http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
배연가스의 $NO_x$제거용 코로나 방전장치에서 OH 발광 스펙트럼 측정 및 관련 반응 연구
박철웅,한재원,신동남,Park, Chul-Woung,Hahn, Jae-Won,Shin, Dong-Nam 한국연소학회 1999 한국연소학회지 Vol.4 No.1
We constructed a wire-cylinder type pulsed corona discharge system for $NO_x$ removal, which was operated in room temperature. A emission spectrometer was built with a boxcar averager and monochrometer equipped with photo-multiplier tube detector. The sensitivity of the emission spectrometer was greatly improved by synchronizing the emission spectrometer with pulsed corona discharge system using a triggered spark-gap switch. $N_2$ spectrum($c^3{\Pi}_u{\rightarrow}X^1{\Sigma}_g{^+}$) was measured in the range of 300 - 450 nm and oxidizing OH radical emission($A^2{\Sigma}^+{\rightarrow}X^2{\Pi}$) was measured in case $N_2$ was supplied with water bubbling. As wet gas composition of inlet $N_2$ supplied in the discharge system increased, the intensity of OH emission was increased and saturated at wet gas composition 50%. We also investigated additive effect of $C_2H_4,\;H_2O,\;H_2O_2$ on the intensity of OR emission and $NO/NO_2/NO_x$ reduction and analysed the related reaction mechanism in corona discharge process. $H_2O_2$ additive increased the intensity of OH emission and $NO/NO_x$ reduction.
레이저 유도 격자 분광장치 제작 및 C₃H8 화염에서 열 격자 측정
박철웅(Chul Woung Park),한재원(Jae Won Hahn),이중재(Joong-Jae Lee),이영우(Young-Woo Lee),고동섭(Dong-Seob Ko) 한국광학회 2001 한국광학회지 Vol.12 No.6
레이저 유도 격자 분광장치를 제작하여, C₃H_8 층류 확산화염에서 생성된 열 격자 신호를 측정하였다. 열 격자를 생성시키기 위한 여기광은 파장이 532 ㎚인 Nd:YAG 레이저를 사용하였고, 검침광은 488 ㎚의 CW Ar+ 레이저를 이용하였다. 검침광의 세기를 변화시켜 장치의 회절효율과 신호 특성을 측정하였다. 측정된 열 격자 신호의 세기를 분석하여 화염내의 매연의 농도 분포를 정성적으로 측정하였고, 신호의 주파수 변화를 측정하여 온도 분포를 구하였다. We made a laser induced grating spectrometer(LIGS) and measured the thermal grating signal generated in a C₃H_8 flame. The thermal grating was formed in the C₃H_8 flame with two second-harmonic Nd:YAG pulse laser beams, and an LIGS signal was generated by Bragg scattering of a probe laser beam Ar+ laser(488 ㎚). We found the modulation period of the signal depends linearly on the spacing of the grating set in the flame. We determined flame temperature by fitting the modulated signal and soot concentration with signal strength. Using this technique, we also obtained temperature profile and soot-particle distribution in a C₃H_8 flame.
유용심,김봉학,박철웅,박승남,Yoo, Yong-Shim,Kim, Bong-Hwak,Park, Chul-Woung,Park, Seung-Nam 한국광학회 2010 한국광학회지 Vol.21 No.4
모든 복사온도계는 복사원 크기효과(Size-of-Source Effect, SSE)와 자기복사효과를 가지고 있다. 복사원의 직경에 따른 복사온도계의 검출기 신호세기로 정의된 SSE의 주원인은 회절이기 때문에 파장에 크게 좌우된다. 본 논문에서는 중저온영역에서 복사온도의 전달표준기로 많이 사용되고 있는 TRT2(Transfer Radiation Thermometer 2, HEITRONICS)의 SSE와 자기복사 특성을 측정하였다. 측정한 TRT2의 SSE 값을 사용하여 계산한 결과 흑체의 온도가 $300^{\circ}C$ 일 때, 개구 직경이 60 mm인 흑체와 10 mm인 흑체의 복사온도 차이가 저온모드($8-14\;{\mu}m$)에서 $3.5^{\circ}C$, 중온모드($3.9\;{\mu}m$)에서 $0.5^{\circ}C$인 것을 알 수 있었다. 또한, 복사온도계 몸체 온도가 $2.6^{\circ}C$ 변화했을 때 자기복사효과 때문에 흑체의 복사온도는 110 mK 다르게 측정되었다. All radiation thermometers have a size-of-source effect (SSE) and a self-radiation effect (SRE). The SSE,defined as dependence of the detector signal of a radiation thermometer on the diameter of a source, is critically dependent on the wavelength since diffraction is the main cause. In this paper, we have measured the SSE and the SRE of TRT2 (Transfer Radiation Thermometer 2, HEITRONICS) widely used as a transfer standard in low and middle temperature range. At $300^{\circ}C$, The radiation temperature difference between the 60 mm diameter blackbody and 10 mm diameter blackbody due to the SSE was estimated to be $3.5^{\circ}C$ in low temperature mode ($8-14\;{\mu}m$) and $0.5^{\circ}C$ in middle temperature mode ($3.9\;{\mu}m$). In addition, the measured radiation temperature difference of the blackbody due to the SRE was found to be 110 mK when the body temperature change of TRT2 was set at $2.6^{\circ}C$.
기울어진 비구면 프레넬 렌즈와 C-8 type 전구를 이용한 해상용 랜턴의 배광곡선 시뮬레이션을 통한 성능평가
조현석,조재흥,박승남,박철웅,김용완,김종태,Cho Hyun Seok,Jo Jae Heung,Park Seungl Nam,Park Chul Woung,Kim Yong Wan,Kim Jong Tae 한국광학회 2004 한국광학회지 Vol.15 No.6
대구경이 가능하며 가벼운 프레넬 렌즈로 10 해리 (18.53 km)까지 빛을 비출 수 있는 해상용 랜턴을 설계하고 배광곡선을 시뮬레이션하였다. 렌즈설계 프로그램으로 직경 250 mm와 300 mm인 프레넬 렌즈를 설계하였으며, 이 프레넬 렌즈의 groove 변수들을 최적화하였다. 해상용 랜턴에서 사용하는 전구의 배광곡선을 고려하여 이 프레넬 렌즈의 배광곡선을 조명설계 프로그램으로 계산하였다. 이 결과 전구를 최적의 위치로 정렬하였을 때 이 해상용 랜턴들의 최대광도는 각각 KS 규격인 720 cd를 훨씬 넘는 1000 cd(직경 250 mm의 해상용 랜턴의 경우)와 1300 cd (직경 300 mm의 해상용 랜턴의 경우)로 계산되었다. 그리고 전구의 정렬오차를 정하기 위하여 렌즈의 초점거리에서 벗어난 정도에 따라 배광곡선이 변하는 정도도 알아보았다. Providing marine signal lanterns with advantages of little weight as well as large aperture, a Fresnel lens has been adopted to transfer the beam from the lanterns up to 10 nautical miles (18.53 km). A Fresnel lens with the diameter of 250 mm and 300 mm was designed by a lens design program and optimized by adjusting the groove parameters of the lens. The angular luminous intensity distribution (ALID) of this lens was calculated by using an illumination analysis program considering the ALID of a light bulb. At the best alignment of the bulb, the maximum luminous intensities (MLI) of the lantern were 1000 cd (in the case of 250 mm diameter) and 1300 cd (in the case of 300 mm diameter). These are more than the critical value of 720 cd that is the Korean Standard of MLI for the marine lantern. The ALID was investigated as a function of misalignment from the lens focus to determine the tolerance of the alignment ranges.