http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Geng, Chuan-Ying,Liu, Nian,Yang, Guang-Zhong,Liu, Ai-Jun,Leng, Yun,Wang, Hui-Juan,Li, Li-Hong,Wu, Yin,Li, Yan-Chen,Chen, Wen-Ming Asian Pacific Journal of Cancer Prevention 2012 Asian Pacific journal of cancer prevention Vol.13 No.11
At present, multiple myeloma (MM) remains an incurable disease and cologenic cells may be responsible for disease relapse. It has been proposed that CD20+/CD138- NCI-H929 cells could be hallmarks of MM clonogenic cells. Here, the immunology phenotype of NCI-H929 cells is described. Only a small population of CD20+/CD138- cells (<1%) was found in the NCI-H929 cell line, but CD20+/CD138- cells were not detected. We found that CD20+/CD138+ cells were able to exhibit cologenic capacity by colony formation assay and continuous passage culture. Proteins were analyzed by 1D-SDS-PAGE and TMT based quantitative differential liquid chromatography tandem mass spectrometry (LC-MS/MS). 1,082 non-redundant proteins were identified, 658 of which were differentially expressed with at least a 1.5-fold difference. 205 proteins in CD20+ cells were expressed at higher levels and 453 proteins were at lower levels compared with CD20- cells. Most proteins had catalytic and binding activity and mainly participated in metabolic processes, cell communication and molecular transport. These results proved that there are different biological features and protein expression profile between CD20+ and CD20- cells in the NCI-H929 cell line.
An Improved Active Damping Method with Capacitor Current Feedback
Geng, Yi-Wen,Qi, Ya-Wen,Liu, Hai-Wei,Guo, Fei,Zheng, Peng-Fei,Li, Yong-Gang,Dong, Wen-Ming The Korean Institute of Power Electronics 2018 JOURNAL OF POWER ELECTRONICS Vol.18 No.2
Proportional capacitor current feedback active damping (CCFAD) has a limited valid damping region in the discrete time domain as (0, $f_s/6$. However, the resonance frequency ($f_r$) of an LCL-type filter is usually designed to be less than half the sampling frequency ($f_s$) with the symmetry regular sampling method. Therefore, ($f_s/6$, $f_s/2$) becomes an invalid damping region. This paper proposes an improved CCFAD method to extend the valid damping region from (0, $f_s/6$ to (0, $f_s/2$), which covers all of the possible resonance frequencies in the design procedure. The full-valid damping region is obtained and the stability margin of the system is analyzed in the discrete time domain with the Nyquist criterion. Results show that the system can operate stably with the proposed CCFAD method when the resonance frequency is in the region (0, $f_s/2$). The performances at the steady and dynamic state are enhanced by the selected feedback coefficient H and controller gain $K_p$. Finally, the feasibility and effectiveness of the proposed CCFAD method are verified by simulation and experimental results.
An Improved Active Damping Method with Capacitor Current Feedback
Yi-Wen Geng,Ya-Wen Qi,Hai-Wei Liu,Fei Guo,Peng-Fei Zheng,Yong-Gang Li,Wen-Ming Dong 전력전자학회 2018 JOURNAL OF POWER ELECTRONICS Vol.18 No.2
Proportional capacitor current feedback active damping (CCFAD) has a limited valid damping region in the discrete time domain as (0, fs/6). However, the resonance frequency (fr) of an LCL-type filter is usually designed to be less than half the sampling frequency (fs) with the symmetry regular sampling method. Therefore, (fs/6, fs/2) becomes an invalid damping region. This paper proposes an improved CCFAD method to extend the valid damping region from (0, fs/6) to (0, fs/2), which covers all of the possible resonance frequencies in the design procedure. The full-valid damping region is obtained and the stability margin of the system is analyzed in the discrete time domain with the Nyquist criterion. Results show that the system can operate stably with the proposed CCFAD method when the resonance frequency is in the region (0, fs/2). The performances at the steady and dynamic state are enhanced by the selected feedback coefficient H and controller gain Kp. Finally, the feasibility and effectiveness of the proposed CCFAD method are verified by simulation and experimental results.
Stability Analysis of Grid-Connected Inverters with an LCL Filter Considering Grid Impedance
Li, Xiao-Qiang,Wu, Xiao-Jie,Geng, Yi-Wen,Zhang, Qi The Korean Institute of Power Electronics 2013 JOURNAL OF POWER ELECTRONICS Vol.13 No.5
Under high grid impedance conditions, it is difficult to guarantee the stability of grid-connected inverters with an LCL filter designed based on ideal grid conditions. In this paper, the theoretical basis for output impedance calculation is introduced. Based on the small-signal model, the d-d channel closed-loop output impedance models adopting the converter-side current control method and the grid-side current control method are derived, respectively. Specifically, this paper shows how to simplify the stability analysis which is usually complemented based on the generalized Nyquist stability criterion (GNC). The stability of each current-controlled grid-connected system is analyzed via the proposed simplified method. Moreover, the influence of the LCL parameters on the stability margin of grid-connected inverter controlled with converter-side current is studied. It is shown that the stability of grid-connected systems is fully determined by the d-d channel output admittance of the grid-connected inverter and the inductive component of the grid impedance. Experimental results validate the proposed theoretical stability analysis.
Li-jun Liang,Chen-xi Hu,Yi-xuan Wen,Xiao-wei Geng,Ting Chen,Guo-qing Gu,Lei Wang,You-you Xia,Yong Liu,Jia-yan Fei,Jie Dong,Feng-hua Zhao,Yiliyar Ahongjiang,Kai-yuan Hui,Xiao-dong Jiang 대한암학회 2020 Cancer Research and Treatment Vol.52 No.2
Purpose This study aimed to investigate the potential systemic antitumor effects of stereotactic ablative radiotherapy (SABR) and apatinib (a novel vascular endothelial growth factor receptor 2 inhibitor) via reversing the immunosuppressive tumor microenvironment for lung carcinoma. Materials and Methods Lewis lung cancer cells were injected into C57BL/6 mice in the left hindlimb (primary tumor; irradiated) and in the right flank (secondary tumor; nonirradiated). When both tumors grew to the touchable size, mice were randomly divided into eight treatment groups. These groups received normal saline or three distinct doses of apatinib (50 mg/kg, 150 mg/kg, and 200 mg/kg) daily for 7 days, in combination with a single dose of 15 Gy radiotherapy or not to the primary tumor. The further tumor growth/regression of mice were followed and observed. Results For the single 15 Gy modality, tumor growth delay could only be observed at the primary tumor. When combining SABR and apatinib 200 mg/kg, significant retardation of both primary and secondary tumor growth could be observed, indicated an abscopal effect was induced. Mechanism analysis suggested that programmed death-ligand 1 expression increased with SABR was counteract by additional apatinib therapy. Furthermore, when apatinib was combined with SABR, the composition of immune cells could be changed. More importantly, this two-pronged approach evoked tumor antigen–specific immune responses and the mice were resistant to another tumor rechallenge, finally, long-term survival was improved. Conclusion Our results suggested that the tumor microenvironment could be managed with apatinib, which was effective in eliciting an abscopal effect induced by SABR.
Percutaneous catheter drainage for abscess after surgery
Wen-Bo Zhu,Xiao-Hui Zhao,Hai-Liang Li,Chen-Yang Guo,Quan-Jun Yao,Xiang Geng,Ke Zhao,Hong-Tao Hu 소화기인터벤션의학회 2022 International journal of gastrointestinal interven Vol.11 No.4
Percutaneous abscess drainage (PAD) has been proven to be a safe, effective, and widely used technique for the treatment of patients with abscesses after gastrointestinal surgery. The indications for PAD are expanding and most postoperative abscesses of the gastrointestinal tract are susceptible to PAD. PAD uses various imaging methods, including ultrasound, computed tomography, and several safe and reliable catheter insertion methods.
Percutaneous catheter drainage for abscess after surgery
Wen-Bo Zhu,Xiao-Hui Zhao,Hai-Liang Li,Chen-Yang Guo,Quan-Jun Yao,Xiang Geng,Ke Zhao,Hong-Tao Hu 소화기인터벤션의학회 2022 Gastrointestinal Intervention Vol.11 No.4
Percutaneous abscess drainage (PAD) has been proven to be a safe, effective, and widely used technique for the treatment of patients with abscesses after gastrointestinal surgery. The indications for PAD are expanding and most postoperative abscesses of the gastrointestinal tract are susceptible to PAD. PAD uses various imaging methods, including ultrasound, computed tomography, and several safe and reliable catheter insertion methods.
Yi-Wen Geng,Xue Zhang,Xiaoqiang Li,Kai Wang,Xibo Yuan 전력전자학회 2017 JOURNAL OF POWER ELECTRONICS Vol.17 No.3
The output voltage of an off-grid inverter is influenced by load current, and the voltage harmonics especially the 5th and 7th are increased with nonlinear loads. In this paper, to attenuate the output voltage harmonics of off-grid inverters with nonlinear loads nearby, a load current feedforward is proposed. It is introduced to a voltage control loop based on the Positive and Negative Sequence Harmonic Regulator (PNSHR) compensation to modify the output impedance at selective frequencies. The parameters of the PNSHR are revised with the output impedance of the off-grid inverter, which minimizes the output impedance of the off-grid inverter. Experimental results verify the proposed method, showing that the output voltage harmonics caused by nonlinear loads can be effectively suppressed.