Jin‑Kyung Jeon,Hyunseon Seo,Jimin Park,Soo Ji Son,Yeong Rim Kim,Eun Shil Kim,Jong Woong Park,Woong‑Gyo Jung,Hojeong Jeon,Yu‑Chan Kim,Hyun‑Kwang Seok,Jae Ho Shin,Myoung‑Ryul Ok 대한금속·재료학회 2019 METALS AND MATERIALS International Vol.25 No.4
The excessive initial corrosion rate of Mg is a critical limitation in the clinical application of biodegradable Mg implantsbecause the device loses its fi xation strength before the fractured bone heals. This study suggests a new approach to overcomethis hurdle by accelerating tissue regeneration instead of delaying the implant biodegradation. As angiogenesis is anessential process in early bone regeneration, a Mg implant coated with electrospun nanofi bers containing nitric oxide (NO),which physiologically promotes angiogenesis, is designed. The integrated device enables adjustable amounts of NO to bestored on the NO donor-conjugated nanofi ber coating, stably delivered, and released to the fractured bone tissue near theimplanted sites. An in vitro corrosion test reveals no adverse eff ect of the released NO on the corrosion behavior of the Mgimplant. Simultaneously, the optimal concentration level of NO released from the implant signifi cantly enhances tube networkformation of human umbilical vein endothelial cells without any cytotoxicity problem. This indicates that angiogenesis canbe accelerated by combining NO-releasing nanofi bers with a Mg implant. With its proven feasibility, the proposed approachcould be a novel solution for the initial stability problem of biodegradable Mg implants, leading to successful bone fi xation.
폴리에스테르 섬유 감량시스템용 프로세서 타이트레이터 개발
조진호,이흥락,이종현,김명남,구성모,김무영,진경찬,유병희,강민수,김국진 경북대학교 센서기술연구소 1993 연차보고서 Vol.1993 No.-
폴리에스테르 섬유 감량시스템의 제어를 위해서는 처리조 내에서 감량되는 섬유가 목표 감량치에 도달했는지를 판단해 주는 장치가 필요하다. 본 연구에서는 가성소다용액의 초농도 및 섬유 감량 정도의 정확한 측정과 감량 종료시간의 산출 및 이에 따른 종료신호를 발생할 수 있는 폴리에스테르 섬유 감량기 전용의 자동적정장치를 개발하였다. To control caustic soda treatment system for the polyester fabric reduction, we need the device to determine that the fabric has been arrived target reduction value. In this study, we develope an automatic process titrator for the caustic soda treatment system. Major functions of the target titrating system are accurate measurements of the caustic soda concentration and then producing the end point signal for caustic soda treatment system.
근관확대 및 세척 주사바늘의 근관 내 위치가 치근단 3 mm 부위의 근관 세정에 미치는 영향
문호진,홍찬의 大韓齒科保存學會 2012 Restorative Dentistry & Endodontics Vol.37 No.1
Objectives: The aim of this study was to test the hypothesis, that the effectiveness of irrigation in removing smear layer in the apical third of root canal system is dependent on the depth of placement of the irrigation needle into the root canal and the enlargement size of the canal. Materials and Methods: Eighty sound human lower incisors were divided into eight groups according to the enlargement size (#25, #30, #35 and #40) and the needle penetration depth (3 mm from working length, WL-3 mm and 9 mm from working length, WL-9 mm). Each canal was enlarged to working length with Profile.06 Rotary Ni-Ti files and irrigated with 5.25% NaOCl. Then, each canal received a final irrigation with 3 mL of 3% EDTA for 4 min, followed by 5 mL of 5.25% NaOCl at different level (WL-3 mm and WL-9 mm) from working length. Each specimen was prepared for the scanning electron microscope (SEM). Photographs of the 3mm area from the apical constriction of each canal with a magnification of ×250, ×500, ×1,000, ×2,500 were taken for the final evaluation. Results: Removal of smear layer in WL-3 mm group showed a significantly different effect when the canal was enlarged to larger than #30. There was a significant difference in removing apical smear layer between the needle penetration depth of WL-3 mm and WL-9 mm. Conclusions: Removal of smear layer from the apical portion of root canals was effectively accomplished with apical instrumentation to #35/40 06 taper file and 3 mm needle penetration from the working length.
진찬용,허철부 明知大學校 經濟硏究所 1989 경영연구 Vol.5 No.1
The purpose of this paper is to study the imprecision in linear programming problem. The imprecision in linear programming problem is classified into tow types. Type one is to deal with the imprecision of objective function coefficients and type two is to deal with the imprecision of RHS. A solution procedure is proposed for this two types using the fuzzy approach which has become accepted as a tool for dealing with a certain form of imprecision inherent to multiobjective decision making environment.
SVD 알고리즘 및 HMM을 이용한 얼굴 및 눈 패턴 검출
진경찬,김명남,신장규,손병기,조진호 경북대학교 센서기술연구소 1998 센서技術學術大會論文集 Vol.9 No.1
The studies about automatic pattern detection of the eye and face from the human image acquired by the CCD image sensor have good applicabilities in the industry, home automation, and data communication field. In general, pattern detection method consists of feature based matching and template matching. In feature based matching, the feature vector is extracted with DLM(dynamic linking matching), EBGM(elastic bunch graph matching), HMM(hidden markov model) matching and knowledge based matching using statistical characteristics. In template matching, in general, the template vector is extracted with PCA(principal component analysis). When these method applied in the face and eye detection, each method has its own merits and some disadvantage. Therefore, by combined utilization of SVD(singular value decomposition) and HMM algorithm, is expected that we can selectively make use of each methods advantage and it result in improved detection accuracy. In this paper, we proposed the method for face and eye detection, which was combined by the two algorithms, to be suitable for the high speed image processing using DSP chip or microprocessor. In the beginning, template matching was followed by a template extraction using batch SVD algorithm and then face pattern was classified and recognized by HMM algorithm which is one of feature based matching technique. Finally, eye pattern detection was performed by pattern search neural network utilizing eigeneye image.
Thermocouple을 이용한 Buchanan Plugger 표면의 온도상승 분석
조진숙,황윤찬,김선호,황인남,최보영,정영진,정우남,오원만 전남대학교 치의학연구소 2003 구강과학 Vol.15 No.4
This study was performed to confirm the actual temperature rise on the surface of Buchanan plugger by evaluating the temperature rise on the surface of it, the peak temperature of pluggers of various size using thermocouple. The heat carrier system 'System B Heatsource' (Model 1005, Analytic Technologies, USA) and the Buchanan pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200 which Dr. Buchanan's "Continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. The touch mode was used. Five thermocouples were placed in direct contact with the surface of each size of Buchanan's pluggers at 1 ㎜ increments from the tip to the 4 ㎜ length of shank. Each thermocouple was secured with cyanoacrylate adhesive and orthodontic resin block. The two wire leads of each thermocouple were connected to the appropriate channels of Data Logger. This was configured to simultaneously record input from the five thermocouples. The heat control spring was touched for 1, 2, 3, 4 and 5 seconds, and the temperature rise on the surface of the pluggers were measured at 1 sec intervals for more than 5 seconds with an accuracy of 0.01. Ten trials was determined for each plugger. The average of temperature rise and standard deviation was calculated for each size of plugger. The data were statistically analyzed by one-way ANOVA to determine their significance. The results as follows. 1. The position at which the temperature peaked was approximately at 1∼2㎜ far from the tip of Buchanan plugger (p<0.01). 2. The peak temperature was 215.25±2.28℃ in F plugger, 185.94±2.19℃ in FM plugger, 169.51±9.12℃ in M plugger, and 160.79±1.27℃ in ML plugger and the peak temperature was highest in F type and followed by, in descending order, FM type, M type. ML type showed the lowest peak temperature (p<0.01). This results suggest that the actual temperature on the surface of the pluggers does not correlate well with the temperature set on digital display. Heat concentrates around the tip. The larger plugger reveals lower temperature rise relatively.