http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Tran Ha Thi Thanh,Dang Anh Kieu,Ly Duc Viet,Vu Hao Thi,Hoang Tuan Van,Nguyen Chinh Thi,Chu Nhu Thi,Nguyen Vinh The,Nguyen Huyen Thi,Truong Anh Duc,Pham Ngoc Thi,Dang Hoang Vu 아세아·태평양축산학회 2020 Animal Bioscience Vol.33 No.10
Objective: The rapid and reliable detection of the African swine fever virus (ASFV) plays an important role in emergency control and preventive measures of ASF. Some methods have been recommended by FAO/OIE to detect ASFV in clinical samples, including real-time polymerase chain reaction (PCR). However, mismatches in primer and probe binding regions may cause a false-negative result. Here, a slight modification in probe sequence has been conducted to improve the qualification of real-time PCR based on World Organization for Animal Health (OIE) protocol for accurate detection of ASFV in field samples in Vietnam. Methods: Seven positive confirmed samples (four samples have no mismatch, and three samples contained one mutation in probe binding sites) were used to establish novel real-time PCR with slightly modified probe (Y = C or T) in comparison with original probe recommended by OIE. Results: Both real-time PCRs using the OIE-recommended probe and novel modified probe can detect ASFV in clinical samples without mismatch in probe binding site. A high correlation of cycle quantification (Cq) values was observed in which Cq values obtained from both probes arranged from 22 to 25, suggesting that modified probe sequence does not impede the qualification of real-time PCR to detect ASFV in clinical samples. However, the samples with one mutation in probe binding sites were ASFV negative with OIE recommended probe but positive with our modified probe (Cq value ranked between 33.12-35.78). Conclusion: We demonstrated for the first time that a mismatch in probe binding regions caused a false negative result by OIE recommended real-time PCR, and a slightly modified probe is required to enhance the sensitivity and obtain an ASF accurate diagnosis in field samples in Vietnam.
Relaxor Behaviors in xBaTiO₃–(1-x)CoFe₂O₄ Materials
Cao Thi My Dung,Nhu Hoa Tran Thi,Kieu Hanh Thi Ta,Vinh Cao Tran,Bao Thu Le Nguyen,Van Hieu Le,Phuong Anh Do,Anh Tuan Dang,Heongkyu Ju,Bach Thang Phan 한국자기학회 2015 Journal of Magnetics Vol.20 No.4
Dielectric properties of xBaTiO₃–(1-x)CoFe₂O₄ composite materials have been investigated. Dielectric properties of BaTiO₃, CoFe₂O₄ and 0.5BaTiO₃–0.5CoFe₂O₄ samples show frequency dependence, which is classified as relaxor behavior with different relaxing degree. The relaxor behaviors were described using the modified Curier-Weiss and Vogel–Fulcher laws. Among three above samples, the BaTiO₃ sample has highest relaxing degree. Photoluminescence spectral indicated defects, which might in turn control relaxing degree.