서병량,정만호,전준민,Seo, Byeong-Ryang,Jeong, Man-Ho,Jeon, Jun-Min 한국환경보건학회 2006 한국환경보건학회지 Vol.32 No.5
This study was performed to investigate the characteristics of indoor air quality(IAQ) in 91 public facilities from September 2004 to March 2005 in the Honam province(Chonnam, Gwangju). The measured air pollutants are $PM_{10}$, formaldehyde(HCHO), CO, $CO_{2}$ and total suspended bacteria(TSB), the maintenance standard materials of IAQ management law established by ministry of environment in Korea(MOE). We also surveyed establishment and operation of ventilation equipment. It was measured $1.2m{\sim}1.5m$ on the floor between 8 o'clock AM and 7 o'clock PM. As the result, $PM_{10}$ and CO was showed the highest concentration, $188.89{\mu}g/m^{3}$, 8.67 ppm, at the indoor parking. The concentration of HCHO was the highest in large store and steamer room. The concentration was respectively $118.70{\mu}g/m^{3}\;and\;113.21{\mu}g/m^{3}$. The concentration of $CO_{2}$ was the highest at the reading room of the library on the condition of natural ventilation. The concentration of $CO_{2}$ was 1,816 ppm and higher than the IAQ standards established by MOE. The TSB was just measured in the hospital and silver town. It was the highest at the admission room of hospital. The concentration of TSB was $766CFU/m^{3}$. The public facilities of this study were not exceed each maintenance standards except $CO_{2}$ but it was surveyed that the management will be needed about some air pollutant according to target facilities.
온.습도에 따른 건축 내장재별 휘발성유기화합물의 방출특성
서병량,김신도,박성규,Seo, Byeong-Ryang,Kim, Shin-Do,Park, Seong-Kyu 한국환경보건학회 2006 한국환경보건학회지 Vol.32 No.4
The Volatile Organic Compounds(VOCs) are emitted from various sources and have lots of different form. Recently human are spending the many times at indoor area and indoor air pollution is issued the important social problem. The emission sources of indoor air pollutants are very various, also indoor building materials are composed of very complex chemical compounds, these indoor building materials discharge very much VOCs and other hazardous compounds. In this study, we performed the small chamber test to investigate the VOCs emission concentration and characteristics involving five kinds of the indoor building materials(furniture material, wooden floor, wall paper, paint and tile) under different conditions of four temperature and relative humidity as account of the air flow rate(AFR), air exchange rate(AER), loading factor and air velocity respectively. As the result, It was showed that building materials are emitted the highest VOCs concentration at the beginning of experiment and furniture material is emitted the highest VOCs concentration. Most of the materials were affected by temperature, but paint and tile material were affected by humidity.
서병량,전학송,박영수,윤병로,장태혁,김태오 한국냄새환경학회 2013 실내환경 및 냄새 학회지 Vol.12 No.3
본 연구에서는 공공하수처리시설의 효율적인 관리방안 제시를 위하여 2008년~2010년까지 28개소의 공공하수처리시설에 대하여 복합악취와 지정악취물질(22종)을 대상으로 악취실태조사 및 원인분석을 실시하였다. 조사결과 전처리 공정과 슬러지 처리공정에서 주로 고농도의 악취가 발생되고 있었으며, 황화수소와 메틸머캅탄 등의 황화합물류가 주요 악취원인물질로 조사되었다. 공공하수처리시설에서 발생되는 악취는 유입수의 성상에 따라 차이가 있으며, 유입수에서의 복합악취는 67배~66,943배, 황화수소는 ND~66.87 ppm으로 조사되었다. A 하수처리시설 유량 조정조에서의 복합악취와 황화수소는 교반시 각각 3,000배, 6.23 ppm, 비교반시 각각 300배, 0.20 ppm으로 조사되었다. 유입 분배조와 생슬러지 분배조는 하수와 슬러지 이송 파이프 라인의 낙차에 의해 내부에 양(+)압이 형성되므로 파이프 라인의 연장과 악취포집설비를 정상적으로 설치․운영하여 내부를 음(-)압 상태로 유지할 필요가 있다. This study was performed to propose the effective management plan by the odor survey and causal analysis on dilution value and legally-designated odorants(22 compounds) of 28 public sewage treatment facilities in operation for 3 years between 2008 and 2010. As a result of this study, major odorous compounds in the research area appeared to be sulfur compounds such like hydrogen sulfide and methyl mercaptan, The highest odor concentration was detected at the pre-treatment and sludge treatment process. It was examined that the odor from public sewage treatment facility was different with appearance of sewage flows and odor dilution value of sewage flows was 67~66,943 dilution value, hydrogen sulfide was ND~66.87 ppm. Flow adjustment tank was to be examined that in case of agitating odor dilution value and hydrogen sulfide was the 3,000 dilution value, 6.23 ppm and in case of non-agitating the 300, 0.20 ppm at A. It was so formed the positive pressure by a high head of conveying fluid pipe in inflow distribution tank and raw sludge distribution tank that it was necessary to maintain the negative pressure by the extension of conveying fluid pipe and the proper installation and operation of ventilation system.