http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
조선 후기 영건의궤에 실린 안초공의 기능과 표기법 연구
이우종,Lee, Woo-Jong 한국건축역사학회 2018 건축역사연구 Vol.27 No.4
This study is focusing on anchogongs(按草工) in yeonggeonuigwes(營建儀軌), which were recorded with few details and in unsettled transcriptions. First, the positions and functions of anchogongs in $18^{th}$ censtury are analyzed by comparing to anchogongs in more detailed early $19^{th}$ century yeonggeonuigwes and those in extant buildings. Second, with the result, the historical significances are presumed in changing transcriptions of anchogong terms in those uigwes. In $18^{th}$ century uigwes, most of anchogongs are functioned as matbo-anchogongs and only four anchogongs in a gate building were used as jongryang-anchogongs. It is mainly because the sorts of buildings in $18^{th}$ century yeonggeonuigwes had only several varieties: most of the buildings belonging royal shrines. Transcriptions of anchogong terms had been changed for reflecting functional developments of anchogongs in $18^{th}$ century. However, reflections were much later than changes of actual functions.
신생(新生) 송아지에 있어서 Theileria sergenti의 감염(感染)에 관한 연구(硏究)
이우종 ( Woo Jong Lee ),이성식 ( Sung Sik Lee ),이재구 ( Jae Gu Lee ),백병걸 ( Byung Girl Baek ) 한국가축위생학회 1994 韓國家畜衛生學會誌 Vol.17 No.1
The rate of 58 neonatal calves in infection of Theileria sergenti was investigated in random samples on the farms located in Kyunggi, Chonbuk districts of Korea. 1. The criteria used in veryfying infection with T. sergenti included the detection of parasites by giemsa stain and acridine orange stain in the blood smear slides. 2. Further evidence of current or previous exposure to T. sergenti was based on demonstration of T. sergenti specific antibody and antigen by the western immunoblot and the directed immunofluorescent antibody test in the peripherial blood of the calves. 3. The prevalence rates were 35%, 50% in Kyunggi, Chonbuk provinces respectively and the overall prevalence in all the farms was 43.2% by means of acridine orange stain. 4. The parasites that were observed in the peripherial blood of calves was showen surely by the western immunoblot to the characteristic 34KD antigen among the proteins of T. sergenti (Korean isolate). 5. And the antigen of the neonatal calves reacted at the very highest titer(1:2, 560) 6. These data highlight the significances of T. sergenti in the neonatal calf disease in Korea.
이우종(Lee Woo-Jong) 대한건축학회 2010 대한건축학회논문집 Vol.26 No.7
The purpose of this study is to survey the wooden parts and structures of double-layered eaves in traditional Korean timber buildings, and to compare them with similar parts and structures refered in official architectural documents of Chinese dynasties, such as Yingzaofashi(營造法式) from Northern Song dynasty and Gongchengzuofazeli(工程做法則例) from Qing dynasty. Double layered eaves are a kind of architectural design constituents for high-grade buildings. They are eaves that have additional superimposed eaves at the tip of normal single-layered eaves. Double-layered eaves are composed of many parts like eaves rafters(cheomaseokkarae 처마서까래), additioanl rafters(buyeon 부연), eaves connectors(pyeonggodae 평고대), rafter-gap-blockers(buyeonchakko 부연착고), tile supporters(yeonham 연함), etc. There are some variation of their framing, and they can be clues for comparative studies on East Asian architecture.
불평형 및 비선형부하 시 전력품질 향상을 위한 독립형 인버터의 전압제어 기법
이우종(Wujong Lee),조종민(Jongmin Jo),차한주(Hanju Cha) 대한전기학회 2016 전기학회논문지 Vol.65 No.4
This paper proposed the voltage control of stand-alone inverter for power quality improvement under unbalanced and non-linear load. The 3-phase DC-AC inverter controls CVCF(Constant Voltage Constant Frequency) and selective harmonic eliminate method in stand-alone mode by PR controller, and the stand-lone inverter supplies stable sinusoidal voltage to balanced, unbalanced and non-linear loads. The total harmonic distortion(THD) of line-to-line load voltage(VLL) is 1.2% in the balanced load. THD of VLL is reduced from 5.2% to 1.4% and 6.7% to 3.5%, respectively unbalanced and non-linear load. The stand-alone inverter can be supplies sinusoidal balanced voltage to unbalanced load because the voltage unbalanced factor(VUF) of VLL is reduced from 5.2% to 1.4% in the unbalanced load. Feasibility of control method for a stand-alone inverter will be verified through 30kW stand-alone inverter system.
이우종(Lee, Woo-Jong) 대한건축학회 2014 대한건축학회논문집 Vol.30 No.9
The first purpose of this study is to find out the factors that gave jangsagak or sagak(pavilion keeping national annals) of Jeonjoksan sago(national archives storehouse) in Ganghwa island single-story elevation which was notably different from the other sagaks of local sagos that had double-story structure. The second purpose is to estimate the column arrangement and interior of jangsagak, which is indistinct for lack of historical materials. There were two factors that were possible to affect the single-story elevation of jangsagak; first, the influence of the building of Manisan sago, the former sago of Ganghwa island, which had diverted a single-story J aegung(purification house) to a storehouse; second, the need to consider the convenience of searching and carrying out the historical materials to perform the roll of substancial naesago(central storehouse of national archives). Unlike the contemporary rebuilt jangsagak, the side of original jangsagak is estimated to be composed of two or three kans at regular intervals of 2.7m. And, it is highly probable that original jangsagak had dense interior column arrangement. In both ends of jangsagak building, there could be lofts to adopt the advantage of double-story sagaks and to get the additional working area for the reference and taking out the historical materials.