강인석,김남진,김종보 한국에너지학회 2001 에너지공학 Vol.10 No.4
충진농도, 냉매 팽창밸브 개도, 그리고 약용액의 유량 변화에 따른 벤치타입 암모니아-물 흡수식 열교환 사이클에 대한 실험을 수행한 결과 시스템의 충진농도가 증가할수록 냉방능력이 증가하였으며, 최적의 충진농도가 존재함을 알았다. 그리고 냉매 팽창 밸브의 개도는 응축기 출구의 직접적인 영향을 주고 있으며 최적의 과냉도가 0~4$^{\circ}C$임을 알았다. 또한 약용액의 유량이 증가시킬수록 증발압력과 강용액의 농도가 즐어들었으며, 냉방능력과 COP가 최대가 되는 최적의 약용액 유량이 존재하였다. A bench type ammonia-water absorber heat exchange cycle was tested by varying the system charging concentration, refrigerating valve opening and weak solution flow rate. It was observed that the cooling capacity was increased as the system charging concentration was increased. Optimum system charging concentration was found for the coolong capacity of the system. The opening rate of refrigerant expansion valve had a direct influence on the refrigerant sub-cooling at the condenser outlet. Optimum sub-cooling was found to be 0~4$^{\circ}C$. As the weak solution flow rate increased the concentration of strong solution and the evaporating pressure decreased. There existed a optimum weak solution flow rate which maximized the cooling capacity and COP.
강인석,김남진,김종보 대한설비공학회 2001 설비공학 논문집 Vol.13 No.7
Small capacity gas absorption systems for cooling and heating have been favorably considered to reduce the seasonal imbalance of electrical loads and LNG consumption recently. A multifunctional plate-fin heat exchanger was adopted as an absorber and the performance was tested and analyzed to reduce the size and weight of the absorption heat pump. The test was performed using breadboard type ammonia absorption machine. The performance was compared with the plate type absorber and there was little difference in heat and mass transfer characteristics. The heat and mass transfer performance was a function of poor solution and vapor flow rates and the mass transfer was dependent on vapor flow rate more than heat transfer.
건설분야 전자매뉴얼의 필요성 및 특성분석을 통한 실무적용성 연구
강인석,정원명,곽중민,Kang, Leen-Seok,Jung, Won-Myung,Kwak, Joong-Min 한국건설관리학회 2005 건설관리 : 한국건설관리학회 학회지 Vol.6 No.1
건설분야 전자매뉴얼은 기존에 서술적 문서형태로 작성되어온 시공법, 유지관리절차 등에 관련된 시방규정, 지침서들이 시각화를 위한 멀티 미디어 기능과 통합연계정보 제공기능을 갖는 전자적 형태로 구성된 것을 의미한다. 이러한 전자적 개념의 건설전자매뉴얼은 지침 규정의 전자화는 물론이고, 공사관리자의 이해도 증진을 위해 해당 규정에 관련된 3D동영상 화면과 가상현실, 시공이력사진 정보들을 연계해서 제공해 주는 종합 정보시스템 개념을 갖고 있다. 현재 시방정보, 관련법규 등의 건설분야 각종 지침들은 전자화를 위한 표준적 인 규칙 이 없이 일반적 인 문서형 태로 작성되고 있으므로, 관련정보의 체계적인 축적 및 공유가 어렵고 효과적 인 시설물의 시공 및 유지관리에 장애요인이 되고 있다. 본 연구에서는 기존 건설분야 정보화 체계와 비교하여 전자매뉴얼의 필요성과 타 분야 전자매뉴얼대비 건설전자매뉴얼의 특성을 분석하여 건설분야에 적합한 구성전략을 제시함으로써, 건설분야 전자매뉴얼의 활용도를 인식시키는데 연구목적이 있다. 이를 위하여 본 연구에서는 유지관리업무 전자매뉴얼 시안을 포함하는 시설물 재해관리용 전자매뉴얼의 적용성을 가상적으로 구성하여 검증하고 있다. Interactive electronic technical manual(IETM) for construction projects means an electronic tool that regulations and specifications related to construction method or maintenance process ale described by electronic book type. It has a meaning of integrated information system that includes virtual reality(VR), 3D animation and image contents for representing real construction information so that user can easily understand the construction situation and maintenance process. The basic information and technical manuals of construction facilities are being written as paper documents in our construction industry. As the result, the information management in the maintenance phase of construction projects is inefficient, and maintenance cost is being increased. This study attempts to improve the lack of understanding about construction IETM through the analysis of necessity and unique function of construction IETM comparing with the IETMS in other industry, Finally, this study shows a scenario of construction IErM for mitigating natural disaster of construction facilities to verify applicability of IETM.
병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구
강인석,최동규,김택영 대한설비공학회 2004 설비공학 논문집 Vol.16 No.11
Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as -30℃, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.