assess the effectiveness of a proposed structural mitigation system. Results of the current research show that at relatively high wind speeds the load coefficients tend to be reduced, limiting the wind loads on trees. No resonance or vortex shedding was visually observed.