Steam soot-blower control valves for thermal power plants operate in a uniquely severe service and environment. They must not only frequently modulate flow over a wide range but must also maintain downstream pressure between very close limits at high differential. In addition, they also must function as block valves with tight shutoff every time they close to prevent soot-blower header pressure safety relief valve operation due to system overpressure. Satisfactory operation in these two separate functions is a problem often found in the power industry. Because of poor valve operating experience the soot-blower control valves were recently replaced with valves specifically designed for soot-blower service.