http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
S. Khodadadi,A. Ghanavati,M. R. Assari,M. Hatami,D. D. Ganji 대한기계학회 2015 JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY Vol.29 No.5
An experimental study is conducted on the heat transfer in the reservoir of a solar water-heater flat-plate solar collector to obtain itstemperature distribution. A total of 29 temperature sensors are placed inside the reservoir, and 2 sensors in the water inlet and outlet passages. The effect of the inlet and outlet positions on the temperature distribution inside the reservoir is studied to obtain the best locationfor the maximum temperature range. When the inlet position is II and the outlet position is B (Fig. 3(c)), the reservoir exhibits the bestperformance because of the high temperature range and areas inside it.