http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
모드정합법을 이용한 20GHz 저손실 이중모드 채널여파기
정근욱,이재현,유경완,강성춘 대한전자공학회 1997 電子工學會論文誌, D Vol.d34 No.10
In this paper, we present a 20 GHz low-loss dual-mode channel filter designed by using mode matching method. The performance of dual-mode channel filter mainly depends on iris characteristics. Therefore the exact design of iris is the key point to get good frequncy response of the filter. MOde matching technique is widely used ot design several kinds of waveguide filters because it is simple in theory and can easily calculate the scattering matrices at the discontinuities with simple structure like iris coupled filters. Additionally the effect for finite thickness of the iris in the dual-mode cavity iflter is analyzed by te full-wave method, providing the exact filter implementation without trial and error.
변형된 TE$_{113}$/TM$_{012}$ 삼중모드 도파관 대역통과여파기의 구현
정근욱,이재현,박광량,김재명 대한전자공학회 1996 전자공학회논문지-A Vol.33 No.11
In this paper, a modifed TE$_{113}$/TM$_{012}$ triple-mode bandpass filter is implemented by using a modified inter-cavity iris in which the number of slots are reduced upto 50%. In a coventioanl iris two prirs of slot apertures are used to independently couple three resonant modes between two adjacent cavities. However, if transverse magnetic polarizability of a pair of veritcal slot apertures is used to control weak horizontal TE$_{h}$-TE$_{h}$ mode coupling, the width of novel iris slots would substitute for the slot length of the conventional iris, causing to eliminate the horizontal slot apertures. The measured data of two filters, which are the modified filter and ocnventional one, are compared. Experimental result shows that the characteristics of the novel triple-mode filter matches well that of the conventional filter.
고급 산화법과 생물학적 방법을 이용한 TCE 분해에 관한 연구고찰
정근욱 경주대학교 건설환경연구소 2003 建設環境論叢 Vol.- No.5
고급산화법(advanced oxidation process)에서 O_(3), O_(3)/pH AOP 및 O_(3)/H_(2)O_(2) AOP 및 공정에 의한 TCE(Trichloroethylene)처리성과 처리조건이 조사되었다. TCE농도변화에 따른 오존처리 효과를 평가한 결과 초기농도가 높을수록 오존이용률과 TCE제거량이 증가하였다. 60ppm TCE에 대하여 pH변화에 의한 TCE제거율 변화를 비교한 결과pH7과 10에서 거의 동일한 속도로 제거되었다. O_(3)/H_(2)O_(2) AOP공정에서 과산화수소와 오존과의 무게비(O_(3)/H_(2)O_(2) AOP (W/W)ration)가 약 0.8일 때 TCE제거속도가 가장 빠른 것으로 나타났다. O_(3)/pH AOP와 달리 pH10에서 TCE제거속도가 가장 느렸으나 pH7에서 O_(3)/pH AOP는 O_(3)/H_(2)O_(2) AOP 보다 더 효과적으로 TCE를 제거할 수 있었다. 적절한 조건하에서 O_(3)/pH AOP는 고농도 TCE처리에 매우 효율적인 방법으로 사용될 수 있다. 이산화티타늄에서 졸-겔법으로 유기화합물의 광분해반응용 TiO_(2)광촉매 상에서의 TCE의 광분해 반응특성을 조사하였다. 여기서 용존산소의 농도가 증가할수록 반응속도는 빨라졌으며 용액의 pH는 거의 영향을 미치지 못하였다. 반응 후 생성되는 염소이온을 분석한 결과 반응한TCE가 완전한 CO_(2)와 HCI로 분해되지 않고 일부는 다른 부산물로 ehol는 것으로 생각되었고 용존산소의 농도가 증가할수록 부산물의 생성량은 감소하였다. 생물학적 방법중 가용성 메탄산화효소를 분비하는 혼합메탄자화균총 MM을 이용하여 난분해성 유기용제인 TCE를 분해하였다. MM의 배양액(O.D_(660)=4.5)을 이용하여 5ppm의 TCE를 20시간만에 완전분해하였다. 30ppm이상의 TCE는 MM의 메탄소모율을 저하 시켰으며, 한편 3ppm의 TCE를 세시간 처리하였을 때 84%의 분해율을 보였으나 1μM의 구리가 존재할 경우는 저해작용으로 인해 68%의 분해율을 보였다. 탈염소화를 이용한 생물학적 분해는 난분해성 물질로 알려진 PCE를 생물학적으로 처리하기 위해 혐기성 회분식실험을 수행하였으며, 상호대사를 통해 일어나는 PCE의 탈염소화 속도를 비교하기 위해 1차기질의 영향을 조사하였다. 회분식 실험을 수행한 결과 혐기성 미생물에 의해 PCE가 환원적 탈염소화반응을 통해 TCE로 변화되고 TCE가 다시 탈염소화 반응을 통해 제거되는 것을 관철되었다. 이러한 탈염소화 반응은 메탄이 발생하는 시기에 진행되었다. 1차기질에 따른 PCE의 탈염소화 반응속도를 비교해보기 위해 글루코스, 메탄올과 아세트산염을 사용한 결과 아세트산이 가장 좋은 1차기질로 나타났다.
정근욱,우선희,김재정,한석순,김홍기,최곽순,김인수,이상성,이경호 한국환경농학회 2006 한국환경농학회지 Vol.25 No.1
This study was initiated to evaluate the inhibitory effect of selected heavy metals on the growth of Acinetobacter sp. known as one of the phosphorus accumulating microorganisms (PAO) involved in the enhanced biological phosphorus removal (EBPR) process of the wastewater treatment plant. Acinetobacter sp. was initially selected as a starting model microorganism and was grown under aerobic condition for this experiment. The heavy metals selected and investigated in this study were cadmium (Cd), copper (Cu), mercury (Hg), nickel (Ni), and zinc (Zn). Median (IC50) and threshold (IC10) inhibitory concentrations for Cd, Cu, Hg, Ni, and Zn were 2.95 and 1.45, 4.92 and 2.53, 0.03 and 0.02, 1.12 and 0.43, 14.84 and 5.46 mg L-1, respectively. We demonstrated that most of heavy metals tested in the experiment inhibited the growth of Acinetobacter sp. in the range of predetermined concentrations. Based on the data obtained from the experiment, Hg was the most sensitive to Acinetobacter sp., then Ni, Cd, Cu, and Zn in order.
골프장의 잔디 토양에서 살균제 Tolclofosmethyl의 분해
정근욱,우선희,김흥태,사동민,김영기,홍순달,김재정,이재구 한국환경농학회 2004 한국환경농학회지 Vol.23 No.3
Tolclofosmethyl (TCFM) is heavily and annually applied to the turf soils of most golf courses in Gyeongju to control the fungi known to cause the disease brown patch. The soil samples used for the experiment was collected three weeks after the annual application at the end of May in the year 2002. The preliminary results obtained from this study demonstrated that the repeated field annual applications of TCFM to the turf soils of a golf course located in Gyeongju city in the southern area of Korea showed the enhanced degradation of the parent compound TCFM, especially in the surface (0~15 cm) soil rather than the shallow subsurface (15~30 cm) and deep subsurface (30~45 cm) soils, compared to the corresponding surface (0~15 cm) and shallow and deep subsurface (15~30 cm and 30~45 cm) soils of the untreated plot. It appears that microorganisms in the soil may be involved in the enhanced degradation of TCFM.
Iris 전송손실 측정값을 이용한 이중모드 협대역 도파관 채널여파기의 설계 및 제작
정근욱,이재현 대한전자공학회 1995 전자공학회논문지-A Vol.32 No.6
In this paper, measured iris transmission loss data and simulated data by using 3-dimension full-wave analysis S/W are presented and compared with Marcuvitz's theory. And by using measured iris data, dual-mode narrow-band channel filters can be successfully implemented. This paper shows that there is severe difference between the transmission loss of iris calculated by using Marcuvitz's equation to calculate iris dimension, if the length of slot iris is longer than .lambda./.pi., and in the long urn the response of channel filter is distorted. Experimental result shows that the characteristic response of implemented channel filter by using the iris transmission loss graph presented here matches well the design specfications. In conclusion, iris transmission loss measurement method will be very useful to design channel filter.