http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이원홍,서상신,인경환,이형진,김건중,윤종현,오용호,Lee, W.H.,Suh, S.S.,In, K.H.,Lee, H.J.,Kim, K.C.,Yoon, C.H.,Auh, Y.H. 대한방사선과학회 1999 방사선기술과학 Vol.22 No.1
To inquire its usefulness of the clinical application of intelligent replenishment system of automatic X-ray film processor based on film density, we processed the serial 300 sheets of radiographic film of chest [$14{\times}14"$, HR-C type] and bone [elbow & ankle($8{\times}10"$), skull($10{\times}12"$), hand & foot($11{\times}14"$), pelvis($14{\times}17"$), HR-G type, 68, 70, 77, 85 sheets respectively]. We analyzed the characteristic corves, relative speeds, average gradients and base plus fog densities every twenty five sheets. We also evaluated the developer and fixer replenishment volumes every that time. In the chest and bone radiograph two all, the characteristic curves were little change, and the relative speeds, average gradients and base plus fog densities were within the maximum control limits. The average developer replenishment volumes were about 43m1/sheet and 39m1/sheet respectively. It brings decreased results about 29% in comparison with the conventional replenishment system. In our experiences, we conclude that the intelligent replenishment system of automatic X-ray film processor based on film density maintains image quality consistently, decreases also the replenishment volumes. Therefore, this system will be resulted in economic and environmental effects, and solve problems of over and low replenishment volume.
3차원 고차이론을 이용한 역대칭 앵글-플라이를 갖는 복합재료 적층판의 좌굴 및 진동해석
이원홍,한성천,천경식,장석윤,Lee, Won Hong,Han, Sung Cheon,Chun, Kyoung Sik,Chang, Suk Yoon 한국강구조학회 2003 한국강구조학회 논문집 Vol.15 No.2
To obtain a more accurate response from larninated composite structures, the effect of transverse shear deformation, transverse normal strain/stress, and nonlinear variation of in-plane displacements vis-$\\grave{a}$-vis the thickness coordinate should be considered in the analysis. The improved higher-order theory was used to determine the critical buckling load and natural frequencies of laminated composite structures. Solutions of simply supported laminated composite plates and sandwiches were obtained in closed form using Navier's technique, with the results compared with calculated results using the first order and other higher-order theories. Numerical results were presented for fiber-reinforced laminates, which show the effects of ply orientation, number of layers, side-toithickness ratio, and aspects ratio. 복합재료 적층판의 보다 정확한 해석결과를 얻기 위해서는 종방향 전단변형, 종방향 수직 변형률/응력에 의한 효과와 두께방향좌표에 관한 면내변위의 비선형 변화등이 고려되어야 한다. 본 연구에서는 3차원 고차이론을 이용하여 복합적층판의 좌굴하중 및 고유진동수를 구하였다. 단순지지된 적층판과 샌드위치의 해는 이중삼각함수형태의 Fourier 급수로 변환한 Navier 해법을 사용하였고, 일차전단변형, 고차전단변형이론에 의한 결과와 비교 분석하였다. 본 연구는 매개변수 즉, 보강각도, 적층수와 배열조건, 폭-두께비, 형상비의 변화에 따른 수치 해석 결과를 제시하였다.
Transient Analysis of Partially Supported Laminated Composite Plates With Cutouts
이원홍,한성천,윤석호,Lee, Won Hong,Han, Sung Cheon,Yoon, Seok Ho Korean Society of Steel Construction 1998 한국강구조학회 논문집 Vol.10 No.4
본 연구에서는 부분지지되어 있고 사각형의 개구부를 갖는 적층복합판의 과도해석을 유한요소법을 이용하여 연구하였다. 수학적 지배방정식은 변분과 일차전단변형이론을 고려하여 유도하였고 적층판의 폭-두께비, 재료의 특성, 적층각도, 지지조건이 중앙점의 동적응답에 미치는 영향에 대하여 연구하였다. 수치적인 결과는 그래프와 표로 나타내었으며 참고문헌의 결과와 비교 분석하였다. The transient analysis of partially supported laminated plates with rectangular holes under uniformly distributed transverse load is studied using finite element method. The first-order shear deformation theory and the variational energy method are employed in mathematical formulation. The effects on central deflection by plate thickness ratio, material modulus ratio, ply lamination geometry and boundary conditions are investigated Numerical results are presented and comparisons of the results by the present method with those given in the literature are made.
이원홍,윤석호,한성천,Lee, Won Hong,Yoon, Seok Ho,Han, Seong Cheon 한국강구조학회 1997 한국강구조학회 논문집 Vol.9 No.1
Laminated composite shells exhibit properties comsiderably different from those of the single-layer shell. Thus, to obtain the more accurate solutions to laminated composite shells ptoblems, effects of shear strain should be condidered in analysis of them. A higher-order shear deformation theory requires no shear correction coefficients. This theory is used to determine the buckling loads of elastic shells. The theory accounts for parabolic distribution of the transverse shear through the thickness of the shell and rotary inertia. Exact solutions of simply-supported shells are obtained and the results are compared with the exact solutions of the first-order shear deformation theory, and the classical theory. The present theory predicts the buckling loads more accurately when compared to the first -order and classical theory.
탄성지반위에 놓인 S형상 점진기능재료(FGM)판의 동적 불안정성에 관한 연구
이원홍,한성천,박원태,Lee, Won-Hong,Han, Sung-Cheon,Park, Weon-Tae 한국전산구조공학회 2015 한국전산구조공학회논문집 Vol.28 No.1
This article presents the dynamic instability response of sigmoid functionally graded material plates on elastic foundation using the higher-order shear deformation theory. The higher-order shear deformation theory has ability to capture the quadratic variation of shear strain and consequently shear stress through the plate thickness. The governing equations are then written in the form of Mathieu-Hill equations and then Bolotin's method is employed to determine the instability regions. The boundaries of the instability regions are represented in the dynamic load and excitation frequency plane. The results of dynamic instability analysis of sigmoid functionally graded material plate are presented using the Navier's procedure to illustrate the effect of elastic foundation parameter on dynamic response. The relations between Winkler and Pasternak elastic foundation parameter are discussed by numerical results. Also, the effects of static load factor, power-law index and side-to-thickness ratio on dynamic instability analysis are investigated and discussed. In order to validate the present solutions, the reference solutions are used and discussed. The theoretical development as well as numerical solutions presented herein should serve as reference for the dynamic instability study of S-FGM plates.
지수 및 멱 법칙 점진기능재료 판의 3차원 자유진동해석
이원홍,한성천,안진희,박원태,Lee, Won-Hong,Han, Sung-Cheon,Ahn, Jin-Hee,Park, Weon-Tae 한국전산구조공학회 2015 한국전산구조공학회논문집 Vol.28 No.5
The exponential and power law functionally graded material(FGM) theory is reformulated considering the refined shear and normal deformation theory. This theory has ability to capture the both normal deformation effect and exponential and power law function in terms of the volume fraction of the constituents for material properties through the plate thickness. Navier's method has been used to solve the governing equations for all edges simply supported plates on Pasternak elastic foundation. Numerical solutions of vibration analysis of FGM plates are presented using this theory to illustrate the effects of power law index and 3-D theory of exponential and power law function on natural frequency. The relations between 3-D and 2-D higher-order shear deformation theory are discussed by numerical results. Further, effects of (i) power law index, (ii) side-to-thickness ratio, and (iii) elastic foundation parameter on nondimensional natural frequency are studied. To validate the present solutions, the reference solutions are discussed.
임의의 탄성 경계 지점으로 지지된 판과 쉘의 기하학적 선형 및 비선형해석
이원홍,한성천,박원태,Lee,Won-Hong,Han,Sung-Cheon,Park,Weon-Tae 한국방재학회 2008 한국방재학회논문집 Vol.8 No.3
여러 가지 하중을 받는 임의의 탄성 경계 지지된 판과 쉘의 기하학적 선형 및 비선형해석을 수행하였다. 가정변형률 9절점 쉘 요소를 이용하였으며, 임의의 탄성 경계 지지를 표현하기 위해 6개의 자유도를 갖는 스프링 요소가 사용되었다. 탄성 경계지지 구조물 해석의 응용을 위하여, 여러 형태의 단부 지지를 받는 판과 쉘이 분석되었으며, 이들 단부 지지에 대한 휨 거동을 정확히 얻을 수 있었다. 6개의 스프링으로 표현된 탄성 경계 지지 조건에 대하여 적절한 결과를 얻을 수 있었다. 해석 결과로부터 본 연구의 해석 방법이 임의의 탄성 경계 조건을 갖는 판과 쉘의 거동을 해석하는데 폭넓게 사용될 수 있음을 알 수 있었다. A linear and non-linear analysis for plates and shells with arbitrary edge supports subjected to various loading was presented. The 9-node ANS(Assumed Natural Strain) hell element was employed and the spring element, which could express an arbitrary edge support using the six degrees of freedom, was introduced. For the application of his analysis, the plates and shells with various edge supports were analyzed, and the ending behavior with these edge supports were obtained accurately. For these edge supports, particularly elastic edge support was simulated by six springs and reasonable results were obtained. The results show that the present method can be widely used to analyze the bending behavior of plates and shells with arbitrary edge conditions.
판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 : 판독용 LCD 컬러 모니터 장치의 성능 평가
이원홍(Won-Hong Lee),손순룡(Soon-Yong Son),노성순(Sung-Soon Noh),이인화(In-Hwa Lee),강성호(Sung-Ho Kang),이용문(Yong-Moon Lee),박재수(Jae-Soo Park),윤석환(Seok-Hwan Yoon) 대한방사선과학회(구 대한방사선기술학회) 2008 방사선기술과학 Vol.31 No.1
목 적: 판독용 모니터의 성능을 평가하는데 있어 불필요한 시간 및 인력 등을 줄이고 판독의 최적화 유지와 모니터의 upgrade 시기, 그리고 교체 시기를 결정할 수 있는 시스템을 구축하는데 필요한 적절한 수준의, 일정기간의 성능평가 관리 주기 및 calibration 주기를 결정하고자 하였다. 대상 및 방법: 판독용 LCD 컬러 모니터(CCL350i, Totoku, Japan) 20대를 대상으로 2007년 3월부터 8월(첫 calibration 후 3, 4, 5, 6, 7, 8개월째)까지 매달 1회에 걸쳐 한 달 주기로 총 6회의 성능 평가를 하였다. 성능평가에 사용된 측정 도구는 휘도계(DTP 94 39630, X-Rite Inc. U.S.A.)와 조도계(LX-101 Q031871, Lutron, U.S.A.) 그리고 모니터 성능관리 프로그램인 AAPM TG 18 protocol를 이용하였다. 성능평가 항목은 기하학적 왜곡(geometric distortion), 반사 테스트(reflection test), 휘도 반응 평가(luminance response evaluation), 휘도 균일도(luminance uniformity), 분해능(resolution), 노이즈(noise), 베이링 그레어(veiling glare), 색도(chromaticity) 등 8개 항목을 포함하였다. 결 과: 기하학적 왜곡 평가와 반사 테스트, 휘도 균일도 테스트, 분해능, 노이즈 평가, 베이링 그레어 테스트, 색도 테스트 등은 AAPM TG 18에서 권고하는 기준치에 모두 부합되었다. 휘도반응평가 중 예측되는 최대 휘도와 관측되는 휘도의 편차 항목에서 4개월째부터 25%(4대)의 모니터가 8개월째까지 기준 편차를 벗어나기 시작하였으며, 8개월째에는 다른 모니터 7대에서도 편차를 보이기 시작하여 전체적으로 55%(11대)의 모니터에서 기준 편차를 벗어나고 있었다. 또한 대조도 반응의 편차 항목에서 4개월째부터 예측되는 최대 휘도와 관측되는 휘도의 편차의 기준치를 벗어나기 시작한 4대의 모니터 중 5%(1대)에서 4개월째부터 8개월째까지, 또 다른 2대는 8개월째부터 편차를 보여 전체적으로 8개월째에는 15%(3대)의 모니터에서 기준 편차를 벗어났다. 결 론: 성능평가의 주기는 calibration 후 4개월째부터 오차 범위를 벗어나는 결과와 모니터 수 그리고 성능검사에 소요되는 인력 및 시간을 고려할 때 3개월에 한번씩 평가함이 효율적이라고 판단된다. 또한 calibration 주기는 8개월째부터 50% 이상에서 편차를 보인 결과 및 성능평가 주기를 고려할 때 calibration 후 6개월을 주기로 calibration을 다시 시행하여야 할 것으로 판단된다. Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11(55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.
신장이식예정 환자의 대장조영검사 시 전처치 개선을 통한 재검 감소와 영상의 질 개선
이양섭(Yang Sub Lee),이원홍(Won Hong Lee),이진학(Jin Hak Lee),손은영(Eun Young Son),강성호(Seong Ho Kang),이용문(Yong Moon Lee) 대한영상의학기술학회 2006 대한영상의학기술학회 논문지 Vol.2006 No.1
There are many cases of poor preparation in examining double contrast colon study of recipient a kidney transplant, because the patient with renal failure is limited in intake of water. This study is to improve problems to be caused by poor preparation in examining double contrast colon study of the patient with renal failure by changing the laxative. Of total objective 142 patients with renal failure, 77 patients by Magcorol (250ml) and Dulcorax 2 Tablets and 65 patients by Colonlyte (4ℓ) were examined double contrast colon study. The images were classified into 4 groups including good, common, poor, and fail according to residual feces and mucosal coating by two radiological technologist. Of 77 patients by Magcorol (250ml) and Dulcorax 2 Tablets used for evacuation, Good, common, poor, and fail group were in 11(14.3%), 18(23.4%), 35(45.4%), and 13(16.9%), respectively. Of 65 patients by Colonlyte (4ℓ), Good, common, poor, and fail group were in 10(15.4%), 33(50.8%), 22(33.8%), and 0(0%). In conclusion, to improve a repeat examination and image quality of double contrast colon study of the patient with renal failure, Magcorol (250ml) and Dulcorax 2 Tablets used for the laxative are changed by Colonlyte (4ℓ).
초음파 탐촉자(Probes)의 위생관리 실태와 감염 인식도 조사 및 세균 오염도 측정
김창복(Chang Bok Lee),이양섭(Yang Sub Lee),이원홍(Won Hong Lee),조정찬(Cheong Chan Cho),윤향이(Hyang Yi Yoon),이용문(Yong Moon Lee),김영근(Young Keun Kim),이경섭(Kyung Sup Lee) 대한방사선과학회(구 대한방사선기술학회) 2004 방사선기술과학 Vol.27 No.3
The gel, which is stained on probe after ultrasonogmphy, is a good circumstances for proliferation of microbe. This study is to investigate into the actual state of sanitary management, recognition degree and infection level of ultrasonographic probes. We had performed a question with telephone to 42 hospitals in Seoul area from December in 2003. We also cultured to obtained a sample from three ultrasonographic units to investigate infection level of the probes. Sanita교 management of the probes was performed in 21 hospitals with alcohol cotton, Sanitary management was performed daily in 14 hospitals. Most hospitals used cotton towel for clearing of gel stained on probes. Preventive management against infection was performed in 32 hospitals with vinyl cover, surgical glove, or alcohol sterilization etc. In the recognition degree on infection, the response that using method of ultrasonographic probes is insanitary were in 78.6%(33 hospitals), and 54.8%(23 hospitals) responded that bacteria can be infected through the probes. In the results of germiculture, bacteria and fungi were detected too number of to count, but escherichia coli was not detected. In conclusion, The gel stained on probe after ultrasonography must be cleared completely, and it is necessary that change of reco후ition on sanitary management. 초음파 검사 후 완전히 제거되지 않고 남아있는 Gel은 미생물이 증식하기에 좋은 조건을 가지고 있다. 따라서 본 연구자들은 초음파 탐촉자의 위생관리 실태와 위생과 감염에 대한 인식의 정도를 알아보기 위해서 2003년 12월부터 서울지역에 있는 42개의 병원을 대상으로 전화설문을 시행하였다. 또한 세 대의 초음파 장치 탐촉자에서 시료를 채취하여 미생물을 배양 증식한 후 탐촉자의 오염된 정도를 알아보았다. 21개 병원만이 탐촉자의 위생관리를 실시하였고, 소독 방법은 주로 알콜솜을 많이 이용하였다. 위생관리 주기는 14개 병원만이 매일 하는 것으로 조사되었다. 탐촉자에 묻은 Gel제거 방법은 면수건을 많이 이용 하였다. 감염의 위험에 노출되어 있는 환자의 초음파 검사 시 감염예방관리를 하고 있는 병원은 32개였고 환자 검사 시 탐촉자를 비닐커버나 외과용 장갑, 알콜 소독 후 사용하고 있는 것으로 조사되었다. 감염 인식도 조사에서 초음파 탐촉자 사용법이 비위생적이라는 생각이 78.6%(33개)였고, 탐촉자를 통한 세균이 감염여부에 대해 54,8%(23개)가 감염될 수 있을 것으로 생각하고 있었다. 탐촉자에서 채취한 시료를 배양 한 결과 세균과 진균이 셀 수 없이 너무 많이 오염되어 있었고 대장균은 검출되지 않았다. 결론적으로 초음파 검사 후에는 탐촉자에 묻어있는 Gel에서 세균이 증식하여 감염이 될 수 있으므로 완전히 제거하여 환자간 교차 감염의 위험요인을 줄이는 것과 감염관리에 대한 의식전환이 필요하다고 생각된다.