RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Distributed Fault Detection and Isolation Scheme for Abrupt and Incipient Faults in a Class of Nonlinear Systems

        Zhiqiang Zheng,Yongxin Liu,Haiwen Yuan,Qiusheng Wang 제어·로봇·시스템학회 2012 International Journal of Control, Automation, and Vol.10 No.3

        This note developed a distributed fault detection and isolation scheme for a class of large-scale systems in discrete-time framework. The unstructured modeling uncertainty and abrupt and incipient faults are considered in this scheme. By using overlapping decompositions, the large-scale system is decomposed into a set of subsystems which are monitored by a network of local fault detectors (LFDs) and local fault isolation estimators (LFIEs). Specially, the LFIEs, corresponding the faults af-fecting the common components among different subsystems, may reach a cooperative (or consensus) isolation decision, based on the fact that they can exchange some knowledge about the local information of system by suitable communication links. As a result, for these LFIEs, the capability of isolating faults may be improved. Moreover, the derivation of rigorous analytical results for the detectability and isolability properties of the proposed scheme is given. Simulation results are provided to show the effectiveness of the presented scheme.

      • KCI등재

        SIMULATION-BASED DESIGN METHOD FOR ROOM AIR CONDITIONER WITH SMALLER DIAMETER COPPER TUBES

        Guoliang Ding,TAO REN,YONGXIN ZHENG,YIFENG GAO,JI SONG 대한설비공학회 2012 International Journal Of Air-Conditioning and Refr Vol.20 No.3

        Promoting the use of smaller diameter tube in room air conditioner is bene¯cial to reduce copper consumption and refrigerant charge, but may cause reduction of air conditioner performance, so a design method is needed. This paper presents a simulation-based design method for air conditioner with smaller diameter tube. The new method combines heat exchanger simulator and knowledge-based evolution method optimizer for designing air conditioner heat exchanger with smaller diameter tube. The simulation-based design method is illustrated in detail by an air conditioner of replacing 7mm tube indoor unit heat exchanger and 9.52mm tube outdoor unit heat exchanger with 5mm tube. Case study shows that the cost of the designed air conditioner with 5mm copper tube is 17.3% lower than that of the original one while the performance deviation between these two air conditioners is less than 0.7%.

      • SCIESCOPUSKCI등재

        BSA‑carbon dots a promising “off–on” fluorescence probe for detecting glyphosate residues in agricultural products

        Qian Wang,Miao Wang,Lufei Zheng,Yongxin She,Jing Wang,Minghong Jia,A. M. Abd El‑Aty 한국탄소학회 2023 Carbon Letters Vol.33 No.7

        The widespread and extensive use of glyphosate in agriculture has raised concerns about its potential impact on the quality and safety of agricultural products. Conventional detection methods require long analysis times, making them impractical for the rapid detection of large quantities of samples. Therefore, developing a fast and simple detection system for glyphosate pesticide residues is urgent. In this study, the development of a facile fluorescence probe synthesized using a simple one-pot hydrothermal method for the determination of glyphosate is an important step toward addressing the need for a fast and simple detection system. The present sensor was created using bovine serum albumin (BSA) as a precursor, and the sensor operates by producing an “off–on” fluorescent signal. The bovine albumin-derived BSA-CDs emitted light yellow fluorescence, but this fluorescence was quenched (or suppressed) by the presence of Cu2+ ions. However, the fluorescence can be restored by the presence of glyphosate, which interacts with the Cu2+ ions to form a complex and release the BSACDs from suppression. The functional groups in glyphosate can capture Cu2+ and break the BSA-CDs/Cu2+ combinatorial system. The BSA-CDs/Cu2+ fluorescence quenching system had good selectivity for glyphosate. The detection limit of the BSA-CD/Cu2+ fluorescence sensor was 0.05 μg/mL. This developed method was utilized to successfully detect glyphosate in Chinese wheat. The average recoveries ranged from 98.9 to 100.7%, with a relative standard deviation < 3.0%, showing good prospects for practical applicability.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼