RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Respiratory Responses during Exercise in Self-contained Breathing Apparatus among Firefighters and Nonfirefighters

        David Hostler,David R. Pendergast 한국산업안전보건공단 산업안전보건연구원 2018 Safety and health at work Vol.9 No.4

        Background: Firefighters are required to use self-contained breathing apparatus (SCBA), which impairs ventilatory mechanics. We hypothesized that firefighters have elevated arterial CO2 when using SCBA. Methods: Firefighters and controls performed a maximal exercise test on a cycle ergometer and two graded exercise tests (GXTs) at 25%, 50%, and 70% of their maximal aerobic power, once with a SCBA facemask and once with protective clothing and full SCBA. Results: Respiratory rate increased more in controls than firefighters. Heart rate increased as a function of oxygen consumption (V : O2 ) more in controls than firefighters. End-tidal CO2 (ETCO2) during the GXTs was not affected by work rate in either group for either condition but was higher in firefighters at all work rates in both GXTs. SCBA increased ETCO2 in controls but not firefighters. Conclusions: The present study showed that when compared to controls, firefighters’ hypoventilate during a maximal test and GXT. The hypoventilation resulted in increased ETCO2, and presumably increased arterial CO2, during exertion. It is proposed that firefighters have altered CO2 sensitivity due to voluntary hypoventilation during training and work. Confirmation of low CO2 sensitivity and the consequence of this on performance and long-term health remain to be determined.

      • SCOPUSKCI등재

        Respiratory Responses during Exercise in Self-contained Breathing Apparatus among Firefighters and Nonfirefighters

        Hostler, David,Pendergast, David R. Occupational Safety and Health Research Institute 2018 Safety and health at work Vol.9 No.4

        Background: Firefighters are required to use self-contained breathing apparatus (SCBA), which impairs ventilatory mechanics. We hypothesized that firefighters have elevated arterial $CO_2$ when using SCBA. Methods: Firefighters and controls performed a maximal exercise test on a cycle ergometer and two graded exercise tests (GXTs) at 25%, 50%, and 70% of their maximal aerobic power, once with a SCBA facemask and once with protective clothing and full SCBA. Results: Respiratory rate increased more in controls than firefighters. Heart rate increased as a function of oxygen consumption ($V_{O_2}$) more in controls than firefighters. End-tidal $CO_2$ ($ETCO_2$) during the GXTs was not affected by work rate in either group for either condition but was higher in firefighters at all work rates in both GXTs. SCBA increased $ETCO_2$ in controls but not firefighters. Conclusions: The present study showed that when compared to controls, firefighters' hypoventilate during a maximal test and GXT. The hypoventilation resulted in increased $ETCO_2$, and presumably increased arterial $CO_2$, during exertion. It is proposed that firefighters have altered $CO_2$ sensitivity due to voluntary hypoventilation during training and work. Confirmation of low $CO_2$ sensitivity and the consequence of this on performance and long-term health remain to be determined.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼