http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
수용성 첨가제를 함유하는 에틸렌초산비닐 메트릭스로부터 5-플루오로우라실의 방출
오승열,유영미,김승수,신병철,육순홍,이해방 한국약제학회 1996 Journal of Pharmaceutical Investigation Vol.26 No.4
In our previous work. we have studied the effect of lactose and sodium alginate (SA) on the rate of release of 5-fluorouracil (5-FU) from ethylene-vinyl acetate (EVA) matrix. These hydrophilic additives promoted the rate of 5-FU release and the increase in rate was larger when SA was used. Both additives showed better ability to increase the rate than 5-FU itself. In this paper, we extended our study to another hydrophilic additive, Carbopol 940 (CP). Compared to SA or lactose, CP increased the rate of 5-FU release markedly. Release rate increased as the loading amount and the pH of the release medium increased. After release experiment, matrix volume increased up to 15 times of that before release experiment. depending on the amount of CP dispersed in the matrix and the pH of the release medium. On the other hand, the volume of the matrix containing lactose or SA decreased, The weight changes of the dry matrix before and after release experiment imply that CP is not released out of the matrix, to the contrary of lactose and SA. Scanning electron microscope study clearly showed that large cavities and pores are generated on the surface and the inside of the matrix. These results indicate that the mechanism by which CP increases the release rate is quite different from that of monomeric additives such as lactose or SA.
오승열,전인영,한기선,강지원,Oh, SeungRyle,Jun, InYoung,Han, KiSun,Kang, JiWon 한국전력공사 2020 KEPCO Journal on electric power and energy Vol.6 No.4
무효전력 보상설비인 분로리액터는 전력계통의 부하 패턴에 따라서 하루에도 수 회 정도 차단기에 의해 운전되거나 정지된다. 분로리액터개폐 시 몇 가지 요인에 의해 발생하는 과전압은 차단기의 절연 성능을 저하시키며, 계통을 구성하는 전력기기에 심각한 전압 스트레스를 유발한다. 분로리액터 개폐 과정에서 발생하는 과도현상을 측정하는 것은 계통을 모의하여 차단기 성능을 검증하는 시험소 수준에서는 가능하나, 실제 계통 운전 중에 발생하는 과도현상을 측정하는 것은 여러 가지 제약으로 어려움이 있다. 따라서 본 논문에서는 실 계통에서 지상 소전류 차단과정에서 가혹한 과도회복전압(TRV: Transient Recovery Voltage)을 유발하는 재발호(reignition)나 전류재단(current chopping) 현상에 대한 해석을 위해 전자계과도해석프로그램(EMTP: Electro-magnetic Transients Program)을 활용한 모델링 과정과 이를 토대로 분로리액터 개폐 과정에서 차단기의 고장을 유발하는 주된 현상에 대해 해석하고자 한다. Shunt reactor, a facility for reactive power compensation, is switched several times a day depending on the load pattern. When the circuitbreaker opens the shunt reactor over-voltage is generated by several factors which degrade the insulating performance of internal parts of the circuit-breaker and cause severe voltage stress on the equipment in the power system. Transient phenomenon occurring during the switching of shunt reactor are available in laboratories that verify the performance of the circuit-breaker by simulating the power system. However, it is difficult to measure the transient phenomenon that occurs during actual operation in actual power system due to many limitations. Therefore, this paper deals with the modeling using EMTP to analyze the reignition and current chopping which causes more severe transient recovery voltage in the small inductive current breaking in actual power systems. In addition, this paper analyzes the main phenomenon that cause circuit-breaker failure in opening shunt reactor using EMTP model.
듀얼 영 벡터 모드를 갖는 2상 RCD-PWM기법에 의한 유도 모터의 스위칭 소음저감
오승열,위석오,정영국 전력전자학회 2004 전력전자학회 논문지 Vol.9 No.6
In this paper, a two-phase DZRCD(Dual Zero Vector Modes RCD) technique is proposed to develope the problem of a conventional two-phase RCD-PWM (Random Centered Distribution PWM) which gives the power spectra of narrow band range in the high modulation index (M). In the proposed DZRCD technique, the zero vector V0 is selected as V0(111) for M 0.8. Also, V0 is selected as V0(000) for the modulation indices < 0.8. For the implementation of the proposed method, a 16-bit micro-controller C167 was used and the experiments were conducted with the 1.5kw induction motor under no load condition. The experimental results show that the voltage / current spectra is spread to a wide band range, and the switching noise of motor is reduced by the proposed method compared to the conventional random operation. 본 연구에서는 높은 변조지수 M 영역에서는 소음 및 고조파 스펙트럼의 광대역화 효과가 저하되는 2상 RCD-PWM(Random Centered Distribution PWM)기법의 문제점을 개선하고자, 듀얼 영 벡터 모드를 갖는 2상 RCD(Dual Zero Vector Modes RCD : DZRCD)기법을 제안하였다. 제안된 2상 DZRCD기법은 변조지수 M=0.8을 기준으로 하여 M이 0.8보다 큰 영역에서는 영 벡터로 V0(111)를 선택하고, 0.8보다 작은 영역에서는 V0(000)를 선택한다. 제안된 방법을 16비트 마이크로 콘트롤러인 C-167기반의 유도 모터 구동 시스템에 적용해 본 결과, M이 0.8이상인 영역에서 모터의 전압 / 전류 및 스위칭 소음 스펙트럼의 광대역화 특성이 종전의 방법과 비하여 우수함을 확인할 수 있었다.
오승열,고현목,권순목,김치하,Oh, Seoung-Youl,Ko, Hyeon-Mok,Kwon, Soon-Mok,Kim, Chee-Ha The Korean Institute of Communications and Informa 2009 韓國通信學會論文誌 Vol.34 No.12b
직교 주파수 분할 다중(OFDM) 기법은 현재 무선 통신에서 가장 중요한 전송 기술 중 하나로 여겨지고 있다. OFDM은 장애가 심한 무선 환경에서 적응 능력이 뛰어나기 때문에 애드 혹(Ad Hoc), 메시(Mesh) 및 센서 네트워크 환경에 이용되기 적합하다. 그러나, OFDM에서 비트 할당과 관련된 기존 연구는 센서 네트워크에서 요구되는 에너지 효율성 및 낮은 계산 복잡도가 충분히 고려되지 않았다. 본 논문은 주파수 선택적 페이딩 채널(Frequency Selective Fading Channel) 환경 하에서 에너지 제한을 고려하며, 낮은 계산 복잡도를 가지는 비트 할당 기법을 제시한다. 이 기법은 피드백 채널을 이용해 수집한 채널 상태 정보를 이용하여 에너지 제한에 맞는 비트 할당 방법을 찾는 적응적(Adaptive) 방법이다. 시뮬레이션을 통하여 성능을 분석한 결과, 본 기법은 매우 낮은 계산 복잡도를 가지지만 계산 복잡도가 높은 최적화 기법과 성능 차이가 거의 없다는 점을 확인하였다. Orthogonal frequency division multiplexing (OFDM) has been investigated as an enabling technology for future wireless communications such as ad hoc, mesh and sensor networks. However, prior works on bit-loading lack consideration of the constraints on energy and computing facility in sensor networks. In this paper, we suggest an adaptive bit allocation algorithm for a frequency selective fading channel environment which exploits channel state information obtained through a feedback channel. The proposed algorithm significantly reduces computational complexity and satisfies the power budget. Also, its throughput is comparable to the optimum solution. Simulation results support the claim stated.