About RISS
RISS 처음 방문 이세요?
고객센터
RISS 활용도 분석
최신/인기 학술자료
해외자료신청(E-DDS)
RISS API 센터
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
쌍합탕 투약 후 수족부 저림증이 호전된 지주막하출혈 환자 증례보고
홍승철,민선우,문지성,김학겸,김영지,송주연,안립,신길조,최동준,Hong, Seungcheol,Min, Seonwoo,Moon, Jiseong,Kim, Hakkyeom,Kim, Youngji,Song, Juyeon,Ahn, Lib,Shin, Gil-cho,Choi, Dong-jun 대한중풍순환신경학회 2020 대한중풍학회지 Vol.21 No.1
■ Objectives This case is to report the effect of Ssanghap-tang on paresthesia of a subarachnoid hemorrhage patient. ■ Methods A male Korean patient was treated with Ssanghap-tang and acupuncture, moxibustion for total 30 days. We observed limbs numbness, circumferences, other symptoms such as weakness and any adverse event. ■ Results After treatment, numeric rating scale of limb numbness was improved to 5 from 8 at admission without any adverse event. However, we could not find any significant differences on hand circumference and limb weakness. ■ Conclusion This case suggests that Ssanghap-tang and acupuncture, moxibustion therapy could be effective in improving paresthesia of subarachnoid hemorrhage patient.
60 Hz 고압송전선로 인접 주거지역의 자기장 노출수준 평가
홍승철,정준식,김근영,박현주,최성호,Hong, Seung-Cheol,Jung, Joon-Sig,Kim, Keun-Young,Park, Hyun-Ju,Choi, Sung-Ho 한국환경보건학회 2008 한국환경보건학회지 Vol.34 No.1
'스콜라' 이용 시 소속기관이 구독 중이 아닌 경우, 오후 4시부터 익일 오전 9시까지 원문보기가 가능합니다.
In order to evaluate the magnetic field (MF) exposure level in residential areas near high voltage power lines, this research measured MF levels at 120 sites near high voltage transmission lines in the Busan region, Gwangju region, Daegu region and Changwon region from July to December, 2005, and compared and analyzed the efficiencies by measuring and applying the MF emission levels of underground cables and high voltage transmission lines. As a result of the investigation of the MF exposure level by the building usage, the average MF level of 17 locations at schools was $2.44{\pm}2.45mG;$ that of 10 locations at hospitals $6.21{\pm}12.39mG;$that of 76 locations at apartments $2.55{\pm}2.98mG;$ and that at kindergartens and infant houses $3.32{\pm}4.21mG$. MF exposure was analysed as a function of distance from the source and the MF levels directly below a source were $5.15{\pm}8.72mG$, those within 30 m were $3.10{\pm}3.32mG$, while those within 50 m were $2.45{\pm}2.38mG$, and within 100 m were $0.71{\pm}0.93mG$. In order to determine the difference of MF levels by the actual distance from high voltage transmission line within the same building, the evaluation of the floor position and the MF level has shown that the MF levels were highest in the order of roof, 4th floor, 3rd floor, 2nd floor and 1st floor. Comparison of MF emission intensity of underground cables and high voltage transmission lines, has shown that underground cables have an 86-94% of reduction ratio in MF compared to high voltage transmission lines, thus demonstrating higher efficiency.
홍승철 대한임상노인의학회 2011 대한임상노인의학회지 Vol.12 No.3
'스콜라' 이용 시 소속기관이 구독 중이 아닌 경우, 오후 4시부터 익일 오전 9시까지 원문보기가 가능합니다.