http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Two Sensors Method를 이용한 진원도 정밀측정 알고리즘 연구
이응석(Lee Eung Suk),이민기(Lee Min Ki) 대한기계학회 2003 대한기계학회 춘추학술대회 Vol.2003 No.11
This study is for a roundness and runout error algorithm for a DD servo motor and Spindle. Rounness and run out error estimates machine parts. The reason, machine parts have a lot of circular parts, which they have a relationship with DD servo motor and spindle. Especially, runout error is very important. The runout has an effect of machining form and feed. The proposed method is compared with one sensor method and two sensors method. Also, most of roundness is calculated by least square method. To compare result, the one sensor method and the two sensors method is calculated almost identical. To suggest the two sensors method will be used for other geometrical measured data, such as sphere or cylinder for obtaining the exact sphericity or cylindricity.
연구논문 : 생명과학 ; 프로페논 화합물의 배양 대식세포에서 NFκ-B활성화 억제를 통한 NO 및 TNF-α 생성억제
이응석 ( Eung Seok Lee ),주혜경 ( Hye Kyung Ju ),문태철 ( Tae Churl Moon ),이은경 ( Eun Kyung Lee ),장영동 ( Yurng Dong Jahng ),이승호 ( Sung Ho Lee ),손종근 ( Jong Keun Son ),백석환 ( Suk Hwan Baek ),장현욱 ( Hyeun Wook Chang 영남대학교 약품개발연구소 2004 영남대학교 약품개발연구소 연구업적집 Vol.14 No.-
이응석(Eung Suk Lee),이승범(Seung Bum Lee),김기환(Gi Hwan Kim),민들레(Deul Le Min),박종범(Jong Bum Park),박민수(Min Su Park),진이림(E Lim Jin),김태성(Tae Sung Kim) 대한기계학회 2015 大韓機械學會論文集A Vol.39 No.2
대형 5축 문형공작기계는 Gantry가 bed를 따라 절삭, 급송 이송하면서 가공을 수행 한다. 가공을 수행하는 중에 발생하는 오차(Zig-Zag)원인으로써 1) 양쪽 X축 이송모터의 위치오차 제어차이 2) 양쪽 Column의 무게차이에 의해 발생하는 마찰력에 대한 오차 3) spindle 회전력에 따른 오차 3가지의 원인이 있다. 3가지 오차원인을 분석하여 문형공작기계성능을 향상시키기 위해 연구를 진행 하였다. 연구결과로는 첫 번째로 양쪽 Column이 동일한 무게를 갖는 Gantry 구조에서 한쪽 축의 무게를 변경함으로써 마찰력이 미치는 영향을 확인하였다. 두 번째로 우리는 스핀들 회전이 미치는 영향을 해석 및 실험하였다. 그리고 우리는 스핀들 회전이 Gantry이송에 미치는 영향을 확인하였다. A large five-axis gantry-type machine performs cutting operations by moving the gantry, along with a bed. During operation, there are three sources of position (zig-zag) errors: 1) the position difference between two control motors on the X axis, 2) friction difference from the different column weights, and 3) torque of the rotating spindle. This study improved the performance of a gantry-type machine by analyzing these three error sources. We changed the mass of a column in the gantry structure and measured the effect on the friction result. We also studied the spindle torque influences on the movement performance of the gantry in relation to the spindle rotation.
구성주의를 반영한 수학 수업이 학생의 지식 생성 수준 및 추론능력에 미치는 영향 -초등학교 4학년 분수를 중심으로-
이응석 ( Eung Suk Lee ),김진호 ( Jinho Kim ) 한국수학교육학회 2016 初等 數學敎育 Vol.19 No.1
본 연구의 목적은 구성주의를 기반으로 하는 학습자 중심 수학 수업이 학생들의 추론능력과 지식 구성 수준에 미치는 영향을 알아보는데 있다. 이를 위해 초등학교 4학년 분수 단원을 구성주의 수학 수업으로 재구성하여 수업을 실천하고, 학생들의 추론능력과 분수 지식 생성 수준에 미치는 영향을 알아보았다. 분석 결과로부터 다음과 같은 결론을 얻을 수 있었다. 구성주의를 바탕으로 한 학습자 중심 수업은 교사 중심 수업보다 학생들의 추론능력과 학습한 내용에 대한 재생력, 학습하지 않은 지식의 생성력에 긍정적인 영향을 준다. 구성주의를 바탕으로 한 학습자 중심 수업은 교사 중심 수업보다 분수 지식 생성 수준을 향상시키는데 효과가 있다. 구성주의를 바탕으로 한 학습자 중심 수업은 수학적 추론능력을 발달시켜 지식 생성 능력수준을 향상시킨다. 또한, 추론능력과 분수 지식 생성 능력이 학습자 중심 수업을 받은 학생들에게서는 상관이 있었으며 교사 중심 수업을 받은 학생들은 추론능력이 높아도 생성하지 못하는 경우가 많았으나 실험집단은 추론능력이 높으면 지식 생성이 가능하였다. 따라서 학습자 중심수업은 학생들의 추론능력에 긍정적인 영향을 미치며 이를 통해 지식 생성 수준도 향상될 수 있다. The purpose of this research is to find the effects of learner-centered instruction based on constructivism (LCIC) on their knowledge generation level and reasoning ability. To look for them, after fraction units are re-planed for implementing LCIC, instructions using it provide students in a class. From the data, some conclusions can be drawn as follows: LCIC has more positive influence of students on recall ability, generation ability, and reasoning ability than tractional instruction method. With the data it can be said that the interaction exists between learners’ reasoning ability and generation level.
녹내장에서 파장가변 빛간섭단층촬영을 이용한 황반부 신경절세포층의 진단력
이응석(Eung Suk Lee),장지호(Jee Ho Chang),박태관(Tae Kwan Park),온영훈(Young Hoon Ohn),박가희(Ka Hee Park) 대한안과학회 2016 대한안과학회지 Vol.57 No.6
목적: 녹내장 환자에서 파장가변 빛간섭단층촬영(DRI OCT-1, Topcon Co., Tokyo, Japan)을 이용하여 황반부 신경절세포복합체 (macular ganglion cell complex, mGCC)와 황반 신경절세포 및 내망상층(macular ganglion cell inner plexiform layer, mGCIPL)의 두께를 분석해 보고 두 방법의 진단력을 확인해 보고자 한다. 대상과 방법: 2014년 8월부터 2015년 7월까지 본원에 내원한 109명 109안을 대상으로 파장가변 빛간섭단층촬영을 이용하여 mGCC와 mGCIPL의 두께를 측정하여 정상군, 초기, 진행된 녹내장군 간의 차이를 확인해 보고, 각각의 진단력, 민감도, 특이도를 구하여 유두주위 망막신경섬유층(circumpapillary retinal nerve fiber layer, cpRNFL) 두께 분석 방법과 비교해 보았다. 결과: 초기와 진행된 녹내장에 대한 area under the curve를 비교해 보았을 때 mGCC는 0.78과 0.99 cpRNFL과 유의한 차이가 없었으나 mGCIPL은 0.70으로 cpRNFL과 초기 녹내장을 진단하는 경우 cpRNFL의 진단력과 유의한 차이를 나타내었고(p=0.018),녹내장 진단에 대한 민감도와 특이도는 mGCC가 0.95와 0.97, mGCIPL은 0.92와 0.97로 측정되었다. 결론: 두 가지 방법 모두 녹내장을 진단하는 데 있어 높은 민감도와 특이도를 지닌 진단 방법이나, mGCC의 두께 분석 방법이 녹내장의 초기 변화를 감지하는 데 보다 나은 진단력을 가지고 있는 것으로 생각된다. <대한안과학회지 2016;57(6):941-950> Purpose: To evaluate diagnostic ability of macular ganglion cell complex (mGCC), macular ganglion cell inner plexiform layer (mGCIPL) measurements in glaucoma using swept source deep range imaging optical coherence tomography (DRI OCT-1, Topcon Co., Tokyo, Japan). Methods: From August of 2014 to July of 2015, 109 eyes of 109 subjects were assessed for the average thickness and sectional thickness of both mGCC and mGCIPL to determine whether there exists any significant difference among advanced stage glaucoma group, early stage glaucoma group and normal group in Swept source OCT. Comparisons were also made between the above measurements and circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements in their diagnostic accuracy, sensitivity, and specificity. Results: The diagnostic ability of mGCC based-mean thickness value (area under the curve [AUC] = 0.78/ 0.99) in detecting early stage glaucoma group as well as advanced stage group was not significantly different from that of cpRNFL thickness measurement. However, there was a significant difference in thickness between mGCIPL (AUC = 0.70) and cpRNFL in early stage glaucoma groups (p = 0.018). The sensitivities and specificities of mGCC were 0.95/0.97, and those of mGCIPL were 0.92/0.97, respectively. Conclusions: The two swept source OCT based methods measuring retinal ganglion cell layer thickness appeared to have a good diagnostic accuracy, high sensitivity and specificity in detecting glaucomatous eyes. Nevertheless, of the two methods, mGCC thickness measurement was more efficient in detecting early glaucomatous changes. J Korean Ophthalmol Soc 2016;57(6):941-950