http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
니코틴 중독의 단서노출치료를 위한 가상환경의 제작 및 욕구 유발 시험
김광욱 ( Kwang Uk Kim ),조원근 ( Won Geun Cho ),구정훈 ( Jeon Hun Ku ),김훈 ( Hun Kim ),김병년 ( Byoung Nyun Kim ),이장한 ( Jang Han Lee ),김인영 ( In Y. Kim ),이종민 ( Jong Min Lee ),김선일 ( Sun I. Kim ) 한국감성과학회 2002 추계학술대회 Vol.2002 No.-
Research has shown that many smokers experience an increase in the desire to smoke when exposed to smoking-related cues. Cue exposure treatment (CET) refers to the manualized, repeated exposure to smoking-related cues, aimed at the reducing cue reactivity by extinction. In this study, we constructed a virtual reality system for evoking a desire of nicotine, which was based on the results of a Questionnaire of Nicotine-craving. And we investigated the effectiveness of the virtual reality system as compared to classical device (pictures). As a result, we reached the conclusion that virtual reality elicits more craving symptoms than the classical devices.
조원근 ( Won Geun Cho ),김광욱 ( Kwang Uk Kim ),구정훈 ( Jeong Hun Ku ),이장한 ( Jang Han Lee ),김인영 ( In Y. Kim ),김선정 ( Sun Jeong Kim ),강윤주 ( Youn Joo Kang ),유태원 ( Tae Won Yu ),김선일 ( Sun I. Kim ) 한국감성과학회 2002 추계학술대회 Vol.2002 No.-
연구목적: 닌텐도 위를 이용한 가상현실기반 비디오게임 프로그램을 만성기 뇌졸중 환자에게 적용하여 균형능력 및 일상생활동작에 어떠한 영향을 미치는지 알아보고, 뇌졸중 환자의 재활프로그램으로서 적용 가능성이 있는지 알아보고자 한다. 연구방법: 만성기 뇌졸중 환자를 무작위로 가상현실기반 비디오게임 프로그램을 적용한 실험군(n=7)과 적용하지 않은 대조군(n=10)으로 구분하여 연구를 진행하였다. 연구에 참여한 모든 대상자에게 30분의 Bobath therapy와 15분간의 FES 치료를 기본적으로 실시하였다. 이에 더하여 실험군은 가상현실기반 비디오게임 프로그램을 1일 30분이내, 주 5회, 3주간 실시하였다. 대조군은 자전거 운동과 보행훈련으로 30분간 시행하였다. 실험 전 후 눈뜨고 외발서기(OLST; open leg standing test), Timed Up and Go(TUG) 검사, 10m 걷기 검사, Functional Independence Measure(FIM)를 측정하였다. 실험 전과 실험 후 측정값의 차이를 비교하기 위해 Wilcoxon Signed Ranks Test를 실시하였다. 그리고 각 측정값의 변화량에 대한 실험군과 대조군 사이의 차이를 알아보기 위해 Mann-Whitney U Test를 실시하였다. 연구결과: 실험결과는 다음과 같다. 1) 실험군에서는 FIM의 유의한 증가와 TUG, 10m 걷기 검사의 유의한 감소를(p<.05) 보였다. 대조군에서는 OLST의 증가와 TUG, 10m walking test의 감소가 나타났지만 통계적으로 유의하지 않았다. 오직 FIM에서만 유의한 증가가 나타났다(p<.05). 2) 실험 전 후의 실험군과 대조군의 각 측정값들의 평균차를 비교한 결과 실험군은 대조군보다 실험 전 후 OLST, TUG, 10m walking test 차이의 평균은 컸지만 통계적으로 유의하지 않았다. 결론: 이상의 결과로부터 가상현실기반 비디오게임이 만성기 뇌졸중 환자의 동적균형능력 및 일상생활동작 향상에 효과가 있음을 알 수 있었다.
폴리아닐린/탄소나노튜브 폴리머 액츄에이터의 모델링, 시뮬레이션 및 제어
손기원,이병주,김선정,김인영,김선일,Sohn, Ki-Won,Yi, Byung-Ju,Kim, Sean-Jeong,Kim, In-Young,Kim, Sun-I. 대한의용생체공학회 2007 의공학회지 Vol.28 No.3
Polymer actuators, which are also called as smart materials, change their shapes when electrical, chemical, thermal, or magnetic energy is applied to them and are useful in wide variety of applications such as microelectromechanical systems (MEMS), machine components, and artificial muscles. For this study, Polyaniline/carbon-nanotube polymer actuator that is one of electroactive polymer actuators was prepared. Since the nonlinear phenomena of hysteresis and a step response are essential considerations for practical use of polymer actuators, we have investigated the movement of the Polyaniline/carbon-nanotube polymer actuator and have developed an integrated model that can be used for simulating and predicting the hysteresis and a step response during actuation. The Preisach hysteresis model, one of the most popular phenomenological models of hysteresis, were used for describing the hysteretic behavior of Polyaniline/carbon-nanotube polymer actuator while the ARX method, one of system identification techniques, were used for modeling a step response. In this paper, we first expain details in preparation of the Polyaniline/carbon-nanotube polymer then present the mathematical description of our model, the extraction of the parameters, simulation results from the model, and finally a comparison with measured data.
맥파전달시간과 신체특징 파라미터를 이용한 수축기 혈압측정
이상민,박은경,김인영,김선일,Lee Sangmin,Park Eun Kyung,Kim In Young,Kim Sun I. 대한전자공학회 2005 電子工學會論文誌-SC (System and control) Vol.42 No.3
본 논문에서 맥파전달시간과 신체 특징 파라미터들을 이용하여 비침습적이고 연속적으로 혈압을 측정할 수 있는 방법을 제시하고 임상실험을 통하여 검증하였다. 맥파전달시간은 심전도와 광전용적맥파로부터 구한다. 맥파전달시간만 이용하여 개개인의 혈압을 측정하는 방법이 연구되었지만 이 방법은 모든 사람에게 적용 가능한 범용 회귀식을 도출하기 부족한 면이 있다. 이 연구에서 혈압과 관련되는 신체 특징 파라미터들과 맥파전달시간을 이용하여 모든 사람에게 적용 가능한 범용 회귀식을 도출하여 여러 사람들의 혈압을 측정하였다. 맥파전달시간만 이용하여 만든 회귀방법과 맥파전달시간과 신체 특징 파라미터들을 같이 이용하여 만든 회귀방법을 서로 비교 하였다. 실험 결과, 맥파전달시간과 신체 특징 파라미터를 이용하는 회귀방법이 여러 사람들의 혈압을 더 정확히 측정할 수 있다는 것을 알 수 있었고, American National Standards Institute of the Association of the Advancement of Medical Instrument(ANSI/AAMI)에 더 근접함을 알 수 있었다. In this paper, we proposed noninvasive and continous measurement of blood pressure using pulse transit time(PTT) and physical characteristic parameters and verified its clinical effectiveness. PTT can be obtained by electrocardiogram and phtoplethysmogram. There are many researches for estimating blood pressure using PTT which can be used for individual. However, it is not enough for extracting general regression equation which can estimate blood pressure for unspecified people. In this study, we suggested the regression equatin using PTT and physical characteristic parameters related to blood pressure and did measure blood pressure of many people. we compared the performance between two methods. As the results, we knew that the regressin model using PTT combined with physical characteristic parameters can estimate blood pressure more acurately and is closer to American National Standards Institute of the Association of the Advancement of Medical Instrument(ANSI/AAMI).
키토산/폴리디아릴디메틸암모늄클로라이드 전기감응성 고분바 하이드로겔의 굽힘 거동에서 물 상태에 따른 영향 분석
윤성길,김선정,김인영,김선일,Yoon, Seong-Gil,Kim, Seon-Jeong,Kim, In-Young,Kim, Sun-I. 대한의용생체공학회 2007 의공학회지 Vol.28 No.3
A interpenetrating polymer network (IPN) hydrogel, composed of chitosan (CS) and poly(diallydimethylammonium chloride) (PDADMAC) was prepared, which exhibited electrical sensitive behavior. The swelling behavior of the CS/PDADMAC SIPN hydrogel was studied by immersion of the gel into various pH buffer solutions, and their stimuli response in electric fields also investigated. In order to clarify the relationship between the equilibrium swelling ratio and bending behavior of the SIPN hydrogels, the state of water in the SIPN hydrogel was also investigated using differential scanning calorimetry (DSC).
시간 지연과 시변 상관성 제거 필터를 이용한 디지털보청기용 궤환제거 알고리즘
이상민,박영철,정세영,김인영,김선일,Lee, Sang-Min,Park, Young,Jung, Se-Young,Kim, In-Young,Kim, Sun-I 대한전자공학회 2005 電子工學會論文誌-SC (System and control) Vol.42 No.4
In digital hearing aid system, one of the main problems is acoustic feedback which is known as howling because of miniaturization md high-gain amplification. In this paper, we proposed a feedback cancellation algorithm for hearing aid using time delay and time-varying decorrelation filter. The proposed algorithm has a kind of adaptive filter structure, which is combined with time delay and time-varying decorrelation filter to improve feedback cancellation. An all pass filter was implemented as the time-varying decorrelation filter using low frequency modulator. From the result of computer simulation, it is verified that the proposed algorithm has good ability to cancel feedback. 디지털 보청기 시스템에서는 소형화, 고이득 증폭이 요구되는데 이로 인한 문제점 중의 하나가 하울링(howling)이라는 음향의 궤환이다. 본 논문에서는 시간지연과 시변 상관성 제거 필터를 이용하여 보청기에서 사용 가능한 음향 궤환 제거 알고리즘을 제안하였다. 제안한 알고리즘은 적응형 필터 구조를 기본으로 음향 궤환 신호 제거 효과를 증대시키기 위해 시간 지연과 상관성 제거 필터를 삽입하였다. 상관성 제거 필터로 사용된 전대역 통과 필터는 저주파 변조기를 이용하여 시변 특성을 갖도록 구현 하였다. 컴퓨터 시뮬레이션 결과를 통하여 제안한 알고리즘의 궤환 제거 특성이 우수함을 확인하였다.
의복형 초소형 발광모듈을 이용한 신경근육 자극 시스템 개발 및 임상적 효과 검증
박세형,이종실,김인영,김선일,Park, Se-Hyeong,Lee, Jong-Shill,Kim, In-Young,Kim, Sun-I. 대한의용생체공학회 2009 의공학회지 Vol.30 No.1
It can be used easily to reduce rehabilitation and treatment time if diagnostic and therapeutic devices are attached to cloth or body. Therefore we developed neuromuscular wearable ultra-miniature lighting modules which can improve the neuromuscular function and verified its clinical effectiveness. The system is based on the ultra-miniature lighting treatment module and there are two types of systems. One of them is designed as an attached type and the other type is combined with clothing. The wearable ultra-miniature lighting module is composed of controller (battery, MCU, bidirectional transmitter and receiver), cable, treatment medium generating device and other peripheral devices. To verify the clinical effectiveness of this device, we observed the difference of the strength of a muscle before and after 650nm and 25mW laser irradiation on the reflex point for 1 to 4 seconds. Among 48 patients having the degenerative osteoarthritis, the muscle strength before and after irradiation of laser was $21.8{\pm}7.99$ and $27.3{\pm}8.43$. According to the result, the muscle strength after treatment was significantly increased (p<0.01). To whom having difficulty in visiting to OPD(Out-Patient Department), doctors medically examine the patients and find the therapeutic point, attachment of this wearable ultra-miniature lighting module can function as self treatment (treating instrument) and treatment assist at home. If doctor can remotely control the patient and take part in treatment, the therapeutic device could contribute to prevention and care device.