Assessment on the Potential Role of Applying Cryoprobe for Tissue Ablation
서민호,진윤태,Sang Jung Park,Sun Young Kim,Hye Jin Cho,최혁순,Hoon Jai Chun,Chang Duck Kim,HoSangRyu,Yang Seok Chae 대한소화기내시경학회 2012 Clinical Endoscopy Vol.45 No.1
Background/Aims: Cryotherapy is the therapeutic application for tissue ablation. Clinical applications of cryotherpy such as in pulmonology have increased. Until now, its development in gastroenterology has been insignificant. But, as clinical application such as mucosal ablation on Barrett’s esophagus became possible, various applications have been developed. Therefore, it is important to make standards of tissue injury’s extent in cryotherapy prior to clinical trial. We evaluated the tissue injury according to the application of cryoprobe with a pig model. Methods: Cryoprobe was applied to several different segments of the esophagus and stomach for various lengths of time using various number of probe’s contact in a pig model. After 48 hours, esophagus and stomach were harvested and histological tissue injury was assessed. The extent of tissue injury was decided by the injury of the deepest layer. Results: Endoscopic application of cryoprobe on esophagus and stomach resulted in a dose-dependent injury: esophageal necrosis was limited to the submucosa after 10 seconds of cryotherapy, and extended to involve the transmural necrosis after over 15 seconds. Necrosis on stomach was extended to involve the transmural necrosis after over 20 seconds. Conclusions: Positive relationship was seen between the duration and frequency of cryoprobe application and the extent of tissue injury.
Sun Young Kim,이홍식,현종진,Min Ho Seo,Sun Young Yim,Ha Young Oh,Hye Sook Kim,금보라,Yeon Seok Seo,YongSikKim,Yoon Tae Jeen,Hoon Jai Chun,엄순호,Chang Duck Kim,HoSangRyu 대한소화기내시경학회 2011 Clinical Endoscopy Vol.44 No.2
Background/Aims: Since endoscopes are reusable apparatus classified as semicritical item, thorough reprocessing to achieve high-level disinfection is of utmost importance to prevent spread of infection. To improve disinfection efficacy and safety, disinfectants and endoscope reprocessors are continuously evolving. This study aimed to compare the efficacy of the combination of polyhexamethylenebiguanide hydrochloride-alkyldimethylbenzylammonium chloride (PHMB-DBAC) and orthophthalaldehyde (OPA) used respectively in ultrasonographic cleaning incorporated automated endoscope reprocessors: COOLENDO (APEX Korea) or OER-A (Olympus Optical). Methods: A total of 86 flexible upper endoscopes were randomly reprocessed with either COOLENDO/PHMB-DBAC or OER-A/OPA. Culture samplings were done at two sites (endoscope tip and working channel) which were later incubated on blood agar plate. Bacterial colonies were counted and identified. Results: The culture-positive rate at the endoscope tip and working channel was 0% and 2.33% for COOLENDO/PHMB-DBAC and 4.65% and 0% for OER-A/OPA. Staphylococcus hominis was cultured from one endoscope reprocessed with COOLENDO/PHMB-DBAC and Pseudomonas putida was isolated from two endoscopes reprocessed with OER-A/OPA. Conclusions: The reprocessing efficacy of COOLENDO/PHMB-DBAC was non-inferior to that of OER-A/OPA (p=0.032; confidence interval, -0.042 to 0.042). During the study period, significant side effect of PHMB-DBAC was not observed.