
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
유두 분비물을 원인으로 하여 시행한 Galactography의 유용성에 관한 고찰 : Mammography, Breast sonography와 비교
조희정(Hee Jeong Jo),전해경(Hae Kyeong Jeon),김서현(Seo Hyeon Kim),최진희(Jin Hee Choi),권순안(Soon An Kwon),민관홍(Kwan Hong Min),김성룡(Seong Ryong Kim) 대한영상의학기술학회 2009 대한영상의학기술학회 논문지 Vol.2009 No.-
Purpose : To evaluate the usefulness of galactography compared with mammography and breast sonography in patients with nipple discharge. Materials and methods : This study was retrospectively conducted in 79 patients with nipple discharge who underwent galactography in our hospital from April in 2004 to July in 2008. Telebrix was used as a contrast medium There were digital mammography (GE Senography TM 2000D) and sono medical system (Philips Medical system, Bothwll, WA / HDl-5000, iU22) as a device for this study. First of all, we accessed Galactography, Mammography and breast sonography using BI-RADS classification and analyze pathology from surgery and biopsy over BI-RADS C3 lesion. The last, we find out the availability of galactography compared with pathology and analyzed the result of galactography. Results : Among 79 patients who underwent galactography, 55 were revealed as over BI-RADS C3 lesion. In mammography, 20 of that 55 were normal as Bl-RADS C1 or C2 lesion, other 12 were diagnosed as BI-RADS C1 or C2 lesion, then recommended further study. In breast sonography, 43 of 55 were consistent with BI-RADS C3 lesion. 9 were not found the lesion in mammography and breast sonography, but found the suspicious lesion in galactography. Conclusion : Galactography is useful for the patient with nipple discharge diagnosed breast disease, especially intraductal papilloma (IDP).
직접 및 간접변환 방식의 디지털 유방 X선 촬영시스템의 영상화질 비교 연구
박혜숙,오유나,조희정,김상태,최유나,김희중,Park, Hye-Suk,Oh, Yu-Na,Jo, Hee-Jeong,Kim, Sang-Tae,Choi, Yu-Na,Kim, Hee-Joung 한국의학물리학회 2010 의학물리 Vol.21 No.3
The purpose of this study is to comprehensively compare and evaluate the characteristics of image quality for digital mammography systems which use a direct and indirect conversion detector. Three key metrics of image quality were evaluated for the direct and indirect conversion detector, the modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), which describe the resolution, noise, and signal to noise performance, respectively. DQE was calculated by using a edge phantom for MTF determination according to IEC 62220-1-2 regulation. The contrast to noise ratio (CNR) was evaluated according to guidelines offered by the Korean Institute for Accreditation of Medical Image (KIAMI). As a result, the higher MTF and DQE was measured with direct conversion detector compared to indirect conversion detector all over spatial frequency. When the average glandular dose (AGD) was the same, direct conversion detector showed higher CNR value. The direct conversion detector which has higher DQE value all over spatial frequency would provide the potential benefits for both improved image quality and lower patient dose in digital mammography system.