http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Modular DC Solid State Transformer with Fault-Tolerant Function
Xiangqi Meng,Yanbing Jia,Chunguang Ren,Xiaoqiang Lin,Baifu Zhang 전력전자학회 2019 ICPE(ISPE)논문집 Vol.2019 No.5
A modularized control method with faulttolerant function is proposed under the condition that a module of DC solid state transformer (DCSST) fails due to input short circuit. The decoupling control strategy is deduced by establishing the mathematic model of the DCSST. The maximum input voltage is selected as the reference voltage by adding diodes at the input side. The proposed system can automatically adjust the input voltage reference to keep the output voltage stability for the module in DCSST with short-circuit fault. Simulation and experiment results show that the proposed control method can decouple the output voltage and the input average voltage, maintain the output voltage stable and improve the reliability of the system when a short circuit occurs in a module of DCSST.
Simulation of the damping effect of a high-rise CRST frame structure
Xilin Lu,Chunguang Meng,Hongmei Zhang 사단법인 한국계산역학회 2012 Computers and Concrete, An International Journal Vol.9 No.4
The damping effect of a Concrete-filled Rectangular Steel Tube (CRST) frame structure is studied in this paper. Viscous dampers are employed to insure the function of the building especially subjected to earthquakes, for some of the main vertical elements of the building are not continuous. The shaking table test of a 1:15 scale model was conducted under different earthquake excitations to recognize the seismic behavior of this building. And the vibration damping effect was also investigated by the shaking table test and the simulation analysis. The nonlinear time-history analysis of the shaking table test model was carried out by the finite element analysis program CANNY. The simulation model was constructed in accordance with the tested one and was analyzed under the same loading condition and the simulation effect was then validated by the tested results. Further more, the simulation analysis of the prototype structure was carried out by the same procedure. Both the simulated and tested results indicate that there are no obvious weak stories on the damping equipped structure, and the dampers can provide the probability of an irregular CRST frame structure to meet the requirements of the design code on energy dissipation and deformation limitation.
Wang, Lei,Han, Xiaoqing,Meng, Runquan,Ren, Chunguang,Wang, Qi,Zhang, Baifu The Korean Institute of Power Electronics 2018 JOURNAL OF POWER ELECTRONICS Vol.18 No.5
This paper proposes a modified control strategy to improve the performance of three-phase four-leg shunt active power filters (APFs) for the compensation of three phase unbalanced loads. Unbalanced current cannot be obtained accurately by a harmonic detector due to the lower frequency. The proposed control strategy eliminates conventional harmonic detectors by directly regulating the source current. Therefore, the computational complexity is greatly reduced and the performance of the APF is improved. A mathematic model has been developed based on the source currents. The corresponding controllers have been designed based on the sinusoidal internal model principle. The proposed control strategy can guarantee excellent compensation performance and stable operation after an extreme disturbance such as a short circuit fault. In addition, the proposed technique can selectively compensate specific harmonics. A 50kVA prototype APF is implemented in the laboratory to validate the feasibility and performance of the proposed control strategy.
Zhang, Baifu,Han, Xiaoqing,Meng, Runquan,Ren, Chunguang,Wang, Lei,Song, Tianhao,Liu, Yizhao The Korean Institute of Power Electronics 2021 JOURNAL OF POWER ELECTRONICS Vol.21 No.1
The redundant design of multi-paralleled bidirectional power converters (BPCs) provides technical support for hybrid microgrid systems to consume more distributed generations (DGs) and DC loads. However, the multi-BPCs also provide paths for circulating current. In addition, the AC sub-grid may operate under unbalanced conditions due to the consumption of single-phase loads and power electronic devices. In addition, unbalanced three-phase voltage deteriorates the generation of circulating current. In this paper, an adaptive virtual impedance control method based on second-order generalized integration (SOGI) is proposed to suppress circulating current on the basic analysis of circulating current generation mechanism, the equivalent model establishment, and the suppression principle. The virtual impedance is dynamically adjusted in real-time based on the power oscillation caused by unbalanced voltage. Moreover, an integral term is added to the reactive power droop control to realize the tracking of voltage without static error. Finally, the effectiveness and feasibility of the proposed control algorithm are verified by experiments. The research results show that the proposed control method can optimize the damping characteristics, reduce the voltage difference between the BPCs, and improve the current sharing effect.
Solidification of uranium mill tailings by MBS-MICP and environmental implications
Niu Qianjin,Li Chunguang,Liu Zhenzhong,Li Yongmei,Meng Shuo,He Xinqi,Liu Xinfeng,Wang Wenji,He Meijiao,Yang Xiaolei,Liu Qi,Liu Longcheng 한국원자력학회 2022 Nuclear Engineering and Technology Vol.54 No.10
Uranium mill tailing ponds (UMTPs) are risk source of debris flow and a critical source of environmental U and Rn pollution. The technology of microbial induced calcium carbonate precipitation (MICP) has been extensively studied on reinforcement of UMTs, while little attention has been paid to the effects of MICP on U & Rn release, especially when incorporation of metakaolin and bacillus subtilis (MBS). In this study, the reinforcement and U & Rn immobilization role of MBS -MICP solidification in different grouting cycle for uranium mill tailings (UMTs) was comprehensively investigated. The results showed that under the action of about 166.7 g/L metakaolin and ~50% bacillus subtilis, the solidification cycle of MICP was shortened by 50%, the solidified bodies became brittle, and the axial stress increased by up to 7.9%, and U immobilization rates and Rn exhalation rates decrease by 12.6% and 0.8%, respectively. Therefore, the incorporation of MBS can enhance the triaxial compressive strength and improve the immobilization capacity of U and Rn of the UMTs bodies solidified during MICP, due to the reduction of pore volume and surface area, the formation of more crystals general gypsum and gismondine, as well as the enhancing of coprecipitation and encapsulation capacity
Lei Wang,Xiaoqing Han,Runquan Meng,Chunguang Ren,Qi Wang,Baifu Zhang 전력전자학회 2018 JOURNAL OF POWER ELECTRONICS Vol.18 No.5
This paper proposes a modified control strategy to improve the performance of three-phase four-leg shunt active power filters (APFs) for the compensation of three phase unbalanced loads. Unbalanced current cannot be obtained accurately by a harmonic detector due to the lower frequency. The proposed control strategy eliminates conventional harmonic detectors by directly regulating the source current. Therefore, the computational complexity is greatly reduced and the performance of the APF is improved. A mathematic model has been developed based on the source currents. The corresponding controllers have been designed based on the sinusoidal internal model principle. The proposed control strategy can guarantee excellent compensation performance and stable operation after an extreme disturbance such as a short circuit fault. In addition, the proposed technique can selectively compensate specific harmonics. A 50kVA prototype APF is implemented in the laboratory to validate the feasibility and performance of the proposed control strategy.