RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재
      • KCI등재
      • KCI등재

        Pontic Design에 따른 임시가공의치의 파절강도에 관한 연구

        오상천,진태호,동진근,Oh Sang-Chun,Jin Tai-Ho,Dong Jin-Keun 대한치과보철학회 1992 대한치과보철학회지 Vol.30 No.1

        The purpose of this study was to evaluate the flexure stregth of posterior 4-unit acrylic resin bridge with different pontic designs : 1) Conventional pontic 2) Hygienic pontic and 3) Modified hygienic pontic. All specimens were made of self-curing acrylic resin for provisional restorations. Self-curing acrylic resin was filled in a silicone mold by the drop-on technique ; and was polymerized in a pressure spot under 20 psi pressure. The test specimens which were simply shaped posterior 4-unit bridge were 38mm ion 4mm wide, and 35mm thick(connector : 3mm thick). Each specimen was subjected to an increasing load of Instron machine with its tip centered on the specimen at 90-degree angle, and the machine was operated with its load cell of 50kg and its crosshead speed, 2mm/minute : and then the load values at the moment of the fracture of them were recorded. This study was also performed to analyze their stress distributions by the finite element method. The obtained results were as follows : 1. Flexure strength of the hygienic pontic(9.78kg) and the modified hygienic pontic(10.17kg) was higher than that of conventional pontic(6.96kg). But no significant difference was found between the hygienci pontic and the. modified hygienic pontic. The above statistic values were appraised by ANOVA and Duncan's multiple range test 2. Stress was concentrated on the middle portion in every group : and the stress of conventional pontic was found the greatest of all pontic designs.

      • KCI등재
      • KCI등재

        한국 성인의 하악대구치 임상치관의 형태와 크기에 관한 연구

        오상천,Oh, Sang-Chun 대한치과보철학회 1999 대한치과보철학회지 Vol.37 No.2

        The purpose of this study was to estimate the morphology and the size of permanent mandibular molar in Korean Adult. The 100 dental college students with a normal dentition and without any dental prosthesis and severe caries were selected for this study The subjects were taken impression to make study model. On the study model, the 5 dentists measured those sizes and estimated morphological structures with a calipers, a Boley gauge and a protractor. The results were as follows; 1. The clinical crown height, width, thickness and the other anatomical structures had symmetrical relationship between the left and right mandibular molar. 2. In the clinical crown height aspect, the buccal crown heights always were higher than the lingual crown height. The heights of the each surface, the buccal or lingual surface, were gradually decreased from the 1st molar to the 2nd molar and the difference on the buccal surface was higher than that on the lingual surface. 3. In the clinical crown width aspect, the mesiodistal measurement of the mandibular 1st molar was higher than that of the mandibular 2st molar. 4. In the clinical crown thickness aspect, the mesial buccolingual measurement was highest on the mandibular 1st molar and the distal buccolingual distance was lowest on the mandibular 2nd molar. This distal thickness of the mandibular molar always was higher than that of the mesial half. 5. The well-developed mesiobuccal groove of the 1st molar was observed more often than that of the 2nd molar. The buccal pit was also observed more frequently at the 1st molar, but the frequency(35%) was not high. 6. The occlusal type according to the number of cusp was almost 5-cusp(98%) in the 1st molar and was also 5-cusp(63%) in the 2nd molar. The frequency of the 6th cusp was 31% in the 1st molar and was 22% in the 2nd molar. The frequency of the 7th cusp was below 2of in the both teeth. 7. In the buccolingual intercuspal distance aspect of the mesial and distal half, the intercuspal distance of distal half was higher than that of the mesial half on the 1st and 2nd molar, but the difference on the 1st molar was higher than that on the 2nd molar. 8. The difference between the widths of the buccal and lingual half was 1.5mm in the 1st molar and 0.8mm in the 2nd molar. Therefore the lingual convergency of the occlusal surface was more higher in the 1st molar. 9. On the mandibular 1st and 2nd molar, the distobuccal external angle was more acute than the mesiobuccal external angle. But the mesiobuccal internal angle was more acute than the distobuccal internal angle. 10. When the mandibular molar was a 5-cusp type, the development of the distal cusp on the 1st molar was better than that on the 2nd molar. The difference between the cusps was around 0.4mm.

      • KCI등재

        Combined application of roll flap and combination onlayinterpositional graft to enhance esthetics of maxillary anterior fixed partial denture: A case report

        오상천,차동희,이재인 대한치과보철학회 2016 The Journal of Advanced Prosthodontics Vol.8 No.1

        In the maxillary anterior region, reconstruction of the localized alveolar ridge defect is very important in enhancing the esthetics of fixed partial denture. A 40-year-old female patient presented with a chief complaint of the inconvenience and unesthetic problem of 3-unit maxillary anterior prosthesis due to alveolar ridge resorption. After removal of old prosthesis, intraoral examination revealed moderate (buccolingually 4 mm) ridge deficiency in missing tooth region, leading to the diagnosis of Class I alveolar ridge defect. One of the reconstruction techniques to overcome this problem might be a technique that combines two types of soft tissue augmentation techniques. The purpose of this paper was to demonstrate the new combined technique of roll flap and combination onlay-interpositional graft utilized to acquire sufficient dimension of recipient area by one time of operation and to present the esthetic improvement of fixed partial denture by using this procedure in case of maxillary anterior localized ridge defect.

      • KCI등재

        주입선 설계에 따른 Heat-pressed ceramic의 파절강도에 관한 연구

        오상천,동진근,Oh, Sang-Chun,Dong, Jin-Keun 대한치과보철학회 1997 대한치과보철학회지 Vol.35 No.1

        A heat-pressed technique(IPS-Empress, Ivoclar) has been described to construct single unit crown, inlay/onlay and veneers using a partially pre-cerammed and pre-colored glass-leucite ingot that has the greateast strength by the combination of heat-pressed procedure through the smalldiameter sprue and heat treatment procedure. The purpose of this study was to evaluate the flexure strength of a heat-pressed ceramic material(IPS-Empress) without simulated firing treatments according to pontic designs. Two groups of 9 disks(1.4mm thick, 14mm in diameter) each using two types of sprues with different diameters($({\Phi}2.8\;,{\Phi}1.8)$) and numbers were prepared. The specimens were mounted in the testing jig. The flexural strengths were determined, by means of the bi-axial bending test, by loading the center of disk to failure using a universal testing machine(Zwick 145141, Zwick, Germany) at a cross-head speed of 1.0 mm/min. The means flexural strength value of one group using a sprue with ${\Phi}2.8$ was $140.4{\pm}8.0Mpa$. That of the other group using two sprues with ${\Phi}1.8$ was $151.8{\pm}10.3Mpa$. After analysis, results showed that there was a statistical difference between groups(t=2.33m p<0.05). No clnical implications were drawn from these data because of absence of simulated firing treatment.

      • KCI등재
      • KCI등재
      • PONTIC DESIGN에 따른 임시가공의치의 파절강도에 관한 연구

        오상천,진태호,동진근 원광대학교 치의학연구소 1992 圓光齒醫學 Vol.2 No.1

        The purpose of this study was to elvaluate the flexure stregth of posterior 4-unit acrylic resin bridge with different pontic designs : 1)Conventional pontic, 2)Hygienic pontic, and 3)Modified hygienic pontic. All specimens were made of self-curing acrylic resin for provisional restorations. Self-curing acrylic resin was filled in a silecone mold by the drop-on technique ; and was polymerized in a pressure spot under 20 psi pressure. The test specimens which were simply shaped posterior 4-unit bridge were 38 ㎜ long, Um wide, and 8.5㎜ thick (connector : 3㎜ thick). Each specimen was subjected to an increasing load of Instron machine with its tip centered on the specimen at 90-degree angle, and the machine was operated with its load cell of 50㎏ and its crosshead speed, 2㎜/minute : and then the load values at the moment of the fracture of them were recorded. This study was also performed to analyze their stress distributions by the finite element method. The obtained results were as follows 1) Flexure strength of the hygienic pontic (9.78㎏) and the modified hygienic pontic (10.17㎏) was higher than that of conventional pontic (6.96㎏). But no significant difference was found between the hygienic pontic and the modified hygienic pontic. The above statistic values were appraised by ANOVA and Duncan's multiple range test. 2) Stress was concentrated on the middle portion in every group : and the stress of conventional pontic was found the greatest of all pontic designs.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼