http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
서재호 圓光大學校 1990 論文集 Vol.24 No.2
In this paper, a new method of reducing harmonics that involved input ac line currents on it output dc voltage of the converter system is presented, which is due mainly to the equipment of 2-5 switching taps on interphase reactor. Therefore, the originality of this paper lies in microprocessor based equipment of the 2-5 switching taps on interphase reactor. I applied this method to the 12 pulse converter, and proved validity of that theoretically and experimentally. I propose a furthermore improved method, in which I employ an switching taps circuit constructed with only thyristors in the circuit of interphase reactor. Therefore, main contents of this study are the following two items; 1) Optimum value of turn ratio of interphase reactor. 2) Optimum value of control angle of switching taps. However, in case that the 5tap method is applicable to above optimum conditions, it could not bring to an effect of reducing hamonics under firing angle 15。. At present I can conclude that the converter must be constructed switching taps circuit and must be controlled 2-5 tap changing method.
지방자치제 실시와 지방자치단체 복지행정기구의 변화에 대한 연구: 기초자치단체를 중심으로
서재호 한국행정학회 2008 韓國行政學報 Vol.42 No.2
본 연구는 시・군・자치구 및 전체 기초자치단체로 유형을 나누어 지방자치단체의 복지행정기구 변화에 대한 지방자치제 실시효과를 분석하고 있다. 특히 본 연구는 지방자치제 실시 이후 1기 자치정부 → 2기 정부 → 3기정부로 지방자치제도의 전개에 따른 지방정부 복지행정기구의 변화에 대한 분석도 실시하였 다. 분석을 위하여 1992년부터 2005년까지 159개 기초자치단체의 패널자료를 구성하여 복지행정담당 (계)의 수와 복지행정담당(계)이 전체 행정기구담당(계)에서 차지하는 비율의 변화추이를 분석하였다. 분석결과 통계적으로 유의미한 결과를 보고하지 않은 자치구와 군유형의 기초자치단체를 제외하고, 전 유형의 기초자치단체에서 지방자치제 실시에 따라 지방자치단체 행정조직의 복지행정기능이 강화된 것 으로 나타났다. 또한 1기자치정부에서 3기자치정부로 나아갈수록 복지행정기능의 강화경향은 점증하는 것으로 나타났다. 이 같은 결과는 우리나라에 도입된 지방자치제가 지방행정조직차원의 자율성을 어느 정도 확보해 주고 있으며, 지방자치제를 경험할수록 지역주민의 복지수요가 행정기구의 변화에 비교적 잘 반영되고 있음을 시사해 주는 것이다. This study examines the effects of implementation of local autonomy on the change of welfare related organizational units in local government. For the empirical test, this study uses 1750 panel data from 1992 to 2005 for 157 local governments and uses welfare related organizational units and a ratio of the units. Results show that the effects of implementation of local government on the change of welfare related organizational units is positive in most types of local government and the regression coefficients of dummy variables of first, second, and third governments increased. This implies that the implementation of local autonomy guarantee local autonomy from the upper government organization and the welfare needs of local people are reflected in the organizational change of local government.
『Microprocessor를 利用한 電動機의 PLL 速度制御系와 特性解析』
徐在鎬 圓光大學校 1985 論文集 Vol.19 No.2
This paper presents a microprocessor-based digital PLL speed control system and describes several methods to analysis the system performance. In this system digital techniques provide all the control functions such as detection of speed and phase error of the ortor, signal processing and the determination of the control signal of the power converter. They can be achieved with a simple circuit architecture by using a microprocessor. The completely digital scheme is free from drift and off-set error which are inherent in an analog circuit. Sampling, time delay and quantization of phase sroor detection effect respectively the stability, dynamics and speed error of the system. For the analysis of system performance, the digital simulation based on the state-space method is used. The stability, dynamics and speed error of system are additionally analyzed with the simplified models. An experimental apparatus including a 2.2KW DC motor is built and the system is tested. The experimental results confirm the validity of the analytical methods mentioned above.
마이크로프로셰서를 이용한 디지탈 PLL시스템에 의한 3상 유도전동기의 속도제어에 관한 연구
徐在鎬 圓光大學校 1987 論文集 Vol.21 No.2
이 논문은 Phase-Locked Loop (PLL) 속도제어계의 계통구성에 의한 위상차검출기를 제작하여 Phase Frequency Detector (PFD)에 의한 오차전압은 Analog Switch 에 의해 정확한 속도 위상차 만을 Microprocessor에 전달하도록 하고, digital controller의 Hard ware를 구성하여 digital filter를 설계하였으며 Analog 제어기법인 PLL의 filter에서의 정상오차를 digital기법에 의해 drift가 없고 주파수 응답특성이 이상적이 될 수 있도록 시스템을 완성 제작하였다. 또한 이 시스템을 이용한 실험을 행하여 고정도(高精度)의 3 상농형 유도전동기 속도제어가 가능하다는 결론을 얻었다. This paper presents a microprocessor-based digital PLL speed control system. In this system digital techniques provide all the funtions such as detection of speed and phase error of the rotor. The Completely digital scheme is free from drift and off-set error which are inherent in an analog circuit, Digital filter using microprocessor are employed. An experimental apparatus including a 0.5 ?? 2 Pole 3 Phase induction motor is concluded that the PLL system of digital fillter using microprocessor is a system with excellent speed regulation.
Thyristor Bridge에 의한 單相 力率 調整에 關한 硏究
徐在鎬 大田工業專門學校 1977 論文集 Vol.21 No.-
This paper treated a method of power factor adjustment using a single phase thyristor bridge. Sufficiently large Reactor is connected to the cutput of the bridge and a method is presented to change the power factor of the input of a bridge by varying the controll angle α and β. The above mentioned theory ver??ed through experiment.