http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이양진,조리라,Yi Yang-Jin,Cho Lee-Ra 대한치과보철학회 2001 대한치과보철학회지 Vol.39 No.1
Ceromers, new indirect resin system, are now being adopted for esthetic restorations. Despite of its translucency and good color matching, color stability after long-term use was unknown till now. This in vitro study was designed to evaluate color stability of some ceromers when subjected to brushing after thermocycling. Three types of ceromers: Scupture, Targis, Artglass and a direct resin system, Z100 were prepared to disks 12 mm in diameter, 2.5 mm in thickness. All specimens were polished, and Sculpture and Targis specimens were divided two groups, respectively. Then, half of them were glazed according to manufacturer's instructions. All specimen were brushed 20,000 times after 10,000 cycle thermocycling. Color was measured with spectrophotometer after 1,000, 3,000, 10,000 times thermocycling and 20,000 time brushing, respectively. Color difference (${\Delta}E$) was calculated according to CIE LAB system. During thermocycling, Sculpture & Targis system with polished surface showed greater color change than any other groups. After brushing, color difference was reduced significantly. Mean values of ${\Delta}E$ ranged 0.98 to 2.98. All Ceromers were considered clinically acceptable after thermocycling and brushing, and color change mechanism was affected by the brands and finishing methods. It might be concluded that color change of ceromer is due to surface alteration.
만성 상부승모근 통증 환자의 하부승모근에 적용한 테이핑이 상부승모근 긴장도 통증 목뼈 가동성에 미치는 영향
이양진,박동천,김원득,김성열,Lee, Yang-Jin,Park, Dong-Chun,Kim, Won-Deuk,Kim, Sung-Yeol 대한물리치료과학회 2021 대한물리치료과학회지 Vol.28 No.1
Background: The purpose of this study was to investigate the effect of taping applied to the lower trapezius on the upper trapezius muscle tone, pain intensity, cervical rotation range of motion in chronic upper trapezius pain patients. Design: Case-control study. Methods: Twenty subjects with chronic upper trapezius pain were classified into an experimental group and a control group. The experimental group applied lower trapezius facilitation taping and the control group applied sham taping. Taping Before and after the application of taping, muscle tone, pain intensity, and cervical rotation range of motion of the upper trapezius were measured. Results: In the experimental group, there were significant differences in the pressure pain threshold and muscle tone before and after taping. In the comparison between groups, there was a significant difference in muscle tone between the experimental group and the control group. Conclusion: The application of the lower trapezius facilitation taping was found to be effective in reducing the pressure threshold and muscle tone of the upper trapezius. Therefore, it is expected that more effective treatment can be provided by adding lower trapezius facilitation taping to the treatment protocol for patients with chronic shoulder pain.
치밀골 두께 변화에 따른 임플랜트 1차안정성과 즉시하중부담능 평가
이양진,박찬진,조리라,Yi Yang-Jin,Park Chan-Jin,Cho Lee-Ra 대한치과보철학회 2005 대한치과보철학회지 Vol.43 No.2
Statement of problem. Cortical bone plays an important role in the primary implant stability, which is essential to immediate/early loading. However, immediate load-bearing capacity and primary implant stability according to the change of the cortical bone thickness have not been reported. Purpose. The objectives of this study were (1) to measure the immediate load-bearing capacity of implant and primary implant stability according to the change of cortical bone thickness, and (2) to evaluate the correlation between them. Material and methods.48, screw-shaped implants (3.75 mm$\times$7 mm) were placed into bovine rib bone blocks with different upper cortical bone thickness (0-2.5 mm) and resonance frequency (RF) values were measured subsequently. After fastening of healing abutment. implants were subjected to a compressive load until tolerated micromotion threshold known for the osseointegration and load values at threshold were recorded. Thereafter, RF measurement after loading, CT taking and image analysis were performed serially to evaluate the cortical bone quality and quantity. Immediate load-bearing capacity and RF values were analyzed statistically with ANOVA and post-hoc method at 95% confidence level (P<0.05). Regression analysis and correlation test were also performed. Results. Existence and increase of cortical bone thickness increased the immediate load-bearing capacity and RF value (P<0.05) With the result of regression analysis, all parameter's of cortical bone thickness to immediate load-bearing capacity and resonance frequency showed significant positive values (P<0.0001). A significant high correlation was observed between the cortical bone thickness and immediate load-beating capacity (r=0.706, P<0.0001), between the cortical bone thickness and resonance frequency (r=0.753, P<0.0001) and between the immediate load-bearing capacity and resonance frequency (r=0.755, P<0.0001). Conclusion. In summary, cortical bone thickness change affected the immediate load-baring capacity and the RF value. Although RF analysis (RFA) is based on the measurement of implant/bone interfacial stiffness, when the implant is inserted stably, RFA is also considered to reflect implant/bone interfacial strength of immediately after placement from high correlation with the immediate load-baring capacity. RFA and measuring the cortical bone thickness with X-ray before and during surgery could be an effective diagnosis tool for the success of immediate loading of implant.
2-unit cantilever 레진접착성 가공의치 (resin-bonded fixed partial denture) 임상의 현재
이양진,조리라,박찬진,Yi Yang-Jin,Choi Lee-Ra,Parki Chan-Jin 대한치과보철학회 2003 대한치과보철학회지 Vol.41 No.1
Resin-bonded bridge has been an alternative to conventional bridge, since resin-bonded bridge has many attractive advantages such as minimal tooth preparation, short chair time and low cost over conventional bridge. Unfortunately, however, it was reported that resin-bonded bridge showed high failure rate from debonding of retainer in spite of consecutive advances in preparation and materials. And it was shown that multiple abutments were more likely to fail. The majority of debonding failure was considered due to the mobility of the abutment during function. In this view, recently, modification in resin-bonded bridge design was tried. Single retainer, single pontic. 2-unit cantilevered resin-bonded bridge was applied to clinical performance and was shown as retentive or more retentive than fixed-fixed type resin-bonded bridge. This was consistent with the results of studies in 2-unit cantilevered resin-bonded bridges made with all ceramic, In-ceram. The purpose of this article was to overview principles of design and to analyze clinical results of 2-unit cantilevered resin-bonded bridge in comparison with the reports of fixed-fixed resin-bonded bridge.
하악 임플란트 Bicortication 의 응력분산효과에 관한 유한요소분석적 연구
이양진,양재호,이선형,정헌영,Yi, Yang-Jin,Yang, Jae-Ho,Lee, Sun-Hyung,Chung, Hun-Young 대한치과보철학회 1995 대한치과보철학회지 Vol.33 No.3
Dental implantation is a method restoring missing teeth, especially in the case of severely resorbed edentulous patient. But the direct contact between bone and implant surface, induces stress concentration to the bone and eventually becomes a cause. The purpose of this study was to compare the stress distribution patterns between following two cylindrical implant models. One group has implant apex located in the inferior cortical bone and the other in the cancellous bone. Anterior edentulous mandible was modeled with two dimensional 953,878 nodes, 995,918 elements and compared the deflection and stress distribution under the 70 N,4 load cases for 26 models having variant mandibular height and length. The result were as follows; 1. The stress concentration was more affected by the height of the mandible than implant length. 2. Bicortication mitigates the stress of upper cortical and cancellous bone area at the same height of the mandible 3. Perforation of the inferior mandibular cortex significant stress concentration. 4. Stud type porstheses induced less stress concentration to the cortical and cancellous bone than bar type prostheses. 5. Stress of implant apex for stud type was larger than that of bar type.
이양진(Yang-Jin Lee),김재철(Jae-Chul Kim),김용성(Young Sung Kim),조성민(Sung-Min Cho),김광화(Kwang-Hwa Kim) 대한전기학회 2006 대한전기학회 학술대회 논문집 Vol.2006 No.5
변압기 및 GIS 설비 내의 부분방전(Partial Discharging: PD) 발생 시 과도 UHF 신호들이 발생하고 그 신호들은 탱크 안에서 공진한다. 한 개 이상의 PD소스가 존재하고 간섭을포함 할 때, PD에서 발생하는 본 신호들을 정확히 분류 할 수 있는 능력은 진단의 수준을 높일 것이다. 고속 푸리에 변환(FFT)은 주파수변화가 많을 시에, 주요 주파수의 특징 구별이 어렵다. 즉 푸리에 변환 적용 시 noise의 불규칙적인 파형으로 원 신호와의 구분이 어렵다. 그래서 시간과 주파수영역 모두에서 좋은 해상도를 나타내는 웨이블릿을 상요하였다. 변압기 및 GIS 설비 탱크에서 다른 위치의 PD솟로부터 UHF신호들을 인지하는 것에 대하여 웨이블릿에 기초된 방법은, 단지 한 개의 UHF 센서로 신호를 받았을 경우에도 묘사되어진다. UHF PD신호들의 시간-주파수 특성은 웨이블릿 변환으로부터 설립되고, 신호의 에너지 분포 mapping의 의미로 제공되어 진다. 유사함수(similarity function)는 다양한 웨이블릿 계수분포 사이에서 유사성의 측정을 제공하기 위하여 정의된다. 실험으로 측정된 데이터를 통하여 다중부분방전의 유무의 판단하고자 한다.
변압기의 내부 구조 격자화와 신경망을 이용한 부분방전 위치추정 연구
이양진(Yang-Jin Lee),김재철(Jae-Chul Kim),김용성(Young Sung Kim),조성민(Sung-Min Cho) 한국조명·전기설비학회 2006 한국조명·전기설비학회 학술대회논문집 Vol.2006 No.5월
This paper suggests the method for estimating a partial discharge (PD) location using divide of the inside transformer as a grid. The PD location is found swiftly and economically compared with the typical method detecting a PD. The reason is that the location of PD is detected in the section. The estimation of PD location is trained using the Neural Network. JavaNNS(Java Neural Network Simulator) and SNNS(Stuttgart Neural Network Simulator) are used for searching the location of PD. The simulation procedure is following. The transformer is assumed that the case is a regular hexahedron. The sensor is installed in a proper location. A section of PD location is set as a target, and training set is studied with several PD locations in the inside of the transformer. As a result of training process, the learning capability of neural network is excellent. The PD location is detected by division of internal structure of transformer and application of neural network.
초음파 기법을 이용한 변압기내 부분방전 패턴분석에 관한 연구
이양진(Yang-Jin Lee),김재철(Jae-Chul Kim),조성민(Sung-Min Cho),김광화(Kwang-Hwa Kim) 대한전기학회 2006 대한전기학회 학술대회 논문집 Vol.2006 No.11
This paper analyzes partial discharge pattern using Rogowski coil and acoustic emission sensor to power transformer. Therefore, the location of partial discharge and pattern is deduced as obtaining reliable data to establish core structure in transformer.