http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
NON CONVENTIONAL METHOD FOR SOFT STARTING OF THREE PHASE INDUCTION MOTORS
Nabil A. Ahmed,Sung-Jun Kim,Ki-Young Suh,Soon-Kurl Kown,Hyun-Woo Lee 전력전자학회 2004 전력전자학술대회 논문집 Vol.- No.-
This paper presents a nonconventional method for soft starting of three-phase induction motors, which achieved by flux weakening technique. Flux weakening is not done by reducing the applied voltage as in the conventional methods. Flux weakening is achieved by increasing the supply frequency over the rated value while the voltage amplitude is kept constant. This method has advantage of reducing the stress on the electrical and mechanical systems. The feasibility of this basic idea has been confirmed through investigating the starting transient corresponding to this mode of operation. For this purpose, a rigorous state space mathematical model has been developed and simulated. The validity of the proposed method through the results from the mathematical model have been confirmed experimentally.