
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
광음향 분광학을 이용한 화학작용제의 실시간 검출에 관한 연구
허미라 육군사관학교 화랑대연구소 2017 한국군사학논집 Vol.73 No.1
There is growing interest and needs about fast, accurate, and real-time detection methods of Chemical Warfare Agent(CWA). The conventional detection methods have a fatal drawback, complex and unnecessary sample preparation process. In addition, it is impossible to directly detect optically opaque materials. The aim of this paper is a real-time and direct detection of chemical weapons without sample preparation process based on FTIR-PAS(Fourier Transform Infrared- Photoacoustic Spectroscopy) system. Based on photoacoustic effect, photoacoustic spectroscopy (PAS) is unique form of spectroscopy which measures an acoustic signal caused by optical absorption. It is possible to directly determine and identify chemicals without sample preparation using PAS. We explain in detail the theoretical background and present experiment results according to the sample phase and condition. We acquired PA spectra of Simulant CWAs without sample preparation process. Through comparative analyses with the FTIR spectra, we have verified the possibility of direct real time detection, and high accuracy of the FTIR-PAS system. In conclusion, due to independence to the phase and condition of sample and no need for sample preparation processes, we have shown the advantages of PAS in terms of detection time and efficiency. 1995년 일본 도쿄 지하철 사린사건, 2013년 시리아 정부군의 화학무기 공격 등 여전히 인류는 화학무기의 위협속에 노출되어있다. 특히 북한은 사린과 타분 등 화학무기를 2천~5천 톤까지 보유하고 있다고 추정되고 있다. 이러한 위협속에서 우리는 화학작용제를 신속하고 적확하게 탐지하고자 하는 노력을 지속적으로 실시하고 있다. 현재까지 개발된 화학작용제의 탐지기술은 변색법과 같이 아주 간단한 방법부터 이온이동도법과 같이 복잡한 원리를 포함한 방법 등 매우 다양하게 발전되어왔다. 하지만 이러한 기술들이 모든 상황에 완벽하게 적용되어지지 않는다. 특히, 현존하는 기술들은 현장에서 즉각적인 검출이 어렵고, 실험실 환경에서 전처리과정이 필수적이다는 단점을 갖고 있다. 본 연구에서는 광음향 분광학에 대해 이론적으로 설명하고, 광음향 분광법(photoacoustic spectroscopy)을 이용하여, 전처리 과정을 제거한 화학작용제의 실시간 검출에 대한 연구를 통해 보다 간단하고 편리하면서, 높은 정확도의 실시간 분광 시스템을 구현하였다. 특히, 광학적으로 불투명한 시료에 대해서 시료 상태나 형태에 구애받지 않고, 즉각적이고 실시간으로 검출 할 수 있는 분광학적 방법을 정립함으로써, 현장에서 in situ detection의 가능성을 확인하였다. 모의 화학작용제 2종류를 구현한 퓨리에 변환 광음향 시스템을 통해 광음향 스펙트럼을 측정하였고, 이를 FTIR 스펙트럼과 비교하였다. 정성분석 결과, 스펙트럼이 모두 일치하여, 시스템의 정확도를 확인하였으며, 화학작용제의 즉시 검출이 가능함을 확인하였다.
허미라,정인철 한국화재소방학회 2022 한국화재소방학회논문지 Vol.36 No.3
This study aims to develop an educational program for peer psychological support in the fire officials’ organization. Theprogram was developed through goal setting, component derivation, pilot study, model design, and effectiveness verification. Forty fire officials were divided into an experimental group and a control group of twenty people each. The program wasconducted with a total of twelve sessions. Empathy, self-reflection, and interpersonal skill levels were examined before andafter the program. The results indicated that the levels of empathy and self-reflection of the experimental group weremeaningfully improved (F = 5.96, 5.45, p < .05) compared to the control group, but interpersonal relationship was not (F= 2.88, p < .05). This study makes a meaningful contribution through developing of program using a scientific andsystematic method in the field of psychological education and counseling. 본 연구는 소방공무원을 위한 동료심리지원 교육프로그램을 개발하고 그 효과성을 검증하고자 하였다. 프로그램은 목표설정, 구성요인 도출, 예비연구, 프로그램 모형 구안, 효과성 검증의 절차를 거쳐 개발되었다. 소방공무원 40명을 대상으로 실험집단 20명, 대조집단 20명으로 나누어 총 12회기로 구성하여 진행하였고, 프로그램 전과 후 참가자의 공감, 자기성찰, 대인관계능력을 분석하였다. 연구결과, 교육 참가자들의 공감과 자기성찰은 대조집단에 비해의미있게 향상(F = 5.96, 5.45, p < .05)되었고, 대인관계능력은 프로그램의 효과가 미비한(F = 2.88, p < .05) 것으로나타났다. 이는 본 연구의 프로그램 구성 요인들이 동료상담자의 개인 내적 성장에 보다 비중을 두고 있어 타인과의상호 작용 요소를 포함하는 능력에는 효과가 적었던 것으로 보인다. 본 연구는 동료심리지원을 하는 소방공무원의상담자 역할에 초점을 두고 심리교육 및 상담의 영역에서 과학적이고 체계적인 개발 절차를 통해 프로그램의 효과를 검증했다는데 의의가 있다.
월터 크레인 그림책 일러스트레이션의 장식 표현을 응용한 네일 디자인
허미라,최정순 한국니트디자인학회 2020 패션과 니트 Vol.18 No.1
Various forms of transformation and creative development of design on the expression of differentiated beauty of nail management continue in modern times. With these developments, efforts have been made to find designs and motifs in various art historians. Among the design motifs, Walter Crane’s picture book illustration has delicate and attractive motifs based on various Arnubo styles, making it a highly useful element as a delicate design element of nail art. The decorative features shown in detailed and meticulous Walter Crane’s picture book illustration are expressed using nature-based flower forms, stems, organic animals and plants, similar to the Arnubo form, while decoration gives new value to straight lines, curves, proportion and lettering. The feminine and organic forms of motifs and repeated patterns in the costumes in the illustration of Walter Crain are characterized by complex yet decorative features. These decorative features were transformed into concise designs that were incorporated into nails and the decorative elements shown in objects in space were expressed in refined yet luxurious images with the harmony of straight lines and curves.
Chatbot as a New Business Communication Tool: The Case of Naver TalkTalk
허미리,이경전 한국경영커뮤니케이션학회 2018 Business Communication Research and Practice Vol.1 No.1
Objectives: Chatbot is a program that talks in voice or text. It is equipped with artificial intelligence (AI) technology and is developed in a way to combine with messenger, offering companies new opportunities for business communication. Companies expect cost savings and sales increases by providing chatbot-based services to their customers, such as providing responses to inquiries and fulfilling orders without time constraints. However, the current absence of conversationally perfect AI technology creates a climate in which the public holds unreasonable expectations, as businesses fail to understand the current status of AI and the marketing of chatbot technology companies is hyped. Methods: This is a single-case study. While looking for a successfully deployed chatbot, we found Naver TalkTalk, a card-based chatbot application. We interviewed Naver’s managerial and technical staff four times and acquired internal data as well as external data. Results: We illustrate Naver TalkTalk, a successful card-based business chatbot, and examine how Naver TalkTalk has developed and evolved for effective business communication. The first chatbot started without automation and then failed in the process of evolving to automation. This chatbot was changed to cardbot and was re-automated based on the card-based interface and robotic process automation (RPA). Conclusions: The cardbot-based chatbot is quick and easy to handle, which is why it has been popular among users. It is now becoming a new business communication channel to attract new customers. In addition, the proper automation of business communication is increasing efficiency and reducing costs of businesses.
알코올의존성의 객관적 표지자로서 탄수화물결핍 트랜스페린의 진단적 유용성
허미나,이규만,신동훈,조현찬,김승겸,최인근 대한진단검사의학회 2004 Annals of Laboratory Medicine Vol.24 No.1
Background : Biochemical markers can provide objective evidence of heavy alcohol drinking. In this study, we investigated the diagnostic usefulness of carbohydrate-deficient transferrin (CDT), a relatively new marker of alcohol consumption. Methods : We consecutively enrolled 81 participants aged between 28 and 69 years, consisting of 44 alcohol-dependent patients and 37 age-matched controls. Relative values (%) of CDT were determined in their sera with turbidimetric immunoassay (Bio-Rad %CDT assay, Axis-Shield ASA, Oslo, Norway), and were compared with two conventional markers of alcohol consumption, gammaglutamyl transferase (GGT) and mean corpuscular volume (MCV). Results : The distribution patterns of %CDT among alcohol-dependent patients and controls were significantly different from each other (P=0.0000). Of the 44 alcohol-dependent patients, positive results of %CDT (≥2.6%), GGT (>50 IU/L), and MCV (>98 fL) were observed in 43 (97.7%), 35 (79.5%), and 24 (54.5%) patients, respectively. The areas under the receiver operating characteristic (ROC) curves (95% confidence interval) for %CDT, GGT, and MCV were 0.995 (0.946-1.000), 0.894 (0.805-0.951), and 0.768 (0.661-0.855), respectively. Discrimination between alcohol-dependent patients and controls, as measured by the areas under the ROC curves, was significantly better for %CDT than for GGT and MCV (P=0.000 and P=0.006, respectively). Conclusions : CDT seems to be the most reliable of the three markers tested for chronic alcohol consumption, and it may provide a useful information to for the objective detection of alcohol-dependent patients. (Korean J Lab Med 2004; 24: 40-4) 배경 : 생화학적 표지자들은 알코올과다섭취에 대한 객관적 증거를 제시할 수 있다. 본 연구에서는 알코올섭취에 대한 새로운표지자인 탄수화물결핍 트랜스페린(carbohydrate-deficient trans-ferrin,CDT)의 진단적 유용성을 평가하였다. 방법 : 연구대상은 모두 81명이었으며, 나이는 28세에서 69세까지 분포하였다. 환자군에는 4명의 알코올의존성 환자, 대조군에는37명의 정상인이 포함되었다. 이들의 혈청에서 면역비탁법(Bio-Rad %CDT assay, Axis-Shield ASA, Oslo, Norway)으로 CDT의 상대치인 %CDT를 측정하고, 기존에 알려진 알코올섭취의 표지자들인 gamma-glutamyl transferase (GGT) 및 평균적혈구용적(mean corpuscular volume, MCV)과 비교하였다. 결과 : %CDT의 분포는 환자군과 대조군 사이에 유의한 차이가 있었다(P=0.0000). 환자군에서 %CDT, GGT, MCV의 양성률은 각 97.7% (43/44), 79.5% (35/44), 54.5% (24/44)로 관찰되었다. %CDT, GGT, MCV에 대한 수신 자동작곡선의 아래면적(95% 신뢰구간)은 각 0.995 (0.946-1.000), 0.894 (0.805-0.951), 0.768 (0.661-0.855)이었다. 수신자동작곡선의 아래면적으로 구한 알코올의존성 환자군과 대조군 간의 변별력은 %CDT에서 GT와 MCV에 비해 통계적으로 유의하게 양호하였다(각각의P=0.006 및 0.000). 결론 : CDT는 만성 알코올섭취에 대한 가장 신뢰할 수 있는 표지자로 생각되며, 알코올의존성 환자들의 객관적 검출에 유용하게 쓰일 수 있을 것이다.
C형 간염 바이러스 항체 검출용 ADVIA Centaur HCV 측정법의 평가:AxSYM HCV Version 3.0 측정법과의 비교
허미나,강희정,강성하,이규만 대한진단검사의학회 2005 Annals of Laboratory Medicine Vol.25 No.3
Background : The detection of antibody to hepatitis C virus (anti-HCV) is the most useful method to investigate past or current HCV infections. We performed a clinical evaluation of ADVIA Centaur HCV assay, a new third generation assay for the qualitative detection of IgG antibody. Methods : Included in the study were a total of 323 samples (108 positive and 215 negative), for which HCV reverse transcription polymerase chain reaction (RT-PCR) was requested. ADVIA Centaur HCV assay (Bayer Healthcare LLC, Diagnostics Division, Tarrytown, NY, USA) was compared with a currently available and widely used AxSYM HCV version 3.0 assay (Abbott Laboratories, Abbott Park, IL, USA). Samples with discrepant results were retested with each assay, and further tested with a recombinant immunoblot assay (RIBA, LG HCD Confirm, LG Chemical Co., Seoul, Korea). Reproducibility of Centaur assay was evaluated in five groups (two samples in each group) with different index values. Results : The overall concordance rate was 91.6% (296/323) between Centaur and AxSYM assays. It was 100% (108/108) in RT-PCR positive samples and 87.4% (188/215) in RT-PCR negative samples. Discrepant samples (8.4%, 27/323) were all RT-PCR negative, and all except two were Centaur negative and AxSYM positive. In discrepant samples, RIBA showed negative results except for two samples with indeterminate results. The sensitivity and specificity of Cenyaur assay were 98.1% and 65.6%, and the respective figures for AxSYM assay were 98.1% and 54.9%. Reproducibility of Centaur assay was satisfactory. Conclusions : The overall concordance between Centaur and AxSYM assays was satisfactory. Sensitivity and specificity of Centaur assay were equivalent to or better than those of AxSYM assay. ADVIA Centaur HCV assay seems to be a reliable and useful method for the detection of anti-HCV in clinical laboratories. 배경 : C형 간염바이러스(HCV) 항체 검사는 과거 및 현재 감염 여부를 조사하기 위해 시행할 수 있는 가장 유용한 방법이다.본 연구에서는 새로 개발된 3세대 면역검사법인 Bayer사의 Cen-taur HCV 항체 검사의 임상적 유용성을 평가하고자 하였다.방법 : HCV 역전사중합효소연쇄반응(RT-PCR)이 의뢰된323검체(양성 108검체와 음성 215검체)를 대상으로 Centaur HCV항체 검사(Bayer Healthcare LLC, Diagnostics Division, Tar-rytown, NY, USA)와 AxSYM HCV 항체 검사(version 3.0,Abbott Laboratories, Abbott Park, IL, USA)를 시행하였다.검사 결과에 불일치를 보인 검체들은 각 시약으로 재검을 하고LG HCD Confirm (LG 화학, 서울, 대한민국) 시약으로 면역블롯검사(RIBA)를 시행하여 확인하였다. Index 수치에 따라 나눈 5군에서 각각 2검체씩을 선택하여 Centaur 측정법의 재현성을 평가하였다.결과 : Centaur와 AxSYM HCV 항체 검사 간의 일치율은91.6% (296/323)였고, RT-PCR 양성 검체에서는 100% (108/108), 음성 검체에서는 87.4% (188/215)였다. 불일치 검체(8.4%,27/323)는 모두 HCV RT-PCR 음성이었고, 2예를 제외하고는Centaur 음성이면서 AxSYM 양성 결과를 보였다. 불일치 검체들에 대한 RIBA 결과는 불확정 결과를 보인 2예를 제외하고 모두 음성이었다. Centaur HCV 항체 검사의 민감도와 특이도는98.1%와 65.6%였고, AxSYM 검사법에서는 각각 98.1%와 54.9%였다. Centaur 검사법의 재현성은 우수하게 관찰되었다. 결론 : 두 항체 검사 간의 전반적 일치율은 양호한 범위에 속하였다. Centaur HCV 항체 검사의 민감도와 특이도는 AxSYM 검사법과 비교할 때 이에 상응하거나 다소 우수하였다. Centaur HCV항체 검사는 HCV 항체 검출을 위한 유용한 방법으로 평가된다.