http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
KS F 2278을 적용한 대면적 시료 열관류율 시험 실측에 관한 연구
문재식 ( Moon Jae-sik ),이원균 ( Lee Won-gyun ),김영봉 ( Kim Young-bong ),조병영 ( Cho Byoung Young ),노상태 ( No Sang-tae ) 한국건축시공학회 2018 한국건축시공학회 학술발표대회 논문집 Vol.18 No.1
In Korea, The thermal resistance test of window sets is performed according to KS F 2278 standard, and is performed only on a specimen size of 2000 x 2000 (mm). In this study, a standard panel measuring 4000 x 3000 (mm) size was used to measure the heat flux in each part of the specimen, and to calculate the resistance to heat transfer And to seize whether the KS F 2278 standard is applicable to large Specimen.
Docker 기반 CI/CD 환경에서의 빌드캐시 최적화 방법
김경준(Kyeong-Jun Kim),문재식(Jae-Sik Moon),김문현(Moon-Hyun Kim),이준영(Jun-Young Lee),노서영(Seo-Young Noh) 한국정보과학회 2021 한국정보과학회 학술발표논문집 Vol.2021 No.6
최근 컨테이너 기술 기반의 오픈소스인 Docker가 많이 사용되고 있다. Docker는 개발한 소프트웨어를 이미지 형태로 빌드하는데, 이때 이미지 빌드시간을 최대한 줄이기 위해서 레이어 캐싱이라는 방법을 제공한다. 이는 이미지 빌드 시에 생성되는 빌드캐시를 이용하는 방식으로, 이미지 빌드시간을 많이 단축할 수 있다. 하지만 이미지의 특정 레이어에 변경이 일어나면 해당 변경된 레이어는 다시 빌드를 진행하게 되고, 변경 전의 레이어는 빌드캐시 상태로 로컬에 계속 남아있게 된다. 소프트웨어 개발이 진행되면서 레이어에 많은 변경이 생기게 되는데, 이로 인해 사용하지 않는 빌드캐시가 로컬에 계속 쌓이게 되어 스토리지가 낭비된다. 하지만 Docker에서의 빌드캐시를 자동으로 제거하는 방법을 제공하지 않는다. 따라서 로컬에 핫이는 빌드캐시를 제거 또는 교체하는 방법이 필요하다. 본 논문에서는 Docker의 빌드캐시를 CI/CD 파이프라인에서 자동으로 교체하는 방법을 제시한다. 이 방법을 통해 빌드캐시가 차지하는 스토리지 용량이 최대 Docker 이미지 크기의 두대 까지만 차지하도록 유지할 수 있다. 이와 동시에 빌드캐시를 최대한 활용해 CI과정 중에서 이미지를 빌드하는 시간을 단축시킬 수 있다.
패시브하우스 구축을 위한 건물외피시스템 단열성능 평가 기법 개발에 관한 연구
김영봉 ( Kim Young-bong ),문재식 ( Moon Jae-sik ),박동천 ( Park Dong-cheon ) 한국건축시공학회 2017 한국건축시공학회 학술발표대회 논문집 Vol.17 No.2
Due to the recent depletion of natural resources and global warming, a passive house type building exterior system has been developed and applied. For this purpose, we developed a building exterior thermal resistance performance evaluation system and verify the feasibility of this system for evaluation of passive house building system.
김생수,문재식,한상엽,최현호,박광채 조선대학교 생산기술연구소 1996 生産技術硏究 Vol.18 No.2
Personal Communications Services(PCS) is a low speed pedestrian mobile services capable of guaranteeing the communication with anybody, anytime and anywhere. In this paper, The purpose of microcell test is for the application tg microcell to the KMT PCS infrastructure. For the test. microcell equipments are established two places: on the close building and line-of-sight area. The test on a call processing, hand-off by speed, service coverage of the antenna type and the output power was carried out. The service coverage by output power was tested at 2.5mW and 25mW. As a result of test, the service coverage is about 300m when the output power is 2.5mW and the service coverage is about 800m when the output power is 25mW. The test also showed that the hand-off at the speed of 60km/h was possible on the service coverage of 300m and the hand-off at the speed of 90km/h was possible on the service coverage of 800m. The fading at the close building is so serious that we cannot call at 2.5mW, but we can call at 25mW.