        Buckling resistance, bending stiffness, and torsional resistance of various instruments for canal exploration and glide path preparation

        곽상원,하정홍,이우철,김성교,김현철 대한치과보존학회 2014 Restorative Dentistry & Endodontics Vol.39 No.4

        Objectives: This study compared the mechanical properties of various instruments for canal exploration and glide-path preparations. Materials and Methods: The buckling resistance, bending stiffness, ultimate torsional strength, and fracture angle under torsional load were compared for C+ file (CP, Dentsply Maillefer), M access K-file (MA, Dentsply Maillefer), Mani K-file (MN, Mani), and NiTiFlex K-file (NT, Dentsply Maillefer). The files of ISO size #15 and a shaft length of 25 mm were selected. For measuring buckling resistance (n = 10), the files were loaded in the axial direction of the shaft, and the maximum load was measured during the files’ deflection. The files (n = 10) were fixed at 3 mm from the tip and then bent 45° with respect to their long axis, while the bending force was recorded by a load cell. For measuring the torsional properties, the files (n = 10) were also fixed at 3 mm, and clockwise rotations (2 rpm) were applied to the files in a straight state. The torsional load and the distortion angle were recorded until the files succumbed to the torque. Results: The CP was shown to require the highest load to buckle and bend the files, and the NT showed the least. While MA and MN showed similar buckling resistances, MN showed higher bending stiffness than MA. The NT had the lowest bending stiffness and ultimate torsional strength (p < 0.05). Conclusions: The tested instruments showed different mechanical properties depending on the evaluated parameters. CP and NT files were revealed to be the stiffest and the most flexible instruments, respectively.

      • KCI등재

        Effect of surface treatment on the mechanical properties of nickel-titanium files with a similar cross-section

        곽상원,이주영,구혜진,김현철 대한치과보존학회 2017 Restorative Dentistry & Endodontics Vol.42 No.3

        Objectives: The aim of this study was to compare the mechanical properties of various nickel-titanium (NiTi) files with similar tapers and cross-sectional areas depending on whether they were surface-treated. Materials and Methods: Three NiTi file systems with a similar convex triangular cross-section and the same ISO #25 tip size were selected for this study: G6 (G6), ProTaper Universal (PTU), and Dia-PT (DPT). To test torsional resistance, 5 mm of the straightened file's tip was fixed between polycarbonate blocks (n = 15/group) and continuous clockwise rotation until fracture was conducted using a customized device. To evaluate cyclic fatigue resistance, files were rotated in an artificial curved canal until fracture in a dynamic mode (n = 15/group). The torsional data were analyzed using 1-way analysis of variance and the Tukey post-hoc comparison test, while the cyclic fatigue data were analyzed using the Mann-Whitney U test at a significance level of 95%. Results: PTU showed significantly greater toughness, followed by DPT and G6 (p < 0.05). G6 showed the lowest resistance in ultimate torsional strength, while it showed a higher fracture angle than the other files (p < 0.05). In the cyclic fatigue test, DPT showed a significantly higher number of cycles to failure than PTU or G6 (p < 0.05). Conclusions: Within the limitations of this study, it can be concluded that the torsional resistance of NiTi files was affected by the cross-sectional area, while the cyclic fatigue resistance of NiTi files was influenced by the surface treatment.

      • KCI등재

        중등학교 과학 교사의 밀도에 관한 내용교수지식 수준과 그에 따른 내용 표상의 구성 요소별 특징

        곽상원,최병순,Kwak, Sang-Won,Choi, Byung-Soon 대한화학회 2012 대한화학회지 Vol.56 No.1

        The purposes of this study were to evaluate the level of PCK which middle school science teachers have on the concept of density and to analyze the characteristics of science teachers' content representation on the concept of density by their PCK level. For that purpose, 20 science teachers were selected and asked to answer the questionnaire on the eight aspects of CoRe. Results of this study indicated that the science teachers' PCK levels were low in general and evaluated as below average. The differences among the characteristics of science teachers' content representation by their PCK level were high in seven aspects of CoRe but the one aspect of the understanding of learner's preconception. These differences were analyzed and the patterns shown by the science teachers in eight aspects of CoRe were drawn in this study. It was also found that the characteristics drawn in eight aspects of content representation shown by the teachers whose PCK level was medium were close to those whose PCK level was low rather than high in most aspects of CoRe. 이 연구에서는 중등학교 과학 교사 20명을 대상으로 밀도에 대한 내용 표상을 조사하여 각 교사의 밀도 수업과 관련된 내용교수지식 수준을 판단하고, 그에 따라 내용 표상의 구성 요소별로 어떤 특징이 있는지를 분석하였다. 연구결과, 과학 교사들의 내용교수지식 수준은 전반적으로 보통 수준으로 판명되었다. 교사들의 내용교수지식 수준에 따라 나타나는 내용 표상의 구성 요소별 특징은 '학습자의 선개념에 대한 이해'를 제외한 7개의 구성 요소에서 차이가 크게 나타남을 알 수 있었으며, 이 연구에서는 그 차이를 구성 요소별로 분석하고, 그 특징을 추출하였다. 또한, 내용교수지식 수준이 중간인 교사들에게서 나타난 내용 표상의 구성 요소별 특징은 내용교수지식 수준이 높은 교사들 보다는 낮은 교사들과 대부분의 구성 요소에서 비슷한 것으로 밝혀졌다.

      • KCI등재

        Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study

        곽상원,문영미,유연지,백승호,이우철,김현철 대한치과보존학회 2014 Restorative Dentistry & Endodontics Vol.39 No.4

        Objectives: The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods: The apical 3 mm of each root was resected, and rootend preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using twoway analysis of variance and a Mann-Whitney test. Results: There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions: Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.

      • KCI등재

        Preference of undergraduate students after first experience on nickel-titanium endodontic instruments

        곽상원,Gary Shun Pan Cheung,하정홍,김성교,이효진,김현철 대한치과보존학회 2016 Restorative Dentistry & Endodontics Vol.41 No.3

        Objectives: This study aimed to compare two nickel-titanium systems (rotary vs. reciprocating) for their acceptance by undergraduate students who experienced nickeltitanium (NiTi) instruments for the first time. Materials and Methods: Eighty-one sophomore dental students were first taught on manual root canal preparation with stainless-steel files. After that, they were instructed on the use of ProTaper Universal system (PTU, Dentsply Maillefer), then the WaveOne (WO, Dentsply Maillefer). They practiced with each system on 2 extracted molars, before using those files to shape the buccal or mesial canals of additional first molars. A questionnaire was completed after using each file system, seeking students’ perception about ‘Ease of use’, ‘Flexibility’, ‘Cutting-efficiency’, ‘Screwing-effect’, ‘Feeling-safety’, and ‘Instrumentation-time’ of the NiTi files, relative to stainless-steel instrumentation, on a 5-point Likert-type scale. They were also requested to indicate their preference between the two systems. Data was compared between groups using t-test, and with Chi-square test for correlation of each perception value with the preferred choice (p = 0.05). Results: Among the 81 students, 55 indicated their preferred file system as WO and 22 as PTU. All scores were greater than 4 (better) for both systems, compared with stainless-steel files, except for ‘Screwing-effect’ for PTU. The scores for WO in the categories of ‘Flexibility’, ‘Screwingeffect’, and ‘Feeling-safety’ were significantly higher scores than those of PTU. A significant association between the ‘Screwing-effect’ and students’ preference for WO was observed. Conclusions: Novice operators preferred nickel-titanium instruments to stainless-steel, and majority of them opted for reciprocating file instead of continuous rotating system.

      • KCI등재

        Endocem MTA와 ProRoot MTA를 이용한 부분치수절단술 후 통증 발생에 관한 임상 연구

        곽상원,김현철 대한치과의사협회 2018 대한치과의사협회지 Vol.57 No.1

        Objectives: This study aimed to compare the postoperative pain and clinical performance after partial pulpotomy by using ProRoot MTA and Endocem MTA. Materials and Methods: Twenty-eight teeth requiring partial pulpotomy due to deep dental caries or traumatic injury were included in this study. After 2mm removal of exposed pulp and bleeding control, the ProRoot MTA or Endocem MTA was randomly adjusted to the exposed site. 1, 2, 4, and 12 weeks after the final restoration, the patients were recalled to check the postoperative pain or another unfavorable signs. Pearson’s chi-square test was used for statistical analysis to evaluate any differences among tested materials. Results: 3 of 28 teeth showed postoperative pain and cold positive during followup period (10.7%). There were no statistically differences in pain occurrence between two tested materials (P > 0.05). Conclusions: In the limitations of this study, partial pulpotomy by using Endocem MTA showed the advantages of short setting time and lower postoperative pain incidence, allowing one visit treatment.

      • KCI등재

        니켈티타늄 전동 파일의 기계적 특성 비교: Aurum Blue vs. Aurum Pro

        곽상원,하정홍,안상미,김현철 대한치과의사협회 2019 대한치과의사협회지 Vol.57 No.11

        AIM: The purpose of this study was to evaluate and compare the torsional fracture resistances, cyclic fatigue resistance, and bending stiffness of two nickel-titanium (NiTi) rotary instruments made of different heat-treated alloy: Aurum Blue (heat-treated) and Aurum Pro (conventional). Methods: Forty-five Aurum Blue and Aurum Pro NiTi files were selected for the three mechanical tests (n=15). For the torsional resistance test, 3 mm file tip was fixed and the shaft was driven clockwise at 2 rpm until fracture occurred by using a customized device. Cyclic fatigue resistance was evaluated by rotating instruments in artificial canal with dynamic mode. Bending stiffness was tested by observation of the bending moment on attaining a 45° bend. The results were analyzed by student-t tests at a significance level of 95%. The fractured surface of each groups were examined under a scanning electron microscope (SEM). Results: Aurum Blue showed significantly higher toughness, ultimate strength, distortion angle, and number of cycles to failure than those of Aurum Pro (p < 0.05). However, Aurum Blue and Aurum Pro did not differ significantly in terms of bending stiffness. SEM showed typical topographic appearances of the cyclic fatigue and torsional fracture. Conclusions: Under the limitations of this study, heat-treated instruments showed higher flexibility and fracture resistances than conventional NiTi instruments.

      • KCI등재

        근단부 성형 크기에 따른 다양한 전동 니켈티타늄 파일의 중심 변위율 및 만곡도 감소 비교

        곽상원(Sang-Won Kwak),박정길(Jeong-Kil Park),허복(Bock Hur),김현철(Hyeon-Cheol Kim) 대한치과의사협회 2010 대한치과의사협회지 Vol.48 No.7

        The purpose of this study was to compare the centering ratio and reduction of canal curvature according to the preparation sizes of #30, #40 and #50 using three rotary NiTi instruments which have different shaft tapers. Seventy-two simulated root canals in clear resin blocks (Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland) were divided as following 3 groups according to the file system; the 24 canal blocks prepared with each of ProTaper Universal system (Group P), LightSpeed eXtra system (Group L), and K3 (Group K). The pre- and post-instrumented root canals were scanned and superimposed to evaluate and calculate the centering ratio and reduction of canal curvature. Mean scores of each group were statistically analyzed using one-way ANOVA and Duncan’s multiple range test for post-hoc comparison. The results were as followings: 1. Group L showed better centering ratio, followed by K and P. And all experimental groups generally showed increasing tendency of centering ratio as the apical size was increasing from #30 to #50, except at 1㎜ level of group P where showed reducing tendency of centering ratio. The smaller the ratio, the better the instrument remained centered in the canal. 2. Group P showed more decrease of canal curvature at all apical shaping size (p<0.05) Under the conditions of this study, the shaft design could affect the quality of canal shaping and the smooth taperless flexible (LightSpeed) shaft design was capable of preparing canals with good morphological characteristics in curved canals.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼