이성재,송재원,신상영,Lee, Seong-Jae,Song, Jae-Won,Sin, Sang-Yeong 대한전자공학회 1984 전자공학회지 Vol.21 No.3
Submicron gratings are fabricated holographically on thin film single mode and multimode waveguides. Thin film waveguides are made by spin-coating polyurethane solution on the substrates of microscope slide glass and Corning 7059 glass. In order to characterize thin film waveguides, the refract사e index and the thickness of thin films are measured by using the m-line spectroscopy. The fabricated gratings are tested as a grating coupler, a mode converter, and a beam splitter. Also chirped gratings are fabricated to observe beam expansion phenomena and thus the possibility of the wavelength demultiplexing.
이성재,신충훈,최소영,이동형,유순미,송흥권,윤인하,Lee Sung Jae,Shin Chung Hun,Choi So Young,Lee Dong Hyeong,Yoo Soon Mi,Song Heung Gwon,Yoon In Ha 대한방사선치료학회 2022 대한방사선치료학회지 Vol.34 No.-
Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the Halcyon<sup>TM</sup> Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the Truebeam<sup>TM</sup> pelvis mode (Hereinafter referred to as TP), The Halcyon<sup>TM</sup> Pelvis mode (Hereinafter referred to as HP) and The Halcyon<sup>TM</sup> Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, Halcyon<sup>TM</sup> can select more various conditions than Truebeam<sup>TM</sup> in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend Halcyon<sup>TM</sup> Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.