RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        스펙트럼영역 빛간섭단층촬영 유의지도에서 자동으로 구한 국소적 망막신경섬유층결손면적

        서샘,신중원,엄기방,Sam Seo,MD,Joong Won Shin,MD,Ki Bang Uhm,MD,PhD 대한안과학회 2013 대한안과학회지 Vol.54 No.6

        Purpose: To evaluate the usefulness of automated measurements of the localized retinal nerve fiber layer (RNFL) defects area in patients with glaucoma. Methods: Fifty one patients with localized RNFL defects in RNFL red-free photographs and 53 healthy subjects were included. All participants were imaged with 3D spectral-domain optical coherence tomography (OCT). The area of defects was measured with the RNFL significance map (red = p < 1% and yellow = p < 5%) using Image J manually and Matlab software automatically. The area under the receiver operating characteristic curve (AUC) was calculated for the RNFL defect area of the RNFL photograph and RNFL maps, circumpapillary RNFL thickness, optic disc parameter, and macular inner retina thickness. Results: High correlation was observed between manually and automatically measured defect areas in the significance map (red area r = 0.904, red and yellow area r = 0.890). The AUC for manually and automatically measured defects area (0.987, 0.966; p < 5%, p = 0.31, respectively) in the significance map was comparable. The latter demonstrated slightly higher but insignificant difference in AUC for inferior quadrant circumpapillary RNFL thickness (0.936; p = 0.22) and was significantly higher than the inferior ganglion cell layer plus inner plexiform layer thickness (0.894) and vertical cup to disc ratio (0.869) (p = 0.018, p = 0.008, respectively). Conclusions: The automated measurements of the RNFL defect area in the significance map performed adequately in detecting localized RNFL defects and had a better performance than macular inner retina and optic nerve parameters.

      • KCI등재

        특발성 망막전막에서 유리체절제술 전후 미세시야계를 이용한 구조와 기능의 상관관계 분석

        서샘,임한웅,신용운,강민호,성민철,조희윤.Sam Seo. MD. Han Woong Lim. MD. Yong Un Shin. MD. Min Ho Kang. MD.Min Cheol Seong. MD. Hee Yoon Cho. MD 대한안과학회 2013 대한안과학회지 Vol.54 No.6

        Purpose: To investigate the relationship between photoreceptor inner/outer segment (IS/OS) integrity and macular sensitivity after epiretinal membrane (ERM) surgery using spectral-domain optical coherence tomography combined with microperimetry. Methods: 20 eyes of 20 patients with idiopathic ERM who underwent pars plana vitrectomy for ERM removal were prospectively reviewed. The IS/OS defect diameter, BCVA, macular sensitivity, and fixation stability were measured using spectral-domain optical coherence tomography combined with microperimetry. The correlation of these factors was analyzed. Results: The macular sensitivity improved after successful ERM surgery (p < 0.001), but the IS/OS defect diameter has not improved. The preoperative and postoperative macular sensitivity were negatively correlated with preoperative IS/OS defect diameter (p = 0.035, p = 0.006). The fixation stability was not correlated with preoperative IS/OS defect diameter. Conclusions: Macular sensitivity showed significant correlation with IS/OS defect diameter. Macular sensitivity is vital functional parameter allows subjective quantification of the retinal function and reflects morphologic changes.

      • KCI등재

        유리체절제술과 백내장병합수술 후 앞방 깊이와 안구 길이 및 굴절력의 변화 측정

        서샘,성민철,임한웅,강민호,조희윤,Sam Seo,MD,Min Cheol Seong,MD,Han Woong Lim,MD,Min Ho Kang,MD,Hee Yoon Cho,MD 대한안과학회 2013 대한안과학회지 Vol.54 No.7

        Purpose: To evaluate the changes of anterior chamber depth (ACD), Axial length (AXL) after combined vitrectomy and cataract surgery and to analyze the association with refractive errors. Methods: In 22 eyes who underwent combined vitrectomy and cataract surgery (PPV-Phaco group), 20 eyes who underwent vitrectomy-only (PPV-only group) and 28 eyes who underwent uncomplicated cataract surgery (Phaco-only group), ACD and AXL were measured with IOL master (Carl Zeiss Jena, Germany) preoperatively and 3 months postoperatively. We compared the preoperative desired refraction and postoperative 3 months refraction. Results: ACD were increased in PPV-Phaco group and Phaco-only group (all, p < 0.001) and this change was more prominent in PPV-Phaco group (p = 0.030). In PPV only group, ACD was decreased (p < 0.001). The AXL after surgery was not significant different from the preoperative AXL in PPV-Phaco and PPV only groups (p = 0.612, p = 0.090). But the AXL was decreased in Phaco-only group (p = 0.022). Hyperopic shifting were noticed in PPV-Phaco and phaco-only groups, but myopic shifting was noticed in PPV-only group. However, these changes were not statistically significant (p = 0.292, p = 0.251, p = 0.068). Conclusions: ACD was increased after combined vitrectomy and cataract surgery. AXL was not changed. The hyperopic shifting was noticed after combined vitrectomy and cataract surgery, but was not statistically significant.

      • KCI등재

        점안약 차트를 통한 녹내장 환자의 점안약 사용법 및 순응도 향상

        심규영,서샘,이수진,이종은 대한안과학회 2019 대한안과학회지 Vol.60 No.2

        Purpose: To evaluate the efficacy of an eye drop chart and to determine the factors contributing to adherence enhancement using the eye drop chart. Methods: In this prospective study, enrolled glaucoma patients were educated on the administration of eye drops and use of the eye drop chart. They were required to complete a questionnaire on demographic characteristics and adherence. After 3 months, they completed a second questionnaire on adherence and satisfaction with the use of the eye drop chart. Changes in instillation behavior, relationships between performance scores and demographic characteristics, as well as factors contributing to the improvement of performance scores were analyzed. Results: Forty-seven patients were enrolled in this study. The performance scores were significantly better for those who administered the eye drops by themselves (p = 0.002), those with an annual income > 60 million won (p = 0.036), and patients with at least a college degree (p = 0.002). After using the eye drop chart for 3 months, the average intraocular pressure was significantly reduced (p = 0.041) and the performance score was improved (p = 0.019). The working area (p = 0.009) and eye drop applicator (p = 0.001) were correlated with performance score enhancement. Conclusions: The eye drop chart was a cost-effective tool for improving the adherence and instillation practices of glaucoma patients. Adherence was improved among patients with more indoor activity, and those who practiced self-instillation. It is expected that the respective conditions of such patients would be more efficiently improved in a clinical setting. 목적: 녹내장 안약을 점안하는 환자들을 대상으로 점안약 차트를 통한 순응도 향상을 알아보고자 한다. 대상과 방법: 녹내장 점안약을 사용 중인 환자를 대상으로 점안약 차트를 통해 점안 방법을 교육하였으며, 점안약 차트 사용 전과 사용 3개월 후 설문조사를 시행하여 녹내장 안약 점안의 수행성적(performance score)을 조사하였다. 점안약 차트 교육 전후 수행성적의 변화를 분석하고 사전조사 항목들과 검사 결과들의 수행성적과의 연관성을 분석하였다. 또한 수행성적에 따라 두 군으로 나누어 사전설문조사와 안약점안 방법 등의 수행성적 향상에 영향을 미치는 인자를 분석하였다. 결과: 47명의 환자가 연구대상자로 등록되었다. 점안약 차트 사용 전에는 안약점안 주체(p=0.002), 연평균 소득(p=0.036), 교육수준 (p=0.002)에 따라 수행성적의 유의한 차이를 보였다. 3개월간 점안약 차트 사용 후 평균 안압은 통계학적으로 유의미하게 감소하였고 (p=0.041), 수행성적의 향상도 이루어졌다(p=0.019). 다변수분석에서 활동영역(p=0.009), 안약점안 주체(p=0.001)가 수행성적의 향상에 유의한 상관관계를 보였다. 결론: 녹내장 환자에게서 점안약 차트 사용은 안압을 하강시킬 수 있는 효과적인 보조 방법이며, 안약 사용법을 환기시켜 순응도를 향상시키는 효과가 있다. 특히 본인이 직접 안약을 점안하는 환자, 주로 실내에서 활동하는 환자에서 순응도 향상에 효과적이었다.

      • KCI등재

        개방각녹내장에서 라타노프로스틴부노드 0.024%의 단기적 효과, 안정성 및 안구 혈류 변화

        김현우,이종은,서샘,이규원,이창훈 대한안과학회 2023 대한안과학회지 Vol.64 No.10

        목적: 라타노프로스트 0.005% 대비 라타노프로스틴부노드 0.024%의 안압하강, 안구 혈류 개선 효과를 알아보고자 한다. 대상과 방법: 2022년 5월부터 12월까지 라타노프로스트 0.005%를 점안 중인 개방각녹내장 환자 40명을 대상으로 라타노프로스틴부노드 0.024%로 교체하였다. 교체 후 3개월까지 안압, 시력, 시신경유두 주위 혈관밀도, 결막충혈, 각막미란, 눈 주위 색소 침착 및주관적 부작용을 비교하였다. 결과: 라타노프로스틴부노드 0.024% 교체 전과 후 3개월까지 안압은 17.53 ± 6.49 mmHg에서 16.00 ± 8.06 mmHg로 유의하게감소하였다(p=0.032). 최대교정시력은 교체 전과 후 3개월까지 0.24 ± 0.19에서 0.23 ± 0.16으로 유의한 변화가 없었다(p=0.343). 눈 주위 색소 침착은 교체 전과 후 3개월까지 1.16 ± 0.78에서 1.16 ± 0.82로, 점상각막미란은 교체 전과 후 3개월까지 0.58 ± 0.85에서 0.39 ± 0.76으로 유의한 변화가 없었다(각 p=1.000, p=0.050). 결막충혈은 교체 전과 후 3개월까지 1.77 ± 0.88에서 1.42 ± 0.81로 유의하게 감소하였다(p=0.010). Whole image vessel density, peripapillary vessel density는 유의한 변화가 없었다(p>0.05). 부작용은 교체 후 3개월까지 가려움만 유의하게 증가하였다(p=0.008). 결론: 라타노프로스틴부노드 0.024%는 우수한 단기적 안압하강 효과를 보였으나 안구 혈류의 유의한 개선은 없었다. Purpose: To study the short-term intraocular pressure (IOP)-lowering effect and optic nerve head (ONH) blood flow improvement after switching from latanoprost 0.005% w/v to latanoprostene bunod 0.024% w/v. Methods: This prospective study ran from May 2022 to December 2022 and included 40 patients with open-angle glaucoma who switched from latanoprost 0.005% w/v to latanoprostene bunod 0.024% w/v. The IOP, ONH blood flow, and conjunctival hyperemia, corneal erosion, and eyelid pigmentation status were measured 3 months after switching. We recorded all possible side effects. Results: The baseline IOP significantly dropped from 17.53 ± 6.49 to 16.00 ± 8.06 mmHg at 3 months (p = 0.032). The best-corrected visual acuity did not significantly change (0.24 ± 0.19 to 0.23 ± 0.16); neither did eyelid pigmentation (1.16 ± 0.78 to 1.16 ± 0.82) nor the corneal erosion score (0.58 ± 0.85 to 0.39 ± 0.76). Conjunctival hyperemia significantly decreased from 2.00 ± 0.69 to 1.67 ± 0.63 (p = 0.010). Neither the whole-image vessel density nor the peripapillary vessel density significantly changed. However, pruritus became significantly worse after the change (p = 0.008). Conclusions: In the short term, latanoprostene bunod 0.024% w/v lowered the IOP more effectively than did latanoprost 0.005% w/v. However, there was no significant change in ONH blood flow after the switch.

      • KCI등재

        단안 선택적 레이저섬유주성형술에서 안압 변동을 보정한 성공예측인자의 분석

        이준석,이종은,서샘,이규원 대한안과학회 2018 대한안과학회지 Vol.59 No.12

        Purpose: To investigate the efficacy, and identify predictors of success of selective laser trabeculoplasty (SLT) in open-angle glaucoma (OAG) patients after adjusting for intraocular pressure (IOP) changes in the untreated fellow eye. Methods: This retrospective chart review included 52 eyes of 52 OAG patients who underwent SLT in one eye and were followed- up for at least 1 year after the procedure. The IOP was measured before the treatment, at 1, 2, and 3 months posttreatment, and every 3 months thereafter. To account for the possible influence of IOP fluctuations on laser outcomes, post-laser IOP values of the treated eye of each patient were also analyzed, after adjusting for IOP changes in the untreated fellow eye. Success was defined as an IOP decrease ≥20% of the pretreatment IOP. The success rate was determined based on Kaplan-Meier survival analysis and factors predictive of success were analyzed using the Cox proportional hazard model. Results: The mean pretreatment IOP was 23.17 ± 6.96 mmHg. The mean IOP reduction was 5.59 ± 4.78 mmHg (29.7%) and the success rate was 65.4% at 1 year. The adjusted mean IOP reduction was 4.70 ± 4.67 mmHg (23.9%) and the adjusted success rate was 53.9%. Pretreatment IOP was associated with SLT success; the higher the pretreatment IOP, the greater the post-laser IOP reduction (p = 0.025). Age and mean deviation index did not show a significant association with SLT success (p = 0.066 and p = 0.464, respectively). Conclusions: SLT is a safe and effective alternative method of IOP reduction in OAG patients. Herein, pretreatment IOP was the only factor significantly associated with SLT success. IOP fluctuations of the untreated eye should be considered for a better understanding of the impact of treatment. 목적: 선택적 레이저섬유주성형술(selective laser trabeculoplaty, SLT)을 시행 받은 개방각녹내장 환자에서 치료받지 않은 반대안의 안압을 보정하여 SLT의 안압하강 효과 및 성공예측인자를 분석하고자 하였다. 대상과 방법: 단안에 SLT를 시행 받고 1년 이상 관찰한 개방각녹내장 환자 52명 52안을 후향적으로 분석하였다. 시술 전, 시술 후 1, 2, 3개월, 이후 3개월마다 안압을 측정하였다. 시술 후 안압은 치료받지 않은 반대안의 안압변화량으로 보정하여 계산하였다. SLT의 성공은 시술 전 안압보다 20% 이상 감소한 경우로 정의하였다. Kaplan-Meier 생존분석을 이용하여 성공률을 산출하였고, 성공예측인자를 분석하였다. 결과: 시술 전 평균 안압은 23.17 ± 6.96 mmHg, 시술 후 1년째 평균 안압하강은 5.59 ± 4.78 mmHg (29.7%)였으며, 반대안 안압을 보정한 안압하강은 4.70 ± 4.67 mmHg (23.9%)였다. SLT의 성공률은 65.4%, 반대안 안압을 보정한 성공률은 53.9%였다. 시술 전 안압만이 SLT 성공과 유의한 상관관계를 보였고, 시술 전 안압이 높을수록 시술 후 안압하강이 크게 나타났다(p=0.025). 나이와 시야검사의 mean deviation은 SLT 성공과 유의한 상관관계가 없었다(p=0.066, p=0.464). 결론: 개방각녹내장 환자에서 SLT는 안전하고 효과적인 치료 방법이며, 시술 전 안압만이 SLT의 성공과 유의한 상관관계를 보였다. 정확한 치료 효과 분석을 위하여 반대안의 안압 변동을 고려하여야 하겠다.

      • KCI등재

        난시교정인공수정체 삽입 후 후기 합병증으로 회전이 발생한 증례

        김현우,이상희,이종은,이규원,서샘 대한안과학회 2022 대한안과학회지 Vol.63 No.12

        목적: 난시교정인공수정체 삽입 10개월 이후 인공수정체 난시축 회전이 발생한 증례를 보고하고자 한다. 증례요약: 44세 남자 환자가 우안에 초음파수정체유화술 및 난시교정 인공수정체(AcrySof IQⓇ Toric, Alcon Laboratories, Inc., Fort Worth, FL, USA) 삽입수술을 시행하였다. 술 전 시력은 우안 0.2, 좌안 0.3이었으며, 각막난시는 우안 -2.25 diopter (D), 축 175°, 좌안 -2.5 D, 축 178°였다. 수술은 특별한 문제없이 진행되었고 술 후 10개월까지 인공수정체의 난시축은 처음 삽입한대로 85°로유지되었으며, 시력은 1.0이었다. 술 후 11개월째 인공수정체 난시축 회전이 시계방향으로 50° 발생하여 시력이 저하되었으며 수정체낭팽창고리 삽입 후에도 술 후 1주일째 다시 난시축 회전이 발생하여 일반인공수정체(enVistaⓇ MX60, Bausch & Lomb, Rochester, NY, USA)로 교체수술을 진행하였다. 결론: 난시교정인공수정체 삽입 후 장기간이 지난 뒤에도 인공수정체 난시축 회전이 발생할 수 있으므로 주의해야 하겠다.

      • KCI등재

        섬유주절제술과 백내장 병합수술 후 굴절력 오차의 분석

        이준석,이종은,박지혜,서샘,이규원 대한안과학회 2018 대한안과학회지 Vol.59 No.12

        Purpose: We evaluated the postoperative accuracy of intraocular lens power prediction for patients undergoing phacotrabeculectomy and identified preoperative factors associated with refractive outcome in those with primary open-angle glaucoma (POAG). Methods: We retrospectively reviewed the medical records of 27 patients who underwent phacotrabeculectomy to treat POAG. We recorded all discrepancies between predicted and actual postoperative refractions. We compared the data to those of an age- and sex-matched control group that underwent uncomplicated cataract surgery during the same time period. Preoperative factors associated with the mean absolute error (MAE) were identified via multivariate regression analyses. Results: The mean refractive error of the 27 eyes that underwent phacotrabeculectomy was comparable to that of the 27 eyes treated via phacoemulsification (+0.02 vs. –0.01 D, p = 0.802). The phacotrabeculectomy group exhibited a significantly higher MAE (0.65 vs. 0.35 D, p = 0.035) and more postoperative astigmatism (–1.07 vs. –0.66 D, p = 0.020) than the phacoemulsification group. The preoperative anterior chamber depth (ACD) and the changes in the postoperative intraocular pressure (IOP) were significantly associated with a greater MAE after phacotrabeculectomy. Conclusions: POAG treatment via combined phacoemulsification/trabeculectomy was associated with greater error in terms of final refraction prediction, and more postoperative astigmatism. As both a shallow preoperative ACD and a greater postoperative change in IOP appear to increase the predictive error, these two factors should be considered when planning phacotrabeculectomy. 목적: 원발개방각녹내장 환자에서 섬유주절제술과 백내장수술을 동시에 시행하는 경우 술 후 예측 굴절력의 정확성을 분석하고, 굴절력 오차에 영향을 미치는 요소에 대해 알아보고자 한다. 대상과 방법: 섬유주절제술과 백내장수술을 동시에 시행한 원발개방각녹내장 환자 27명을 대상으로 후향적으로 분석하였다. 술 후 예측 굴절력과 실제 굴절력을 비교하였으며 평균예측오차와 평균절대예측오차를 계산하였다. 같은 시기에 백내장수술만 단독 시행한 나이와 성별이 짝지어지는 대조군과 굴절력 오차를 비교하였다. 또한 굴절력 오차에 영향을 미치는 환자의 수술 전 인자들에 대하여 통계학적으로 분석하였다. 결과: 술 후 평균예측오차는 섬유주절제술과 백내장수술의 병합수술군에서 +0.02 ± 0.92디옵터, 대조군에서 -0.01 ± 0.45디옵터로 유의한 차이는 없었다. 평균절대예측오차는 병합수술군에서 0.65 ± 0.64디옵터, 대조군에서 0.35 ± 0.28디옵터로, 술 후 난시는 병합수술군에서 -1.07 ± 0.65디옵터, 대조군에서 -0.66 ± 0.48디옵터로 병합수술군에서 유의하게 높았다(p=0.035, p=0.020). 술 전 앞방깊이, 술 후 안압 변화가 부정확한 평균절대예측오차와 유의한 연관성을 보였다. 결론: 원발개방각녹내장 환자에서 섬유주절제술과 백내장수술을 동시에 시행하는 경우 술 후 예측 굴절력의 정확성이 떨어지고, 더 큰 난시를 유발하는 것으로 나타났다. 술 전 얕은 앞방깊이, 술 후 큰 안압 변화가 굴절력 오차를 증가시키므로 이를 고려하여야 하겠다.

      • KCI등재

        응급실에서 지연 진단된 급성폐쇄각녹내장 환자에 대한 고찰

        박지웅(Ji Woong Park),서샘(Sam Seo),이종은(Chong Eun Lee) 대한안과학회 2020 대한안과학회지 Vol.61 No.12

        Purpose: To analyze the clinical features of delayed diagnosed acute angle-closure glaucoma (AACG) patients who were misdiagnosed with neurologic disease in an emergency room (ER). Methods: This study was conducted with a total of 77 patients (77 eyes) who had been diagnosed with AACG in the ER. Age, gender, laterality, best-corrected visual acuity (BCVA) of the affected eye at the time of the ER visit and at an outpatient clinic follow-up examination, bilateral intraocular pressure (IOP) at time of visit, previous eye-disease history, previous history of ophthalmic surgery, underlying systemic disease including metabolic syndrome, previous neurologic disease history, referral source, chief complaint, past history of migraine, residence, and specialty of the initial doctor in charge of the ER were statistically analyzed. Results: Among the 77 patients, 34 received a delayed diagnosis and 43 were diagnosed in a timely manner. Higher cases of delayed diagnosis were observed in patients who had lower BCVA at the time of the ER visit (p = 0.001), nonophthalmologic referral source visiting the ER (p < 0.001), a chief complaint of extra-ocular symptoms (p < 0.001), and a non-ophthalmologist as the initial doctor in charge of the ER (p < 0.001). None of the other factors, including IOP, previous eye-disease history, previous ophthalmic surgery, underlying systemic disease including metabolic syndrome, previous neurologic disease history, past history of migraine, or residence showed any statistically significant intergroup difference. Conclusions: Among the AACG patients visiting the ER, many were delayed in their diagnosis and thus required much attention afterwards. Careful examination and a detailed recording of a patient’s medical history by an ophthalmologist is important for accurate and timely diagnosis in the ER. 목적: 응급실에 내원한 급성폐쇄각녹내장 환자 중 신경학적 질환으로 오인되어 지연 진단된 환자들의 임상특징을 분석하고자 한다. 대상과 방법: 응급실을 통해 내원하여 급성폐쇄각녹내장으로 진단 받은 77명(77안)명의 환자들을 분석하였다. 나이, 성별, 안측별 분포, 내원 당시 최대교정시력, 이후 외래로 추적 관찰시 이환된 눈의 최대교정시력, 내원 당시 안압, 안과 질환력, 안과수술력, 대사성증후군을 포함한 전신질환 과거력, 이전 신경학적 질환력, 내원 경로, 주호소 증상, 편두통 과거력, 거주지, 응급실 초진 의사를 확인하여 신경학적 질환으로 오인되어 지연 진단될 위험요인을 통계적으로 분석하였다. 결과: 77명 중에 지연 진단된 군은 34명, 적시 진단된 군은 43명이었다. 두 군에서 응급실 내원 당시 최대교정시력이 낮은 경우(p=0.001), 안과 전문의를 통하지 않은 내원 경로로 응급실로 방문한 경우(p<0.001), 안외 증상이 주호소 증상이었던 경우(p<0.001), 응급실 초진 의사의 전문 과목이 안과가 아닌 경우(p<0.001)에서 지연 진단된 경우가 많았다. 치료 전 안압, 안과 질환력, 안과수술력, 대사성 증후군을 포함한 전신질환 과거력, 이전 신경과적 질환력, 편두통 과거력, 거주지 요인은 지연 진단 여부와 유의한 관계를 보이지 않았다. 결론: 응급실로 내원한 급성폐쇄각녹내장 환자 중 지연 진단되는 경우가 많아 이에 대해 주의를 요한다. 응급실에 내원한 안증상을 동반한 환자에서 안과 의사의 정확한 병력청취가 급성폐쇄각녹내장을 적시에 진단하는 데 도움이 될 것으로 생각된다.

      • KCI등재

        마스크 착용이 골드만압평안압계로 측정한 안압에 미치는 영향

        최우석(Woo Seok Choi),이창훈(Chang Hoon Lee),이종은(Chong Eun Lee),서샘(Sam Seo),이규원(Kyoo Won Lee) 대한안과학회 2022 대한안과학회지 Vol.63 No.1

        목적: COVID-19 유행으로 인해 마스크 착용이 의무화된 시대에 마스크 착용이 안압 측정에 미치는 영향을 알아보고자 한다. 대상과 방법: 건강한 성인 30명 60안을 대상으로 전향적 연구를 시행하였다. 일회용 덴탈마스크, Korean Filter (KF)94 2단 세로접이형 보건용 마스크, KF94 3단 가로접이형 보건용 마스크, 방진마스크 총 네 가지의 마스크를 착용 후 골드만압평안압계를 이용하여 안압을 측정하였다. 마스크 착용 전에 비하여 안압이 5 mmHg 이상 차이 나는 경우는 두 가지 골드만압평안압계 기종을 이용하여 오차를 분석하였다. 결과: 마스크 착용 전 평균 안압은 13.7 ± 1.7 mmHg였다. 일회용 덴탈마스크, KF94 2단 세로접이형 보건용 마스크, KF94 3단 가로접이형 보건용 마스크, 방진마스크 착용 후 안압은 각각 13.5 ± 2.1, 14.0 ± 2.3, 14.3 ± 2.5, 13.8 ± 1.6 mmHg로 통계적으로 유의한 차이를 보이지 않았다(p=0.635). KF94 3단 가로접이형 마스크 착용군에서 안압 측정 시 마스크와 안압계 연결 부위의 접촉이 있었던 총 3안에서 5 mmHg 이상의 안압 오차를 보였다. 결론: KF94 3단 가로접이형 보건용 마스크 착용 후 골드만압평안압계를 이용한 안압 측정은 안압계의 연결부와 마스크와의 접촉으로 인한 오차가 발생할 가능성이 있다. 이러한 경우 마스크를 눌러서 접촉을 없애거나 다른 형태의 마스크를 착용한 후 안압을 측정하는 것이 정확한 안압 측정에 도움이 되겠다. Purpose: The corona virus disease-19 (COVID-19) pandemic has resulted in mandatory masking of patients and physicians during outpatient visits. This study evaluated the changes in intraocular pressure (IOP) according to mask use. Methods: This prospective study enrolled 30 healthy volunteers (60 eyes). IOP was measured via Goldmann applanation tonometry (GAT) for the subjects wearing one of four commonly used masks: dental, bi-folding Korean Filter (KF)94, tri-folding KF94, and dust masks. Subjects with IOP measurement errors of more than 5 mmHg were rechecked with another GAT type. Results: The mean IOP measured via GAT before mask wearing was 13.7 ± 1.7 mmHg. It was 13.5 ± 2.1, 14.0 ± 2.3, 14.3 ± 2.5, and 13.8 ± 1.6 mmHg with the dental, bi-folding KF94, tri-folding KF94, and dust masks, respectively. There were no significant differences in IOP according to mask type (p = 0.635). IOP errors above 5 mmHg were detected in three subjects who had contact between the GAT feeler arm and tri-folding KF94 mask during IOP measurement. Conclusions: The IOP as measured via GAT is artificially elevated by mechanical interference from the tri-fold KF94 mask. To minimize such mask-induced artifacts in GAT measurements, compress the patient’s mask or change the mask type to prevent any contact during measurement.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼