송길목(Shong, Kil-Mok),정호성(Jung, Ho-Sung),권창오(Kwon, Chang-Oh) 대한전기학회 2022 전기의 세계 Vol.71 No.11
전기설비 측면의 탄소중립 감축을 위하여 Energy shift 와 Modal shift 와 같은 전략적인 추진방법이 필요하다. 전기설비 생애주기의 전 과정에 있어서, 전기안전 분야에서의 유지 · 관리를 통한 전기설비 효율 증가, 전기재해 예방, 주요전력설비 배출계수 관리 방안 / 전기철도 기반 전기수송 분야에서의 Modal shift를 통한 친환경 수송자원으로의 변환 방안 / 설비시공 분야에서의 전환과정 진행상황 관리를 통한 목표달성 상태 확인 방안을 추진전략으로 제시하였다.
송길목(Kil-Mok Shong),김영석(Young-Seok Kim),정진수(Jin-Soo Jung) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.7
It's described the discharge characteristics and ICP-AES analysis of insulators by surface deterioration in this paper. For the assessment of insulators, there are applied the conductivity of dusts, contact angle measurement of the insulator surfaces and the ingredient analysis in each area. Through the analysis of pollutants attached to insulators inside the tunnel, the cleaning cycle is discussed. As the results, it would be expected to the electrical safety.
송길목,최충석,노영수,곽희로 대한전기학회 2004 전기학회논문지C Vol.53 No.1(C)
This paper describes the carbonization characteristics of a phenolic resin deteriorated by tracking under the environment of a fire. In the experiment, a liquids droplet of 1[%] NaCl was dripped on the phenolic resin to cause a tracking with 110[V], 220[V] voltages applied. It can be addressed from the experimental results that when an insulator is carbonized by an external fire, its structure is amorphous. If an insulator is carbonized by electrical cause, on the other hand, its structure would be crystalline. In order to observe the surface change of the phenolic resin, the tracking process was analyzed by using SEM. In the case that the materials are carbonized under heat or fire, the exothermic peak appears around 500[℃]. This is one of the important factors to determine the cause of fires. As a result of DTA, the exothermic peaks of an untreated sample showed at 333.4[℃], 495.7[℃] but those of a sample deteriorated by tracking appeared at 430.6[℃], 457.6[℃] in a voltage of 110[V], and at 456.2[℃], 619.7[℃] in a voltage of 220[V]. It is possible, therefore, to distinguish a virgin sample from carbonized samples(graphite) by the exothermic peak.
22.9 kV 폐쇄 배전반내의 사고모델을 통한 실험검증 및 개선
송길목,최충석,한운기 대한전기학회 2006 전기학회논문지 P Vol.55 No.2
This paper describes the accident analysis by modelling the current transformer mounting in a metal-clad switchgear at 22.9kV. In analyzing the accident, the reconstruction at the current transformer mounting(VCB connecting guide) has to be taken into account. The accident was modelled as a 3-phase ground fault occurring between the end plate of 22.9kV lines and the safety shutter at the current transformer mounting of the VCB inside the metal clad switchgear. Since the outside maintenance of the metal clad switchgear is restricted by the enclosed compartments, its circumference has to be kept clean. Through the reconstruction results, it was confirmed that the fault of the enclosed switchboard could be reduced when the shutter made of Fe material was changed into an insulation.