산업용 냉각기의 열부하 변화에 대응한 정밀온도제어 특성
백승문(S. M. Baek),최준혁(J. H. Choi),변종영(J. Y. Byun),문춘근(C. G. Moon),정석권(S. K. Jeong),윤정인(J. I. Yoon) 한국동력기계공학회 2010 동력시스템공학회지 Vol.14 No.2
Recently, technical trend for machine tools is focused on enhancement of speed and accuracy. High speedy processing causes thermal and structural deformation of objects from the machine tools. Water cooler has to be applied to machine tools to reduce the thermal negative influence with accurate temperature controlling system. Existing On-Off control type can’t control temperature accurately because compressor is operated and stopped repeatedly and causes increment of power consumption and decrement of the expected life of compressor. The goal of this study is to minimize temperature error in steady state. In addition, control period of an electronic expansion valve were considered to increment of lifetime of the machine tools and quality of product with a water cooler. PI controller is designed using type of hot-gas bypass for precise control of temperature. Gain of PI is decided easily by method of critical oscillation response, excellent performance of control is shown with 4.24% overshoot and ±0.2℃ error of steady state. Also, error range of temperature is controlled within 0.2℃ although disturbance occurs.
백동명,윤승현,이범철,Baek, D.M.,Yoon, S.H.,Lee, B.C. 한국전자통신연구원 2015 전자통신동향분석 Vol.30 No.6
최근에 클라우드 기반으로 가상 네트워크 기능이 더해진 Network Function Virtualization(NFV)이 미래 네트워크 설계에 큰 이슈가 되고 있다. NFV는 클라우드 보다 네트워크 토폴로지가 있고, 정책에 따른 변경이 용이해야 되며, 고가용성이 요구되고, 높은 전송률 처리를 위해 고성능이어야 한다. NFV 전체 구조에서 최상위 제어기인 Orchestrator의 구조와 제품을 분석하고자 한다. NFV 제품으로는 Cyan사의 Blue Planet, HP사의 Director, Ericsson사의 Cortex Service Orchestrator, Telefornica사의 Openmano 등이 있다. 이때 소스와 GUI가 공개 된 Openmano를 분석하여 Orchestrator 이해에 도움이 되고자 한다.
백동명,윤승현,이범철,Baek, D.M.,Yoon, S.H.,Lee, B.C. 한국전자통신연구원 2013 전자통신동향분석 Vol.28 No.6
개별적으로 발달해 온 서버, 스토리지, 네트워크 기술들이 데이터 센터를 중심으로 서로 통합되어 궁극의 서비스 제공면에서 더욱 저렴하고 자동화되는 측면으로 발달하고 있다. 이에 벤더들은 개별 기술 단위를 넘어 통합 기술로 발달시키고 있다. 이를 IDC와 가트너는 통합시스템(Converged System, Integrated System)이라고 명명하였다. 이런 기술 트렌드를 개별 벤더의 제품에서 분석 확인한다. 한국의 경우에도 지역적으로 분산된 마이크로 IDC 형태를 취하면서 클라우드 지원과 텔레콤 통신지원의 통합제어를 목표로 '스마트인터넷' 프로젝트를 진행 중이다. 클라우드 지원관리의 대표 기술인 오픈스택과 텔레콤 통신자원의 새로운 기술을 요약하면서 네트워크 관점에서 통합시스템(Converged System)과 스마트 인터넷의 기술 동향을 분석해 본다.
내재적 경계조건 방법을 적용한 비정렬 격자 기반의 정상 압축성 Navier-Stokes 해석자
백청(C. Baek),김민수(M. Kim),최선규(S. Choi),이승수(S. Lee),김철완(C.W. Kim) 한국전산유체공학회 2016 한국전산유체공학회지 Vol.21 No.1
Numerical boundary conditions are as important as the governing equations when analyzing the fluid flows numerically. An explicit boundary condition method updates the solutions at the boundaries with extrapolation from the interior of the computational domain, while the implicit boundary condition method in conjunction with an implicit time integration method solves the solutions of the entire computational domain including the boundaries simultaneously. The implicit boundary condition method, therefore, is more robust than the explicit boundary condition method. In this paper, steady compressible 2-Dimensional Navier-Stokes solver is developed. We present the implicit boundary condition method coupled with LU-SGS(Lower Upper Symmetric Gauss Seidel) method. Also, the explicit boundary condition method is implemented for comparison. The preconditioning Navier-Stokes equations are solved on unstructured meshes. The numerical computations for a number of flows show that the implicit boundary condition method can give accurate solutions.
백동명,이범철,Baek, D.M.,Lee, B.C. 한국전자통신연구원 2014 전자통신동향분석 Vol.29 No.6
최근 빌링(billing, 과금), 벤치마킹, 확장성(scalability), 통계적 목적을 위해 오픈스택 클라우드의 개별 컴포넌트를 모니터링하고 메터링하는 텔레메터링 서비스가 Ceilometer라는 코드명으로 정식 프로젝트로 추가되었다. 초기의 빌링만을 위해 필수 요소만 모니터링하는 것에서, 상태를 감시하여 클라우드 자원의 오토스케일링 등의 오케스트레이션 기능을 위한 다목적성으로 발전하고 있다. 특히 이것은 빅데이터 등의 데이터 분석에 있어서 중요한 힌트를 제공해 준다. 본고는 소스분석을 통한 Ceilometer의 데이터 수집 구조, Ceilometer 모니터링의 핵심 키워드, 비정형 데이터 DB인 MongoDB, 외부인터페이스로써 API(Application Interface) 혹은 CLI(Command Line Interface) 명령어를 소개하고자 한다. 결론에서는 ceilometer의 전반적 구조에 대한 나름대로의 평가를 기술하였다.
산업용 냉각기의 용량제어 방식별 에너지 소비 변화 특성
백승문(S. M. Baek),문춘근(C. G. Moon),이동훈(D. H. Lee),곽진우(J. W. Kwag),김은필(E. Kim),윤정인(J. I. Yoon) 한국마린엔지니어링학회 2010 한국마린엔지니어링학회 학술대회 논문집 Vol.2010 No.10
This paper presents the characteristics of energy consumption change by capacity control type of industrial water cooler. Industrial water cooling capacity control compare the overall energy consumption. Hot-gas bypass capacity control system and inverter type system of change in control of the capacity factor by comparing the performance of the overall system is to compare the energy consumption. Hot-gas bypass system for capacity control by controlling the coefficient of performance from 0.52 to 2.81 and showed a change in inverter type capacity control according to the change in coefficient of performance was between 2.17 to 2.64.