RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        웨이블릿 변환을 이용한 일반화된 서브밴드 분해 FIR 적응 필터의 구조와 수렴특성 해석

        박순규,박남천,Park, Sun-Kyu,Park, Nam-Chun 한국융합신호처리학회 2008 융합신호처리학회 논문지 (JISPS) Vol.9 No.4

        In general, transform domain adaptive filters show faster convergence speed than the time domain adaptive filters, but the amount of calculation increases dramatically as the filter order increases. This problem can be solved by making use of the subband structure in transform domain adaptive filters. In this paper, to increase the convergence speed on the generalized subband decomposition FIR adaptive filters, a structure of the adaptive filter with subfilter of dyadic sparsity factor in wavelet transform domain is designed. And, in this adaptive filter, the equivalent input in transform domain is derived and, by using the input, the convergence properties for the LMS algorithm is analyzed and evaluated. By using this sub band adaptive filter, the inverse system modeling and the periodic noise canceller were designed, and, by computer simulation, the convergence speeds of the systems on LMS algorithm were compared with that of the subband adaptive filter using DFT(discrete Fourier transform). 변환영역 적응필터는 시간영역 적응필터보다 일반직으로 수렴속도가 빠르지만 필터의 차수가 증가함에 따라 계산량이 크게 증가한다. 이러한 문제점은 변환영역 적응필터를 서브밴드 분해구조로 변경함으로써 해결할 수 있다. 이 논문에서는 일반화된 서브밴드 분해 FIR 적응 필터의 수렴속도 향상을 위해 웨이블릿 변환영역에서 다이아딕 희소인자 서브필터를 가지는 일반화된 서브밴드 분해 FTR 적응 필터의 구조를 설계하였다. 그리고 이 적응필터에서 변환영역의 일반화된 등가입력을 유도하고 이 입력을 이용하여 LMS 일고리듬에 대한 수렴특성을 해석 및 평가하였다. 이 서브밴드 FIR 적응필터를 이용하여 역 모델링 시스템과 주기성 잡음제거기를 구성하고 LMS 알고리듬 대한 이 시스템들의 수련속도를 이산푸리에 변환을 이용한 서브밴드 적응필터의 것과 컴퓨터 모의실험으로 비교하였다.

      • KCI등재

        R&D 지원 유용성 인지, 기술혁신 및 사업화역량 관계에 있어서 진성리더십의 조절효과

        박순규(Sun-Kyu Park),이홍배(Hong-Bae Lee) 한국산업경제학회 2015 산업경제연구 Vol.28 No.1

        본 연구의 목적은 대구·경북지역 157개 기술창업 기업을 대상으로 R&D 지원 유용성 인지와 기술혁신 및 사업화역량이 경영성과에 미치는 영향을 살펴보고, 이들 관계모형에 있어서 긍정조직행태 중의 하나인 진성리더십의 조절효과를 분석하였다. 이를 위해 본 연구에서는 구조방정식모형 분석을 사용하였다. 분석결과, 중소기업 R&D 지원정책의 유용성 인지는 향후 직접적인 R&D 지원정책 성과에 대한 사전 예측지표로써 매우 의미 있는 지표가 될 수 있음을 확인하였다. 그리고 진성리더십의 하위요인 중 특히 도덕성 수준, 자기인식 수준이 기술역량 관계구조에서 매우 중요한 조절효과가 있음을 확인하였다. 이는 중소기업들에 대한 R&D 지원정책 수립과 지원사업의 시행에 있어 유용성을 높게 인지하는 기업과 진성리더십을 발휘하는 CEO를 대상으로 방향성을 집중함으로써, 보다 정부의 R&D 지원정책을 효율적으로 집행하고 성과제고에도 기여할 수 있음을 시사하고 있다. The purpose of this paper is to look closely into the influence that perceived usefulness of government R&D support has on technological capability, technology commercialization capabilities and managerial performance of startups, and finding out the moderating effect of the authentic leadership. We suggest that the perceived usefulness of CEO influences managerial performance(financial performance, customer performance, operating performance) positively by the mediating variables of the technology innovation capability(R&D capabilities, technology accumulation ability, innovation systems) and technology commercialization capabilities(commercialization capabilities, production Capacity, marketing skills). And we suggest that the higher the levels of authentic leadership(especially, morality and self-consciousness), the more significantly technology innovation capability and technology commercialization capability influence managerial performance. We use the structural equation model analysis to test the hypothesis.

      • R&D지원 유용성 인지, 기술혁신 및 사업화역량 관계에서의 긍정적 심리자본 매개효과

        박순규(Park, Sun-Kyu),이홍배(Lee, Hong-Bae),오태원(Oh, Tai-Won) 한국의사결정학회 2015 의사결정학연구 Vol.23 No.2

        본 연구는 기술혁신 및 기술 사업화 성과에 있어서 긍정조직행태 중의 하나인 긍정적 심리자본의 매개효과를 분석하였다. 분석 이전에 대구․경북지역 157개 기술창업 기업을 대상으로 R&D지원 유용성 인지와 기술혁신 및 사업화역량이 경영성과에 미치는 영향 관계를 검토하였다. 이를 위해 본 연구에서는 구조방정식모형 기법을 사용하였다. 분석결과, 중소기업 R&D 지원정책의 유용성 인지가 R&D 지원정책 성과에 대한 사전 예측지표로써 매우 의미 있는 지표가 될 수 있음을 확인하였다. 그리고 긍정적 심리자본의 매개변수로서의 역할을 분석결과, 조직 구성원들의 긍정 마인드를 나타내는 긍정적 심리자본은 매우 중요한 매개변수로서의 역할을 하고 있음을 확인하였다. 이 결과로 향후 정부의 R&D 지원정책 수립과 지원사업의 시행에 있어 긍정적인 기업의 조직 분위기를 사전 검토함으로써, 정부의 R&D 지원정책을 효율적으로 집행하고 성과제고에도 기여할 수 있음을 시사하고 있다. The purpose of this paper is to review the mediating effect of the Positive Psychology Capita on the perceived usefulness of government R&D support policy-technology innovation system model. Formerly, we look closely into the influence that perceived usefulness of government R&D support has on technological capability, technology commercialization capabilities and managerial performance of startups. We suggest that SME R&D support policy influences managerial performance(financial performance, customer performance, operating performance) positively through the mediation of the technology innovation capability(R&D capabilities, technology accumulation ability, innovation systems) and technology commercialization capabilities(commercialization capabilities, production Capacity, marketing skills). And also, we find the mediating effect of the positive psychology capital. We use the structural equation model analysis to test the hypothesis.

      • KCI등재

        건설기업 신입사원의 내부마케팅 활동과 기업성과 간의 관계 연구

        박순규(Park, Soon-Kyu),이종선(Lee, Jong-Sun) 대한건축학회 2012 大韓建築學會論文集 : 構造系 Vol.28 No.11

        Due to the recent economic downturn, many construction companies are facing difficulty on running their business. In order to overcome these difficulties, they are focused on developing their competitiveness. However, the importance of competitive advantage achievable through existing patents and technology, ensuring the protection and market regulation, and financing capacity and economies of scale have diminished recently. Traditional construction industry which resemble the characteristics of manufacturing and services industry had retained its competitiveness through rigidly mass supplying its deliverables up until modern days. However the current domestic construction market now undergoes transformation by attempting various changes through an introduction and phasing in of a customer focused services as a means of adapting into the ever changing market environment. The primary study has taken place for the strategic adoption of a successfully attempted internal marketing theory which states that “To satisfy the external customers, satisfaction of internal staff has to be met” This study has revealed that critical components within ‘internal marketing’ composition had strong influence over the specific construction firm. Hence this text proposes the ways in which ‘internal marketing’ approach can be used for the betterment of managing a construction organization.

      • KCI등재

        건설기업 내부마케팅 구성요인과 기업성과 간의 관계 연구 - 시공사 임직원을 대상으로 -

        이종선,박순규,Lee, Jong-Sun,Park, Soon-Kyu 한국건설관리학회 2013 한국건설관리학회 논문집 Vol.14 No.2

        Recent economic slump is making the construction industry's overall construction business environment worse. Contractors which are under the legal management and/or walk out are to the brink of 25 companies according to the Construction association of Korea released in 2011. It means that existing construction companies are required to transform the fundamental ideology of existing operation framework, and besides, existing companies should be transformed to service industry in order to proceed further into the developing future industries. In this study, it will be chosen the internal marketing related factor like 'Satisfying employees, internal customer, are the first thing to do in order to satisfy external customer.' which is about existing service industry field before its implementation in construction companies. In addition, appropriateness test will be performed including both interactions between each of the factors affect mutually and looking into any management improvement effects on contractors. And also, this proposal is suggested by approaching with internal marketing strategy which is both paradigm shift for customers by construction company members and another internal communication way as a means of overcoming the crisis of overall construction industry under currently happening. 최근 경기침제는 건설 산업의 전반적 건설기업환경을 악화시키고 있다. 2011년 대한건설협회 발표에 따르면 2008년 이후 워크아웃 및 법정관리 중인 건설사는 25개사에 이른다. 이는 기존 건설기업을 운영하는 틀과 사고((思考)에 대한 근본적인 변화를 요구하는 것이다. 지금부터 건설 산업은 서비스업이 되어야 하며, 또한 미래 성장산업으로 뻗어나가려면 서비스업으로 변신해 나가지 않으면 안 된다. 이에 본 연구는 기존 서비스산업분야의'외부고객의 만족을 위해서는 내부고객인 종사원의 만족이 우선이다.' 라는 내부마케팅을 건설기업에 시행(도입, 적용) 및 활동에 앞서 내부마케팅관련 구성요인을 선정하려한다. 또한 각 구성요인들 간에 어떠한 영향을 미치며, 시공사에 기업성과가 있는지 검정하려한다. 그리고 그동안 등한시 하였던 건설기업 구성원의 고객 지향(의식, 인식)적 사고의 전환 도구로, 내부 소통의 도구로 또한 현재 처하고 있는 건설 산업의 위기를 극복하기 위한 방편으로 건설기업에도 내부마케팅의 시행 및 활동을 제안 하고자 한다.

      • 소아 투시검사 시 필터 사용에 따른 피폭선량 감소

        전선우(Sun-Woo Jeon),정지상(Ji-Sang Jung),안치복(Chi-Bok An),김성식(Sung-Sik Kim),박순규(Soon-Kyu Park),임재식(Jae-Sik Im) 대한영상의학기술학회 2016 대한영상의학기술학회 논문지 Vol.2016 No.1

        목 적 : 본 연구는 소아의 투시검사 시 filter를 사용하여 영상의 질 변화없이 피폭선량 감소 변화에 대해 알아보고자 하였다. 대상 및 방법 : 실험에 사용된 장비는 TOSHIBA사의 BLF-15B와 0세 소아 Phantom 704-G에 15cm x 20cm 조사야, SID 110cm, 80kv에 AEC mode로 1분동안 X-ray를 조사하였다. Filter는 DAP meter위에 고정시켰고, 0.1mmCu filter와 0.2mmAl filter를 사용하였다. <실험1> 15f/s에서 filter를 사용하지 않고 80kv AEC mode로 1분 동안 X-ray를 조사하였다. <실험2> 7.5f/s에서 filter를 사용하지 않고 <실험1>과 동일한 방법으로 실험하였다. <실험3> 15f/s에서 0.1mmCu filter를 사용하여 <실험 1>과 동일한 방법으로 실험하였다. <실험4> 15f/s에서 0.1mmCu filter+0.2mmAl filter를 사용하여 <실험1>과 동일한 방법으로 실험하였다. DAP meter를 이용해 면적선량을 구했고, unfors사의 Patiant skin dosimeter를 이용해 입사선량을 구하고 NRBP 검사별 변환계수를 사용하여 유효선량을 구했다. 움직임에 의한 영상화질 평가는 NEMA XR21의 moving wire targets을 이용해 pulse rate에 따른 wire 관측 여부를 평가하였고, SNR은 ROI 영역과 Background 영역의 평균과 표준편차 값으로 구했다. 결 과 : 면적선량은 각각 417.25mGycm2, 204. 24mGycm2, 148mGycm2, 146.75mGycm2로 나왔고, 15f/s에 filter를 사용하지 않았을 때보다 15f/s에 0.1mmCu+0.2mmAl filter를 사용하였을 때가 약 65% 감소하였다. SNR은 각각 24.11, 14.34, 30.87, 30.51로 나왔고 15f/s에 filter를 사용하지 않았을 때보다 15f/s에 0.1mmCu+0.2mmAl filter를 사용하였을 때가 약 21% 증가하였다. 유효선량은 각각 0.1085mSv, 0.0531mSv, 0.0385mSv, 0.0382mSv로 나왔고 15f/s에 filter를 사용하지 않았을 때보다 15f/s에 0.1mmCu+0.2mmAl filter를 사용하였을 때가 약 65% 감소하였다. 결 론 : 소아투시 검사 시 15f/s으로 filter를 적절히 사용한다면 영상의 질을 저해하지 않으면서 소아의 피폭선량을 줄일 수 있다고 사료된다. Purpose : The purpose of this examine was investigate the dose reduction without changing the quality of the image according to using filter in pediatrics fluoroscopy studies. Materials and Methods : The experiment exposed the X-ray for 1 minute with 80kv AEC mode, SID 110cm, collimation 15cm x 20cm with TOSHIBA Corporation BLF-15B and 704-G 0 aged pediatric phantom. filter is fixed on the DAP meter, it was used 0.1mmCu filter and 0.2mmAl filter. <experiment 1> With 15f/s and no filter, X-ray is exposed for 1 minute with 80kv AEC mode. <experiment 2> With 7.5f/s and no filter ,take same method as <experiment 1> <experiment 3> With 15f/s and 0.1mmCufilter ,take same method as <experiment 1> <experiment 4> With 15f/s and 0.1mmCu+0.2mmAl filter ,take same method as <experiment 1> Dose area was measured using DAP meter and absorbed dose was measured using unfor’s Patiant skin dosimeter, it was used to obtain the effective dose. Depending on the pulse rate change, Image quality evaluation by the movement was evaluated by using a moving wire targets of the NEMA XR 21 according to visible wire. SNR was determined by average of ROI area and standard deviation of background area. Result : Area dose was measured to 417.25mGycm2, 204.24mGycm2, 148mGycm2, 146.75mGycm2 and Area dose used to 15f/s was reduced by appro ximately 65% when using the 0.1mmCu +0.2mmAl filter compared with no filter. SNR was measured to 24.11, 14.34, 30.87, 30.51 and SNR used to 15f/s increased by approximately 21% when using the 0.1mmCu +0.2mmAl filter compared with no filter. effective dose was measured to 0.1085mSv, 0.0531mSv, 0.0385mSv, 0.0382mSv and effective dose used to 15f/s was reduced by approximately 65% when using the 0.1mmCu +0.2mmAl filter compared with no filter. Conclusion : By using of filter in pediatrics fluoroscopy studies, it is considered to reduce the radiation of children without changing the quality of the image.

      • Rib Cage View검사 시 촬영조건 변화에 따른 적정선량 및 영상 평가

        김선재(Sun-Jae Kim),이호일(Ho-Il Lee),안치복(Chi-Bock An),손영목( Yung-Mok Son),김윤국(Youn-Kook Kim),박순규(Soon-Kyu Park) 대한영상의학기술학회 2018 대한영상의학기술학회 논문지 Vol.2018 No.1

        목 적:디지털 방사선 X-ray장비에서 Rib Cage검사 시 Deviation Index (DI)를 활용하여 적정선량을 평가하고 의학적 목적에 맞는 최적의 노출조건을 표준촬영조건과 비교하여 평가하고자 한다. 대상 및 방법: 실험에 사용된 장비는 디지털 방사선 장치(Samsung GC85A)와 다목적 흉부팬텀(Lungman)을 사용하였다. 관전압을 50kVp부터 80kVp까지 5단계로, 관전류를 10mAs부터 50 mAs까지 10단계로 나누어 총 35개의 영상을 획득하였으며, 촬영 조건에 따라 획득한 영상들의 Deviation Index (DI)를 활용하여 적정 에너지 값을 갖는 촬영 조건을 획득하였다. 획득된 영상들을 정량적 평가를 위해 Image J 프로그램을 이용하여 갈비뼈(Rib)와 폐(Lung)에 동일한 관심영역(ROI)을 설정하여 신호 대 잡음 비(SNR)를 산출하였으며, 영상의 학과 전공의 1명과, 방사선사 3명이 정성적 평가를 실시하였고, Dose Area Product (DAP)를 획득 후 PCXMC (Dose Calculation)프로그램을 이용하여 유효선량을 산출하였다. 모든 값들은 식약청에서 정해선 표준촬영조건 과 비교하였으며, 모든 통계학적 검정은 SPSS (Ver.18)를 이용하여 분석하였다. 결 과:조건에 따른 DI는 80 kVp 10mAs에서 -0.07, 60 kVp 40mAs에서 -0.28로 이 두 조건이 유효범위 안에 가장 가깝게 평가되었고, 평가된 두 조건을 표준 촬영조건인 75kVp 30 mAs와 비교하였다. SNR은 각각 9.1%, 17.4%로 감소하였고, 유효선량은 각각 61%, 45.3%로 감소되었으며, 정성적 평가 결과 각각 3.6점, 4.6점으로 나타났다. 결 론:60 kVp 40 mAs조건이 80 kVp 10 mAs조건 보 다 약간의 낮은 수치를 보였지만 정성적 평가에서 높은 점수를 받았고, 임상적 목적에 따라 요구되는 영상의 품질 수준이 높기 때문에, 60 kVp 40mAs조건이 진단적 가치가 좋은 영상일 뿐만 아니라 환자의 피폭선량을 줄일 수 있는 적정선량이 조사되었다고 사료된다. Purpose:When examining Rib Cage, Digital equipment is to be found to assess the appropriate dose by using a Deviation Index (DI) and compare the optimal exposure conditions for medical purposes with standard imaging conditions. Materials and Methods:The equipment used for the experiment used a digital radiation device (Samsung GC85A) and a multipurpose chest phantom (Lung-man). Tube voltage was divided into 5 units from 50 kVp to 80 kVp and Tube current was divided into 10 units from 10 mAs to 50 mAs to obtain a total of 35 images. Using the Deviation Index (DI) of the images acquired according to the exposure conditions, the exposure conditions with appropriate energy values were selected. The selected ROI was set in the Rib and Lung using ImageJ, and SNR and CNR were calculated. One person in the Radiology resident and three from the Radiological technologist conducted onducted a qualitative evaluation. After obtaining Dose Area Product (DAP), effective dose was calculated using PCXMC (Dose Calculation) program. All values were compared from the Ministry of Food and Drug Safety to the decision line standard photographing condition, and all statistical tests were analyzed using SPSS (Ver.18). Result:According to the condition, DI was –0.07 at 80 kVp 10 mAs, -0.28 at 60 kVp 40 mAs, it was found that these two conditions were the most appropriate dose. Therefore, the two conditions selected were compared with 75 kVp 30 mAs which is the standard exposure condition. Although the SNR decreased to 9.1% and 17.4% respectively, there was no significant difference as a result of the SPSS statistical test (P<0.191). Effective amounts are 61%, 45.3%, reduced, Qualitative evaluation resulted in 3.6 and 4.6 points, respectively. Conclusion:The condition of 60 kVp 40 mAs was slightly lower than the condition of 80 kVp 10 mAs. However, because the qualitative evaluation received a very high score and the quality level of the image required is clinically high according to the purpose, the condition of 60 kVp 40 mAs can be used not only for images with high diagnostic value, Appropriate dose that can reduce exposure dose This is considered to have been investigated.

      • KCI등재

        SAW를 이용한 반절연 GaAs웨이퍼 표면 성질의 비파괴 측정

        박남천,박순규,이건일,Park, Nam-Chun,Park, Sun-Kyu,Lee, Kuhn-Il 한국음향학회 1991 韓國音響學會誌 Vol.10 No.3

        SAW와 반도체가 상호작용할 때 발생되는 횡음전전압을 이용하여 반절연 GaAs 웨이퍼 표면의 에너지 갭, 엑시톤, 얕은 준위 트랩, 깊은 준위 트랩, 어닐링 후의 형반전, $EL_2$ 준위의 준안정 상태 그리고 Cr이 첨가된 2인치 GaAs 웨이퍼의 전자 농도 분포를 비파괴적으로 측정평가 하였다. 또한 SAW를 발진기를 이용한 반도체 표면성질의 측정을 새로이 시도하고 이의 실용성을 밝혔다. The surface properties such as energy gap, exciton, shallow trap level, deep trap level, type inversion with annealing and metastable state of $EL_2$ level of SI GaAs wafers and the conductivity distribution of 2 inch Cr doped GaAs wafer were investigated using nondestructive TAV(transverse acoustoelectric voltage) technique. The TAV is generated when SAW and semiconductor interact. We also have tried newly SAW oscillator technique to investigate the surface properties of semiconductor wafers and we have shown the validity of this technique.

      • DR wireless detector를 이용한 abdomen upright 검사 시 grid 사용에 따른 cut-off 현상을 줄일 수 있는 최적의 X선 입사각도 고찰

        심현보(Hyeon-Bo SIM),정지상(Ji-Sang Jung):안치복(Chi-Bok Ahn),박순규(Sun-Kyu Park),임재식(Jae-Sik Lim) 대한영상의학기술학회 2017 대한영상의학기술학회 논문지 Vol.2017 No.1

        목 적:이동형 침대에서 abdomen upright 검사 시 obese patient 경우 DR wireless detector에 grid를 사용하여 검사를 진행한다. 이때 X선 입사각도와 detector의 기하학적 위치에 따라 cut-off 현상이 발생 할 수 있으며, 이러한 cut-off 현상의 영향을 줄일 수 있는 최적의 X선 입사각도의 범위를 알아보고자 한다. 대상 및 방법:X선 발생장치와 DR wireless detector 에 parallel gird (ratio 10:1)를 사용한 후 복부팬텀을 이용하여 abdomen upright 검사를 재현 하였다. 관전압은 70 kVp, 관전류는 20 mAs, SID는 130 cm로 촬영 조건을 설정하고 detector는 length로 위치하였다. 실험1)튜브 각도 0˚기준으로 음극 방향으로 5˚증가하여 30˚까지 변화를 주었고 detector의 기하학적 변화는 팬텀의 횡단면에 90˚(수직)와 앞뒤로 ±10˚,±20˚ 기울어진 설정을 하였다. 실험2)튜브 각도 0˚기준으로 음극 방향으로 5˚증가하여 15˚까지 변화를 주었고 detector의 기하학적 변화는 팬텀의 관상면에 평행을 기준으로 옆으로 5˚, 10˚ 기울어진 설정을 하였다. detector의 기하학적 변화에 따라 튜브 각도를 각각 적용 시켰으며 획득된 영상은 방사선사 3명이 리커트척도를 이용한 육안적 평가와 Image J 프로그램을 이용한 동일한 관심영역의 신호 평균값 및 표준편차를 측정하였다. 측정된 값으로 대조도잡음비를 산출하여 영상을 비교하였고, 통계학적 검정은 Kruskal-wallis test 와 Mann-Whiteny와 대응표본 t검정으로 유의성을 분석하였다. 결 과:정량적인 평가는 실험1)의 대조도대 잡음비는 튜브 각도가 0˚/5˚/10˚/15˚/20˚/25˚/30˚일 때 평균 11.29/10.62/10.27/9.34/6.74/4.61/3.63로 통계적으로 유의한 차이가 있었다.(p〈0.05). 실험2)는 각각의 튜브 각도가 0˚/5˚/10˚/15˚일 때 평균 9.37/8.19/6.73/6.29 였지만 통계적으로 유의한 차이가 없었다.(p〉0.05). 실험1)에서 튜브 각도가 15˚에서 20˚ 사이에서 대조도대잡음비는 가장 크게 감소하였다. 정성적인 평가 결과에서 실험1)은 응답자의 평균 점수와 Kruskal-wallis test 순위 검정 결과 튜브 각도가 15˚/20˚일 때 평균 4.5점/2.8점, 순위 67.9/37.2 이였고 실험2)에서는 튜브 각도가 5˚/10˚일때 평균 3.6점/1.8점 순위 23.8/12.9로 각각 감소폭이 가장 컸다. Mann-Whiteny를 통한 사후 검정 결과 실험1)의 튜브 각도 15˚/20˚와 실험2)의 튜브 각도가 5˚/10˚는 통계적으로 유의하였다.(p〈0.05) 결 론:DR wireless detector에 gird(ratio 10:1)를 사용한 abdomen upright 검사에서 cut-off 현상은 튜브각도가 양극과 음극방향에서 15˚이상 주어지거나 detector가 피사체의 관상면에서 5˚이상 oblique하게 기울어진 경우 발생한다. 튜브각도는 수직입사에서 ±15˚이상 주지 않고 detector는 피사체의 관상면에 oblique하게 놓지 않는다면 cut-off 현상을 방지 할 수 있으므로 임상에서 환자 피폭과 영상의 질적인 측면에서 고려해야 할 사항이다. Purpose:If the abdomen is upright in the mobile bed and the obese patient is in the DR wireless detector, the grid is used for the examination. In this case, the cut-off phenomenon may occur depending on the X-ray incident angle and the geometrical position of the detector, and the range of the optimum X-ray incident angle that can reduce the influence of the cut-off phenomenon is investigated. Materials and Methods:We used a parallel gird (ratio 10: 1) to the X - ray generator and the DR wireless detector and then reproduced the abdomen upright test using abdominal phantom. The tube voltage was 70kVp, the tube current was 20mAs, and the SID was 130cm. Experiment 1) The tube angle was increased by 5 ° in the direction of the cathode to 0 °, and it was changed to 30 °. The geometrical change of the detector was set 90 ° (vertical) to the transverse section of the phantom and inclined ± 10 ° and ± 20 ° back and forth . Experiment 2) The tube angle was increased by 5 ° in the direction of the cathode by 0 ° and changed to 15 °. The geometric change of the detector was set at 5 ° and 10 ° to the side of the phantom parallel to the coronal plane. Tube angles were applied to each detector according to the geometric change of the detector. The acquired images were measured by means of a visual evaluation using the Rickert scale of three radiologists and the mean and standard deviation of the signals in the same area of interest using the Image J program. Statistical analysis was performed using the Kruskal-wallis test and Mann-Whiteny and the corresponding sample t-test for statistical significance. Result:In the quantitative evaluation, the contrast- to-noise ratio of Experiment 1) was 11.29 / 10.62 / 10.27 / 9.34 / 6.74 / 4.61 when the tube angle was 0˚ / 5˚ / 10˚ / 15˚ / 20˚ / 3.63, respectively (p 〈0.05). Experiment 2) showed an average 9.37 / 8.19 / 6.73 / 6.29 when the tube angle was 0˚ / 5˚ / 10˚ / 15˚, but there was no statistically significant difference (p〉 0.05). In Experiment 1), the contrast- to-noise ratio was the greatest at a tube angle between 15 ° and 20 °. In the qualitative evaluation results, the average score of the respondents and the Kruskal-wallis test rank test were 4.5 points / 2.8 points and 67.9 / 37.2 points respectively when the tube angle was 15˚ / 20˚, and in the Experiment 2) The average decrease was 3.6 points / 1.8 points and 23.8 / 12.9 points respectively. After the posttest by Mann-Whiteny, the tube angle of 15˚ / 20˚ in Experiment 1) and the tube angle of 5˚ / 10˚ in Experiment 2) were statistically significant (p 〈0.05) Conclusion:In the abdomen upright test using gird (ratio 10: 1) on the DR wireless detector, the cutoff phenomenon was observed when the tube angle was more than 15 ° in the direction of the anode and cathode, or when the detector was obliquely inclined more than 5 ° in the coronal plane of the subject Occurs. If the tube angle is not more than ± 15 ° in vertical incidence and the detector is not obliquely placed on the coronal surface of the subject, it can prevent the cut-off phenomenon. Therefore, it should be considered in terms of patient exposure and quality of the image

      • 각형강관 기둥과 H-형강 보 접합부에 휨 거동에 관한 실험적 연구

        이장춘(Jang Chun Lee),이종석(Jong Seok Lee),박순규(Soon Kyu Park),김욱선(Uk Sun Kim),권영봉(Young Bong Kwon) 한국강구조학회 1994 韓國鋼構造學會誌 Vol.6 No.2

        It is normal practice to stiffen the End Plate Type connection for H-beam to S.H.S. column joint with diaphragm. The draw back of the diaphragm stiffened connection is that it need complicated work. Therefore, it becomes increasingly necessary to develop the End Plate Type connection without diaphragm in order to apply light weight building structures, This paper presents an experiments study for the End Plate Type connection for the H-beam to S.H.S. column joints. Two types of connection without diaphragm, (the one is the normal end plate connection and the other is the end plate connection stiffened with plug weld), have been tested to compare the characteristics of flexural behavior. The test results are compared with the results of numerical analysis by ABAQUS. As a result, the study show that, without the diaphram, the end plate connection could be properly stiffened by selecting the appropriate size of end plate and plug weld.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼