http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
무인감시시스템 구현을 위한 이동체 인식 알고리즘에 관한 연구
장국렬,방만원,박진홍,박순영 木浦大學校 情報産業硏究所 1996 情報産業硏究誌 Vol.4 No.-
In this paper, an effective algorithm which can detect moving objects from the image sequences and classify an intruder from other moving objects is presented for an implementation of unmanned surveillance system. The proposed algorithm uses a stick figure model for features of the moving object since the stick figure model can be represent the characteristics of the moving objects. The stick figure model is extracted by applying the thining algorithm to the binary difference image between the reference and the image of a moving object. The computer simulation is carried out to analyze the performance of the proposed algorithm. The results show that the algorithm can discriminate a moving person and a moving animal with high degree of reliability.
김진규,김상복,김국찬,천기정,김인규,박효국,이강석 대한방사선 방어학회 1993 방사선방어학회지 Vol.18 No.2
생물학적 선량평가를 위한 생화학적 지표 연구로서 흰쥐 혈액내 효소활성도의 변화를 조사한 결과는 다음과 같다. 1) Alkaline phosphatase 활성도는 0.1, 0.25, 0.5, 2, 4 Gy의 방사선 조사후 24시간까지 혈액내 활성도가 증가하였고 72시간 경과시에는 대조군과 비슷한 활성도를 보였다. Creatine kinase는 2, 4 Gy 방사선 조사후 혈액내에서 활성도에서 활성도가 72시간까지 증가하였으나 0.1, 0.25Gy, 0.5 Gy 방사선 조사시에는 커다란 변화를 보이지 않았다. 2) Malate dehydrogenase 활성도는 0.1, 0.25, 0.5 Gy 방사선 조사시에는 커다란 변화가 없었으며 lactate dehydrogenase는 방사선 조사후 활성도가 감소하였다. 3) GOT의 활성도는 선량률 0.1Gy/min.로 0.1, 0.25, 0.5, 2, 4 Gy 조사후에는 어떠한 변화도 없었으며 선량률 0.5 Gy/sec.로 0.5, 1, 1.5, 2, 3, 5, 7 Gy로 조사후에는 증가현상을 보이고 있다. Acid phosphatase 활성도는 상기의 어떠한 선량에서도 나타나지 않고 있다. 잠재적으로 이러한 효소들은 방사선 피폭의 지표물질로 사용될 수 있으며 생화학적 지식과 기술을 이용한 좀더 나은 지표물질을 찾기 위하여 계속적인 조사가 필요하다. Enzyme activity changes in rat blood as biochemical indicator useful for evaluating exposure dose were experimentally studied. The experimental results obtained are as follows: 1) Alkaline phosphatase activities increased in the blood serum until 24 hours after 0.1, 0.25, 0.5, 2 and 4 Gy irradiation and its activities returned mormal condition after 72 hours of post-irradiation. Creatine kinase activities increased in the blood serum until 72 hours after 2 and 4 Gy irradiation but any significant activity changes were not detected after 0.1, 0.25 Gy irradiation. 2) Malate dehydrogenase activities did not reveal available changes changes after 0.1, 0.25, 0.5 Gy irradiation and lactate dehydrogenase activities decreased in the blood serum after 0.1, 0.25, 0.5 Gy irradiation. 3) Glutamate oxaloacetate transaminase activity changes were detected in the blood serum after 0.1, 0.25, 0.5, 2, 4 Gy(0.1 Gy/min.) and GOT activities increased after 0.5, 1, 1.5, 2, 3, 5, 7 Gy(0.5 Gy/sec.). Any acid phosphatase activities were detected in the blood serum after 0.1, 0.25, 0.5, 2, 4 Gy(0.1 Gy/min.) and 0.5, 1, 1.5, 2, 3, 5, 7 Gy(0.5 Gy/sec.) irradiation. Potentially some of these enzymes can be used as indicator protein for radiation injury. Futher investigation is needed to find better biochemical indicatiors utilizing recent knowledge and techniques of biochemistry.
김국찬,이강석,김진규,김인규,박효국,천기정,김상복 대한방사선 방어학회 1993 방사선방어학회지 Vol.18 No.2
우라늄 피폭후 효소활성도가 내부피폭의 biomarker로서의 가능성을 연구하기 위하여 수서생물인 잉어9Caprinus carpio)의 복강내 우라늄 투여시 간조직에서 일어나는 여러가지 효소계의 변화를 조사하였다. 이러한 효소활성도의 변화는 우라늄 내부피폭의 biomarker로서 가능성을 가지고 있으며 연구결과는 다음과 같다. 1) 6일째까지 우라늄을 주사하여 적출한 간에서의 전체단백질량은 계속 감소하고 있다. 2) 세포내의 lysosome내에 함유하고 있는 acid protease와 β-glucuronidase의 활성도는 6일째 투여후까지 활성도가 감소하고 있다. 3) Alkaline phosphatase의 경우 6일째 우라늄 투여후까지 증가하고 있으며 반대로 acid phosphatase의 경우 6일째 우라늄 투여후까지 활성도가 급격히 증가하였고 glutamate oxaloacetate transaminase의 활성도는 완만하게 증가하고 있다. 4) Creatine kinase의 활성도는 완만한 감소를 보이고 있으며 malate dehydrogenase는 첫번 우라늄 투여후에 활성도가 급격히 감소하였고 3일째 우라늄 투여후에는 활성도가 거의 나타나지 않았다. We examined various enzyme activity changes by intraperitioneal injection uranium in the carp liver. These enzyme activity changes can be used as biochemical indicators of internal exposure to uranium. The results were followings ; 1) Total protein concentration decreased by intraperitoneal injection in the carp liver. 2) Lysosomal acid protease and β-glucronidase activities increased in the liver until sixth intraperitoneal injection of uranium, but lysosomal acid phosphatase activities decreased in the liver until the sixth injection of uranium. 3) Alkaline phosphatase activities sharply increased and Glutamate oxaloacetate Transaminase activities steadily decreased in the liver until the sixth injection of uranium. 4) Creatine %kinase activities steadily decreased and malate dehydrogenase activities sharply decreased in the liver after the primary injection of uranium. Any malate dehydrogenase activities was not detected after sixth injection of uranium.
자기동조와 칼만 필터를 이용한 동적위치제어 시스템에 관한 연구
金元圭,朴鍾國,오진용 慶熙大學校 1987 論文集 Vol.16 No.-
The position-control systems for dynamically positioned vessels include wave filters remove the wave motion signal. The implementation of linear filtering theory incurs computational difficulties specially in applications to large dimensional systems. These difficulties can be overcome by using a partitioning technique. The approach was developed for application to the dynamic ship positioning control problem and has the advantage that existing nonadaptive Kalman filtering system may be easily modified to include the self-tuning feature.
구내 표준 방사선사진을 이용한 구내방사선촬영기의 선질 평가
이상섭,권혁락,심우현,오승현,이지연,전국진,김기덕,박창서 대한구강악안면방사선학회 2000 Imaging Science in Dentistry Vol.30 No.3
Purpose : This study was to evaluate the beam quality of intraoral X-ray equipments used at Yonsei University Dental Hospital (YUDH) using the half value layer (HVL) and the characteristic curve of intraoral standard X-ray film. Materials and Methods : The study was done using the intraoral X-ray equipments used at each clinical department at YUDH. Aluminum filter was used to determine the HVL. Intraoral standard film was used to get the characteristic curve of each intraoral X-ray equipment. Results : Most of the HVLs of intraoral X-ray equipments were higher than the least recommended thickness, but the REX 601 model used at the operative dentistry department and the X-707 model used at the pediatric dentistry department had HVLs lower than the recommended thickness. The slopes of the characteristic curves of films taken using the PANPAS 601 model and REX 601 model at operative dentistry department, the X-705 model of prosthodontic dentistry department, and the REX601 model at the student clinic were relatively low. Conclusion : HVL and the characteristic curve of X-ray film can be used to evaluate the beam quality of intraoral X-ray equipment. In order to get the best X-ray films with the least radiation exposure to patients and best diagnostic information in clinical dentistry, X-ray equipment should be managed in the planned and organized fashion. (Korean J Oral Maxillofac Radiol 2000; 30: 183-188)
Differential Expression Patterns of Gangliosides in Human and Mini-pig Kidney cells
Jin-Hyoung Cho,Ji-Su Kim,Jae-Sung Ryu,Jung-Woo Jin,Hyo-Jung Yang,Eun-Jung Jeong,So-Dam Lee,So-Hyun Lee,Young-Choon Lee,Young-kug Choo 한국당과학회 2009 한국당과학회 학술대회 Vol.2009 No.1
Ganglioside are ubiquitous membrane component in mammalian cells and suggested to play important roles in various cell functions such as cell-cell recognition, differentiation and transmembrane signaling. These compounds are localized in a glycosphingolipid-enriched microdomain on the cell surface and regulated by the glycosphingolipid composition. However, the role that gangliosides play in immune rejection response by xenotransplantation is not yet clearly understood. In this study, we differential expression patterens of gangliosides between HEK293 cells (human embryonic kidney cells) and mini-pig kidney cells (NIH-mini pig, primary cultured) was investigated. we examined expression level of high-performance thin-layer chromatography (HPTLC) showed that HEK293 cells and mini-pig kidney cells contained GM3, GM2 and GD3 as major gangliosides. Moreover, ganglioside GM3, GM2, GM1 and GD3 which are gangliosides of mini-pig kidney cells expressed more than HEK293 cells. Especially, ganglioside GT1b expressed in HEK293 cells, not in mini-pig kidney cells. and GM1 expressed in mini-pig kidney cells, not in HEK293 cells. As a results suggest that differential expression patterens of gangliosides of HEK293, mini-pig kidney cells are related immune rejection response in xenotransplantation by biomaker.