      • Performance Evaluation of Early Streamer Emission Lightning Air Terminal

        Choi, Sang-Won,Her, Yong The Korean Society of Safety 2006 International Journal of Safety Vol.5 No.2

        Studies have claimed that ESE (Early Streamer Emission) air terminals offer a vastly increased zone of protection over that of traditional lightning rods (Franklin rods) by causing the emission of an upward streamer/leader: The upward streamer/leader will propagate towards the tip of the downward leader at an early stage in the attachment process.. This paper shows the results of a performance evaluation test of a particular type of the ESE air terminal (called "ElecHippo") with a simple rod tested at the Korea Electrotechnology Research Institute (KERI). The corona emission current of the ElecHippo made by Yong-Jin Enterprise Corp. has also been measured at the Occupational Safety & Health Research Institute (OSHRI). The results show that the ElecHippo meets the French standard of NFC 17-102-1995. The results also verify the ESE performance by measuring the ion emission current generated in the discharge electrode gap as a function of the capacitance and inductance of the equipped devices. Finally, we propose a new method for grounding the system to reduce the lightning damage by combining the ESE air terminal, the early discharge earth plate, the lightning strike recorder and the surge protection device.

      • KCI등재

        주요우울증이 근로자의 생산성에 미치는 영향 : WHO-HPQ(Health and Work Performance Questionnaire)를 이용한 예비연구

        김원,황태연,함병주,이준석,최병휘,김세주,서용진,강은호,우종민 大韓神經精神醫學會 2007 신경정신의학 Vol.46 No.6

        Objectives : Major depressive disorder (MDD) causes patients' distress and makes socioeconomic burden, both directly and indirectly. We used the concept of lost productive time (LPT) to estimate the indirect costs and calculated both absenteeism and presenteeism among workers with MDD. Mcthods : Depression group was recruited from workers visiting psychiatric outpatient clinic who had MDD without major physical or mental disorders (N= 106). Age and sex matched healthy control group was also recruited through advertisement (M=100). All participants completed a interview using WHO Health and Work Performance Questionnaire (HPQ), Job Stress Measurement Scale for Korean Employees, and Hamilton Rating Scale for Depression. Statistical analysis was performed with independent t-test or χ² test as characteristics of values (p=0.05). Results : The number of absence (0.94-day/month vs. 0.10-day/month, P=0.015) andthe numberofearly leaving (2.56-day/month vs. 0.24-day/month, P<0.001) were significantly higher in the depression group. Depression group evaluated their Perfor-mance level much lower than controls with significant value (5.16 vs. 7.62, P<0.001). In addition, depression group estimated their performance level during the last 4 weeks lower compared to the level of past 1-year (5.16 vs 6.63, P<0.001). The estimated costs of absenteeism in depression group were higher than controls by 2,520,000 Korean Won per year, and those of presenteeism were also higher by 4,880,000 Korean Won per year. The total costs of LPT in depression group were higher than controls by 7,400,000 Korean Won, which corresponds to 26% ofmean annual salary. In addition, the level of occupational stress, such as high demand and interpersonal conflict, was higher in the depression group. Conclusion : Major depressive disorder costs substantial productivity loss to workers and their company. Presenteeism imposes more time cost than absenteeism. Effectiveness trials are needed to devise cost-effective programs for the early detection and treatment of depression at the workplace.

      • KCI등재

        온수배관을 이용한 온실의 난방성능

        윤용철(Yong Cheol Yoon),신익수(Yik Soo Shin),김현태(Hyeon Tae Kim),배승범(Seoung Beom Bae),최진식(Jin Sik Choi),서원명(Won Myung Suh) (사)한국생물환경조절학회 2012 생물환경조절학회지 Vol.21 No.2

        본 연구는 온실의 난방 에너지 절감을 목적으로 온실 내부에 알루미늄 온수배관을 설치하여 난방효과에 대한 기초자료를 구축하고자 수행되었다. 그 연구결과를 요약하면 다음과 같다. 전체 실험을 포함하여 온실내의 높이별 온도편차는 4.0~7.0℃ 정도의 범위로서 그 차이가 크게 나타났다. 팬코일유니트(FCU)를 작동시킨 경우가 작동시키지 않은 경우에 비해 유출입수의 온도차가 3.3℃ 정도 크고, 소비전력량은 36.2~40.1% 정도 증가하였으며, 시간당 방열량은 44.6~52.0% 정도 증가하는 것으로 나타났다. 실험기간동안 순환유량은 0.48~0.49L · s<SUP>?1</SUP> 정도의 범위에 있었고, 평균유속은 1.53~1.56m · s<SUP>?1</SUP> 정도였다. 유출입수의 평균 온도차는 6.24~11.50℃이었다. 최저 외기온 ?14.0~?0.6℃ 범위에서 설정온도별 방열량은 135,930~307,150㎉ 정도의 범위로서 시간당 9,610~19,630㎉ · h<SUP>?1</SUP> 정도의 범위에 있었다. 이것은 최대난방부하의 약 23~53% 정도의 난방에너지를 공급할 수 있을 것으로 나타났다. 전체 방열량과 소비전력량은 각각 2,548,306㎉ 및 3,075.7㎾h이다. 화석연료인 경유로 난방할 경우, 소요되는 경유의 총 소비량은 281.6L 정도이고 비용은 321,000won인 것으로 나타났다. 농가용 전력요금을 적용하면 전력사용에 대한 총비용은 110,730won 정도로서 경유 소비 비용의 33.5% 정도로 나타났다. 실험구의 온도가 대조구보다 약 8.3~14.6℃ 정도 높게 나타났다. This research was conducted to obtain basic data with regard to the heating performance that would be produced by installing an aluminum hot water pipe inside the greenhouse with the goal of reducing the heating energy in greenhouse. The research results are summarized as follows. The degree of difference in relation to the temperature by height within the greenhouse during the entire experiment was significant - within the range of 4.0~7.0℃. The temperature difference between incoming and outgoing water was about 3.3℃ greater when FCU was activated compared to when it was not activated. Meanwhile, the amount of energy consumed increased about 36.2~40.1%. The amount of pyrexia per hour also increased by 44.6~52.0%. During the experiment period, circulated flux was within the range of 0.48~0.49 L · s<SUP>?1</SUP> while average fluid speed was 1.53~1.56 m · s<SUP>?1</SUP>. The average temperature difference between incoming and outgoing water was 6.24~11.50℃. The amount of heating value by each set temperature within the minimum outdoor temperature range of ?14.0~?0.6℃ was 135,930~307,150 ㎉, and the range was within the 9,610~19,630 ㎉ · h<SUP>?1</SUP> per hour. This demonstrated that about 23~53% heating energy of the maximum heating load could be supplied. Total radiating value and amount of energy consumed were 2,548,306 ㎉ and 3,075.7 ㎾h, respectively. When heating takes place using oil, which is a fossil fuel, the total amount of light oil consumed was 281.6 L while the cost was 321,000 won. When the electricity cost for farms is applied, the total cost was about 110,730 won, which is about 33.5% of the cost required compared to oil consumption. The temperature at in the experiment area was about 8.3~14.6℃ higher compared to that of the control area.

      • SCIESCOPUSKCI등재
      • T 세포활성항원 CTLA-4의 기능에 관한 연구 : T 세포에서 표적세포 살해능과 CTLA-4 발현과의 연관성 Target Cytotoxicity of T Cell Correlates with CTLA-4 Production

        노만택,조양자,김용식,최용,조보현,최장원,정용훈 大韓免疫學會 1996 大韓免疫學會誌 Vol.18 No.4

        CTLA-4, a T cell activation antigen and a homologue of CD28, was originally identified as a gene by a series of reverse genetic approaches. While CD28 molecule has been characterized well as a stimulator of T-cell function via enhanced lymphokines production and stablilization of those mRNA, most of the functions of CTLA-4 remain unknown. It has been widely accepted that CTLA-4 functions as an immune suppressor which is down-regualting the function of CD28. We previously showed that 34 KD form of this antigen mainly expressed CD8+ subset, a cytotoxic or suppressor, of activated peripheral blood lymphocyte. Based on our previous finding this study was conducted to further characterize immunological function of CTLA-4 especially in terms of involvement of this molecule in T-cell effector function mediating target cell cytotoxicity. 4 human T cell clones with different target cytotoxicities were employed in this study. NBL46 (CD4+) and NBL77 (CD8+) were cytotoxic and NBL32 (CD4+) and NBL58 (CD 8+) were non-cytotoxic to target LBF cell in target cell chromium release assay. And in Western blot assay 34 kD antigen was detected in NBL46 (CD4+) and NBL77 (CD8+) clones but not in NBL32 (CD4+) and NBL58 (CD8+) clones. It was summarized that expression of the CTLA-4 antigen was associated with cytotoxicity but not with subset phenotypes of T cells. In conclusion CD8+ T subset of PHA-stimulated PBL was major and only CTLA-4 producer and this molecule was induced during mid to late stage of T cell activation. The cytotoxicity of T cell clones to its target cell was directly correlated with its CTLA-4 production and vice versa. And it was highly suggested that primary function of CTLA-4 may involved in T cell effector function which mediates target cell killing.

      • KCI등재
      • KCI등재후보
      • SCIESCOPUSKCI등재
      • KCI등재후보

        유량변동에 따른 소양강유역 수질의 통계학적 해석

        최한규,백경원,최용묵,최진우 江原大學校 産業技術硏究所 2001 産業技術硏究 Vol.21 No.B

        This research was conducted with the aim of efficiently managing large scale of rivers such like Songyang-river through predicting water quality change with analyzing the characteristics of the flowing in nutrients and pollutants. The main result will be used as basic data for effectively operating reservoirs through controling water quality and quantity. The relationship between quantity of flow and water quality was analyzed and pollution loading into the basin was estimated. Three areas of Soyang-river upstream and one area of Suip-cheon in Yanggu-gun were selected as research sites. Flow and water quality were measured simultaneously. The relation between quantity of discharge and pollution concentration and between quantity of discharge and pollution loading were analyzed by statistical method, respectively. We provided a rating curve through measuring quantity of discharge(collection quantity of discharge)and pollutograph and pollution loading curve through water quality data. Also, we analyzed the correlation between quantity of discharge per unit area and pollution loading per unit area in each basin. As resurt of this research, Buk-cheon spot revealed an excellent first grade water quality for the items including BOD5, DO, and SS. The correlation coefficient between Buk-cheon spot's quantity of discharge and pollution loading was 0.896~0.996, showing the validity of analysis applying correlation curve formula of quantity of discharge and pollution loading in the same spot. Also, pollution loading per unit area of the items including BOD5, COD, DO, SS, T-N, T-P increased as area of basins get increased following the sequence of Buk-cheon, Suip-cheon, Naelin-cheon spots.

      • KCI등재후보

        월 PMP 개념의 적용에 관한 연구

        최한규,김남원,최용묵,윤희섭 江原大學校 産業技術硏究所 2001 産業技術硏究 Vol.21 No.B

        Normally at a flood season the operation of the dam depends on a short range weather forecast that makes many difficulties of the management at a dry season. It is needed to study the pattern of the long period rainfall. The concept of PMP(Probable Maximum Precipitation) was used for designing dam. From the concept, this study is applied the concept of monthly probable maximum precipitation for operating dam. It can be possible to let us know the appropriateness of a limiting water level at a rainy season. For the operation of dam at a dry season this study can predict roughly the flood season's pattern of precipitation by month or period, therfore the prediction of precipitation can rise efficient operation of a dam.