GIS 감시진단용 다양한 센서를 적용한 PD 검출 및 패턴분석 결과 비교연구
이지철,구자윤,장용무,최재옥,연만승 대한전기학회 2005 전기학회논문지C Vol.54 No.5(C)
Many precedent investigations have been made for the reliable assessment of the insulation state of large power apparatus for which partial discharge detection is one of the plausible way. In this work, experimental investigations have been carried out to make the comparison on the PD(partial discharge) pattern analysis related to the five different types of artificial defects such as SFMP (Single Free Moving Particle), MFMP (Multi Free Moving Particle), Void, CFP (Conductor-Fixed Protrusion), EP (Enclosure Protrusion). For each PD pattern, PD detection has been done by three different types of PD sensors such as HFCT(High Frequency Current Transformer), AE(Acoustic Emission) and UHF(Ultra High Frequency). And, in addition, frequency spectrum by the UHF sensor has been also made for each defect respectively. As a result, it is observed that the possibility of obtaining PD pattern based on PRPD(Phase Resolved Partial Discharge) in connection with the defects under investigation is dependant on the type of the sensor while the spectrum analysis is always successful to be achieved for every defect. Therefore, it could be suggested that the nature of PD source can be identified more distinctively when the conventional PRPDA is combined with spectrum analysis.
입력전압 가변 및 동작 모드 변화를 통해 넓은 출력전압 범위에서 동작하는 LLC 공진컨버터
이지철,주종성,허예창,마리우스,김은수,전용석,국윤상 전력전자학회 2017 전력전자학회 논문지 Vol.22 No.6
In this paper, we propose an LLC resonant converter that operates over a wide controllable output voltage (50 VDC to 800 VDC) and shows high efficiency characteristics under all load conditions and output voltages. Two 3.3kW prototypes are designed for an experimental comparison between the variable frequency control (control scheme 1) and the variable input voltage(VIN) control (control scheme 2) mechanisms. The experimental results show that the variable input control mechanism demonstrates high efficiency under all loads and output voltages.
군 간부 건강검진 결과를 통한 검사항목 품질향상에 관한 연구
이지철,이종형,양남영,강경희,박아르마,김광환 한국융합학회 2017 한국융합학회논문지 Vol.8 No.6
본 연구의 목적은 군 간부건강검진결과를 분석하여 군 간부의 건강상태를 파악하고자 하는 것이다. 연구결과는 다음과 같다. 첫째, 연구대상자의 일반적 특성은 전체 120명의 연구대상자 중, 40세 미만이 60명, 40세 이상이 60명인 것으로 나타났다. 둘째, 연구대상자의 연령 및 체질량 지수와 검사결과간의 정준상관분석 결과, 3개의 정준함수가 도출되었다. 이 중, 2개의 정준함수가 각각 통계적으로 유의한 것으로 나타났다. 본 연구에서 군 간부에게는 건강에 대한 총체적 진단과 검진제도가 보완되어야 한다는 의미 있는 결과가 도출되었고, 향후 군 간부에 대한 건강검진은 확대된 건강검진 품질에 대한 추가 검사항목을 받아야 하며, 이를 위한 예산반영은 정책 관련기관에서 판단하여야 할 것으로 사료된다. The research study focuses to analyze the result of the military personnel medical examination and identify the medical conditions of military individuals. The results of this study are as follows. First of all, for the general features of research subjects, there are 60 people who are 39-year-old or less and 60 people in the age of 40-year-old or over of the total 120 research subjects. Secondly, as a result of canonical correlation analysis in between their ages/body mass index(BMI) and the outcomes of medical examination, it derived 3 canonical functions. 2 of the functions out of the 3 demonstrated statistical significance. The research has conjured meaningful results which include that the holistic diagnosis and treatment system for the military officers needs additional enhancement. Also the medical examination is in desperate need of expansion in test items and the associated budget planning should be evaluated in government organizations related to welfare policy.
이지철,민경식 한국항해항만학회 2010 한국항해항만학회지 Vol.34 No.1
This paper describes patch antenna design method of antenna high gain and broad bandwidth using cylindrical magneto material around feeding line. Strong current induction method applied combination to generate magnetic fields around feeding line for antenna high gain characteristic and principle of PIFA designed application for design of antenna broadband. In case of single CMM, gain increased 3.96 dB compare with the reference antenna gain however bandwidth characteristic not increased compare with the reference antenna. In case of dual CMM, gain improved about 10 dB compare with the reference antenna and - 10 below bandwidth is 700 MHz(50 MHz ~ 750 MHz) with this paper designed high gain characteristic. 본 논문은 패치 안테나의 급전선 주위에 원통형 자성체을 이용하여 안테나의 고이득 및 광대역 안테나 설계법에 대해서기술한다. 안테나의 고이득 설계를 위해서 급전선 주위에 생기는 자기장과 원통형 자성체 주위에 생기는 자기장을 결합시켜 급전선에강한 전류를 유도시키는 방법을 사용하였고, 안테나의 광대역 설계를 위해서 shorting 스터브를 추가한 PIFA의 원리를 적용하여 설계하였다. 단일 원통형 자성체의 경우, 참고 안테나와 비교하여 3.96 dB 이득이 증가하였으나 대역폭 특성은 개선되지 않았다. 이중 원통형자성체의 경우, 참고 안테나와 비교하여 이득은 약 10 dB 개선되었으며, - 10 dB 이하 대역폭은 700 MHz(50 MHz ~ 750 MHz)로써광대역 특성을 가지는 안테나를 설계하였다.
칩과 안테나 사이 연결부 보호를 위한 RFID 태그 안테나의 광대역 설계
이지철(Ji-Chul Lee),민경식(Kyeong-Sik Min) 한국전자파학회 2009 한국전자파학회논문지 Vol.20 No.2
본 논문은 칩과 안테나 사이의 연결부 보호를 위한 RFID 태그 안테나의 광대역 설계에 대해서 기술한다. 제안된 태그 안테나의 크기, 공진 주파수 그리고 대역폭은 각각 53×10×1 ㎜, 900 ㎒이고, ?10 dB 이하에서 800 ㎒(500~1,200 ㎒)이다. 폴리에틸렌, 유리 그리고 실리콘과 같은 다른 비유전율을 가지는 유전체 매질들이 제안된 안테나와 칩의 연결부 보호를 위해 전체 하우징과 부분 하우징으로 적용되었다. 측정된 반사 손실과 방사 패턴은 계산 결과와 비교하여 잘 일치하였다. 하우징을 하지 않은 제안된 태그 안테나의 인식거리와 3 ㎜ 두께를 가진 실리콘에 의해 전체적으로 하우징된 태그 안테나의 인식거리는 각각 약 5 m와 4 m로 관측되었다. This paper describes a wide bandwidth RFID tag antenna design for protection of connection part between chip and antenna. A proposed tag antenna size, a resonant frequency and bandwidth are 53×10×1 ㎜, 900 ㎒ and 800 ㎒ (500~1,300 ㎒) at ?10 ㏈ below, respectively. The dielectric materials with different relative permittivity such as polyethylene, glass and silicon were applied for protection of connection part between the proposed antenna and chip on the way of whole and partial housing. The measured return loss and radiation pattern agreed well with the calculation results. The read range of the proposed tag antenna without any housing and of tag antenna with housing covered over all by silicon with 3 ㎜ thickness were observed about 5 m and 4 m, respectively.
CMM 급전 구조를 가지는 광대역 다이폴 안테나의 설계
이지철(Ji-Chul Lee),민경식(Kyeong-Sik Min) 한국전자파학회 2010 한국전자파학회논문지 Vol.21 No.9
본 논문은 다이폴 타입 안테나의 광대역화를 위한 원통형 자성 매질 구조를 가지는 급전 프로브의 시뮬레이션 설계를 제안한다. 저주파수 대역의 확보를 위해 고투자율의 자성체를 설계 계산에서 고려하였다. 광대역 특성은 투자율에 의존하지 않고, 자성체와 급전 프로브 사이의 거리(rm)와 자성체의 두께(tm)의 조정에 의해 구할수 있다는 것이 확인되었다. 뿐만 아니라, 원통형 자성 매질의 구조를 가지지 않는 설계 안테나의 크기와 비교하여 약 18 % 정도 소형화시킬 수 있었다. This paper proposes a simulation design for feeding probe with the CMM(Cylindrical Magneto Material) structure for broad bandwidth of a dipole type antenna. In order to ensure low frequency bandwidth, the magnetic material with high relative permeability was considered in design calculation. It was confirmed that the broad bandwidth was independent on the relative permeability value and depended on the control of distance(rm) between magnetic material and feeding probe, and of magnetic material thickness(tm). Furthermore, an antenna size with the CMM was miniaturized about 18 % comparison with its size without the CMM.