http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김선훈,유승운 永同大學校 1999 硏究論叢 Vol.5 No.1
본 논문에서는 평판구조물의 동적해석에서 우수한 결과를 보여주는 개선된 유한요소를 제시하였다. 이 요소는 Mindlin평판이론에 의하여 수식화되었으며, Heterosis평판요소의 변위장에 2개의 비적합변위형을 추가함으로서 유도되었다. 본 논문에서 제시한 평판유한요소는 다른 요소들에 비해 신속한 수렴성을 보였으며, 아주 얇은 평 판문제에서도 요소의 형상에 관계없이 전단구속현상을 극복하였다. 또한 이 요소는 평판구조물의 동적해석에서도 신뢰할 만한 결과를 보여줌을 알 수 있었다. An improved finite element for dynamic analysis of plate structures is suggested in this paper. This element is based upon Mindlin plate concept. The displacement field of this element is also formulated by adding two non-conforming modes to rotational displacement components of a heterosis plate element. It is shown that the results obtained by the proposed element converged to analytical solutions very rapidly through numerical studies for various benchmark problems, and overcome the shear locking problem completely in very thin plate situation even for distorted meshes. It is also noted that the element is applicable to the dynamic analysis of plate structures.
김선훈 청운대학교 건설환경연구소 2015 청운대학교 건설환경연구소 논문집 Vol.10 No.2
Evaluation system for ultimate internal pressure capacity of nuclear reactor containment building is presented in this paper. This system includes high-performance degenerated plate and shell element as finite element library and adopts numerical modelling technique for unbonded tendon as well as bonded tendon in prestressed concrete structures. This system is constructed by connecting several in-house program to a commercial program DIANA, and then is capable of performing nonlinear analysis for ultimate pressure capacity of nuclear reactor containment building. Several typical numerical problems are carried out in order to show the reliability of this system. Finally a numerical study for evaluation of ultimate internal capacity of prestressed concrete containment vessel (PCCV) is presented. 본 논문에서는 원자로 격납건물의 극한내압능력의 평가시스템을 구축하여 제시하였다. 이 시스템에서는 고성능 평판 및 쉘 유한요소를 요소 라이브러리로 사용하고, 비부착식 텐돈과 부착식 텐돈의 거동을 정확하게 묘사할 수 있는 모델링방법을 포함하고 있다. 이러한 기능을 프로그래밍하고 범용 구조해석프로그램 DIANA에 접목시켜 원자로 격납건물의 비선형해석은 물론이고 내압능력 평가가 가능하다. 몇개의 대표적인 수치예제 해석을 통하여 이 시스템의 신뢰도를 검증하였다. 본 논문에서 제안한 내압능력평가 시스템을 사용하여 PCCV 격납건물의 구조해석을 수행하고 내압능력평가 결과를 제시하였다.
생산 능력과 연동되는 제조공기를 고려한 생산계획 최적화 모형
김선훈,이영훈 한국경영과학회 2009 한국경영과학회 학술대회논문집 Vol.2009 No.5
반도체 산업은 고객 만족(혹은 수요 충족)이 생산라인의 중요한 지표 중 하나로서, 대내적으로는 생산의 효율성과 제조공기의 관리가 중요한 지표 중 하나라고 할 수 있다. 이를 위하여 생산 라인에 적절한 수준의 재공을 유지시켜 주는 것이 매우 중요하다. 이에 본 논문에서는 생산라인의 적정재공을 계산한 후 이를 모델에 반영하는 기존의 생산계획 수립 방법과는 달리 제조공기와 수요 정보를 이용하여 모델 안에서 적정재공을 계산함으로써 수요 충족과 적정재공 유지를 동시에 고려하는 최적화 모형을 제안한다. 다양한 환경 하에서의 실험을 통해 생산량, 제조공기, 수요 충족 등의 평가 지표에 대해 기존 모형과 비교 평가하였다.
생산 능력과 연동되는 제조공기를 고려한 생산계획 최적화 모형
김선훈,이영훈 대한산업공학회 2009 대한산업공학회 춘계학술대회논문집 Vol.2009 No.5
반도체 산업은 고객 만족(혹은 수요 충족)이 생산라인의 중요한 지표 중 하나로서, 대내적으로는 생산의 효율성과 제조공기의 관리가 중요한 지표 중 하나라고 할 수 있다. 이를 위하여 생산 라인에 적절한 수준의 재공을 유지시켜 주는 것이 매우 중요하다. 이에 본 논문에서는 생산라인의 적정재공을 계산한 후 이를 모델에 반영하는 기존의 생산계획 수립 방법과는 달리 제조공기와 수요 정보를 이용하여 모델 안에서 적정재공을 계산함으로써 수요 충족과 적정재공 유지를 동시에 고려하는 최적화 모형을 제안한다. 다양한 환경 하에서의 실험을 통해 생산량, 제조공기, 수요 충족 등의 평가 지표에 대해 기존 모형과 비교 평가하였다.
강성행렬의 수정적분차수와 선형조합에 의한 평면유한요소의 개선
김선훈 청운대학교 건설환경연구소 2012 청운대학교 건설환경연구소 논문집 Vol.7 No.1
In this paper the efficient finite element for stress analysis of plane stress/strain problems is proposed. This element is achieved by adding the bubble-mode function to 8-node element. The stiffness matrix of the element is calculated by using modified numerical integration order. And then linear combination of stiffness matrix to avoid spurious zero energy mode is performed. In order to demonstrate the performance of this element numerical tests for various verification problems are carried out. The results of numerical tests show accuracy and reliability of the element presented in this paper. 본 논문에서는 평면응력/변형도 문제의 응력해석에 효과적인 결과를 보여주는 개선된 유한요소를제안하였다. 이 요소의 강성행렬은 8절점 요소의 변위형상에 Bubble 모드를 추가함으로써 구할 수 있었다. 그리고 요소의 강성행렬 계산시 정상적분과 감차적분을 혼합하여 적용한 수정된 적분차수를 사용하였다. 또한 정상적분에 의한 강성행렬과 감차적분에 의한 강성행렬의 선형조합을 통하여 의사 영에너지 모드의 발생을 피할 수 있었다. 요소의 신뢰성과 정확성을 입증하기위해 여러 가지 예제에 대하여 수치검증작업이 수행되었다. 요소의 수치시험 결과 본 논문에서 제안된 요소는 비교대상의 요소들에 비하여 비교적 양호한 결과를 보여주었다.
비선형동적해석을 통한 건식 기계적이음을 갖는 프리캐스트 모멘트 골조의 동등성 평가
김선훈,이원준,이득행 한국지진공학회 2024 한국지진공학회논문집 Vol.28 No.2
This study presents code-compliant seismic details by addressing dry mechanical splices for precast concrete (PC) beam-column connections in the ACI 318-19 code. To this end, critical observations of previous test results on precast beam-column connection specimens with the proposed seismic detail are briefly reported in this study, along with a typical reinforced concrete (RC) monolithic connection. On this basis, nonlinear dynamic models were developed to verify seismic responses of the PC emulative moment-resisting frame systems. As the current design code allows only the emulative design approach, this study aims at identifying the seismic performances of PC moment frame systems depending on their emulative levels, for which two extreme cases were intentionally chosen as the non-emulative (unbonded self-centering with marginal energy dissipation) and fully-emulative connection details. Their corresponding hysteresis models were set by using commercial finite element analysis software. According to the current seismic design provisions, a typical five-story building was designed as a target PC building. Subsequently, nonlinear dynamic time history analyses were performed with seven ground motions to investigate the impact of emulation level or hysteresis models (i.e., energy dissipation performance) on system responses between the emulative and non-emulative PC moment frames. The analytical results showed that both the base shear and story drift ratio were substantially reduced in the emulative system compared to that of the non-emulative one, and it indicates the importance of the code-compliant (i.e., emulative) connection details on the seismic performance of the precast building.
CANDU형 원자로 격납건물의 극한내압능력 평가에 관한 연구
김선훈,Kim, Sun-Hoon 한국전산구조공학회 2011 한국전산구조공학회논문집 Vol.24 No.3
원자로 격납건물은 원자력발전소에서 발생가능한 모든 비상사태에 대한 최후의 방벽 역할을 하고 있다. 따라서 사고발생시 원자로 격납건물의 극한능력을 판단하는 것은 매우 중요하다. 대표적인 고려사항 가운데 하나인 LOCA사고 발생시 CANDU형 원자로 격납건물의 극한능력을 파악하기 위해서는 구조적 안전성 평가를 위한 구조해석이 필요하다. CANDU형 원자로 격납건물은 돔과 원통형벽체로 구성된 프리스트레스 콘크리트 쉘 구조물로서 부착식 텐돈을 사용하고 있다. 본 논문에서는 극한내압능력의 평가를 위하여 3차원 구조해석시스템을 사용한 프리스트레스 콘크리트 격납건물의 비선형해석을 수행하였다. Nuclear containment building is the last barrier for being secure from any nuclear power plant accident. Therefore, it is very important to understand the ultimate capacity of nuclear containment building to loads associated with severe accidents. LOCA (loss of coolant accident) is considered as the basic accidental load and CANDU-type containment building is considered as a target structure in order to conduct the numerical analysis for the structural safety of a containment building. The CANDU-type containment building is a prestressed concrete shell structure which has the dome and the cylindrical wall and is reinforced with bonded tendons. In this paper, the evaluation of ultimate internal pressure capacity was carried out by nonlinear analysis of a prestressed concrete containment building using 3-dimensional structural analysis system.
김선훈 청운대학교 건설환경연구소 2013 청운대학교 건설환경연구소 논문집 Vol.8 No.1
In this paper an improved finite element for stress analysis of axisymmetric problems is proposed. The displacement field of this element is formulated by adding the bubble-mode function to displacement mode of the quadratic finite element. Modified numerical integration technique and linear combination of stiffness matrix is applied to calculate the stiffness matrix of the element in order to avoid spurious zero energy mode. Numerical tests for various verification problems are carried out. The results of numerical tests show accuracy and reliability of the element presented in this paper. Ultimate capacity of the containment structure is also investigated using this axisymmetric element. 본 논문에서는 축대칭 구조물의 응력해석을 위한 개선된 유한요소를 제안하였다. 이 요소의 강성행렬은 이차유한요소의 변위형상에 Bubble 모드를 추가함으로써 구할 수 있었다. 그리고 요소의 강성행렬 계산시 수정된 적분차수를 사용하고 강성행렬의 선형조합을 통하여 의사 영 에너지 모드의 발생을 피하였다. 요소의 신뢰성과 정확성을 입증하기위해 여러 가지 예제에 대하여 수치검증작업이 수행되었다. 요소의 수치시험 결과 본 논문에서 제안된 요소는 비교대상의 요소들에 비하여 비교적 양호한 결과를 보여주었다. 또한 이 요소의 적용성을 보기 위하여 원자력발전소 격납구조물의 극한능력을 검토해 보았다.
프리스트레스 콘크리트 격납구조물의 강재라이너 플레이트 유한요소 모델링기법
김선훈 청운대학교 건설환경연구소 2011 청운대학교 건설환경연구소 논문집 Vol.6 No.1
In order to determine a realistic lower bound of a typical reactor containment structural capacity for internal pressure, modelling techniques and analytical investigation to predict its non-linear behavior up to ultimate capacity are required. Especially, the steel liner of PWR-type reactor containment played the important role of a leaktight contour preventing the possible releases of radioactive substances beyond the boundaries of the containment building. Therefore, finite element modelling techniques of steel liner for structural analysis of PWR-type prestressed concrete containment vessel (PCCV) will be suggested in this study. 원자력발전소 격납구조물의 내압에 대한 구조적 저항력의 최소치를 결정하기 위해서는 극한능력의 비선형영역까지의 거동을 정확하게 파악할 수 있는 모델링방법과 해석적 분석작업이 필요하다. 특히 경수로형 원자로 격납구조물의 강재라이너는 방사성물질이 격납건물 주변영역으로 누출되는 것을 방어하는 매우 중요한 역할을 한다. 따라서 본 논문에서는 경수로형 프리스트레스 콘크리트 격납구조물(Prestressed Concrete Containment Vessel; PCCV)의 구조해석시 강재 라이너플레이트의 유한요소모델링기법에 대해 제시하였다.