http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Utility of skull X-rays in identifying recurrence of coiled cerebral aneurysms
Chen Peng Roc,Lopez-Rivera Victor,Conner Christopher R,Sanzgiri Aditya,Sheth Sunil A.,Erkmen Kadir,Kim Dong H,Day Arthur L. 대한뇌혈관외과학회 2021 Journal of Cerebrovascular and Endovascular Neuros Vol.23 No.2
Objective A high rate of cerebral aneurysm recurrence following endovascular coiling has prompted the use of digital subtraction angiography (DSA) for interval follow-up. However, the utility of skull x-rays as an alternative screening method for aneurysm recurrence is unproperly characterized. Methods Retrospective review of a prospective registry of ruptured and unruptured cerebral aneurysms. Anteroposterior and lateral skull x-rays were obtained immediately at the end of the procedure and at 6-month follow-up. Aneurysm recurrence was defined by comparing post-procedure and 6-month DSA imaging. A true positive was defined as a change in coil mass morphology on at least one projection with aneurysm recurrence on DSA, and a true negative defined as a stable coil mass on both projections and no recurrence on DSA. Receiver operating characteristic area under the curve (AUC) statistics was used to assess the performance of skull x-rays in identifying aneurysm recurrence. Results A total of 118 cerebral aneurysms were evaluated with DSA imaging and skull x-rays. A change in coil mass morphology on one projection of skull x-rays correctly detected all true recurrences with a sensitivity of 100% (95% confidence interval [CI], 91-100%). Skull x-rays failed to identify a stable aneurysm coil mass in 15 cases, with a specificity of 79% (68-88%). Skull x-rays performed with AUC 0.8958 (95% CI, 0.8490-0.9431) in identifying aneurysm recurrence. Conclusions The findings of our study suggest that skull x-rays may represent a low-cost, non-invasive screening tool to rule out aneurysm recurrence, which can potentially aid in decreasing the utilization of DSA in the follow-up of patients with coiled cerebral aneurysms. Objective A high rate of cerebral aneurysm recurrence following endovascular coiling has prompted the use of digital subtraction angiography (DSA) for interval follow-up. However, the utility of skull x-rays as an alternative screening method for aneurysm recurrence is unproperly characterized. Methods Retrospective review of a prospective registry of ruptured and unruptured cerebral aneurysms. Anteroposterior and lateral skull x-rays were obtained immediately at the end of the procedure and at 6-month follow-up. Aneurysm recurrence was defined by comparing post-procedure and 6-month DSA imaging. A true positive was defined as a change in coil mass morphology on at least one projection with aneurysm recurrence on DSA, and a true negative defined as a stable coil mass on both projections and no recurrence on DSA. Receiver operating characteristic area under the curve (AUC) statistics was used to assess the performance of skull x-rays in identifying aneurysm recurrence. Results A total of 118 cerebral aneurysms were evaluated with DSA imaging and skull x-rays. A change in coil mass morphology on one projection of skull x-rays correctly detected all true recurrences with a sensitivity of 100% (95% confidence interval [CI], 91-100%). Skull x-rays failed to identify a stable aneurysm coil mass in 15 cases, with a specificity of 79% (68-88%). Skull x-rays performed with AUC 0.8958 (95% CI, 0.8490-0.9431) in identifying aneurysm recurrence. Conclusions The findings of our study suggest that skull x-rays may represent a low-cost, non-invasive screening tool to rule out aneurysm recurrence, which can potentially aid in decreasing the utilization of DSA in the follow-up of patients with coiled cerebral aneurysms.