RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Prevalence and location of the posterior superior alveolar artery using cone-beam computed tomography

        Tehranchi, Maryam,Taleghani, Ferial,Shahab, Shahriar,Nouri, Arash Korean Academy of Oral and Maxillofacial Radiology 2017 Imaging Science in Dentistry Vol.47 No.1

        Purpose: Insufficient knowledge of the anatomy of the maxillary sinuses prior to sinus graft surgery may lead to perioperative or postoperative complications. This study sought to characterize the position of the posterior superior alveolar artery (PSAA) within the maxillary sinuses using cone-beam computed tomography (CBCT). Materials and Methods: A total of 300 patients with edentulous posterior maxillae, including 138 females and 162 males with an age range of 33-86 years, who presented to a radiology clinic between 2013 and 2015 were enrolled in this retrospective cross-sectional study. The distance from the inferior border of the PSAA to the alveolar crest according to the residual ridge classification by Lekholm and Zarb, the distance from the PSAA to the nasal septum and zygomatic arch, and the diameter and position of the PSAA were all assessed on patients' CBCT scans. The data were analyzed using the Mann-Whitney test and the t-test. Results: The PSAA was detected on the CBCT scans of 87% of the patients; it was located beneath the sinus membrane in 47% of cases and was intraosseous in 47% of cases. The diameter of the artery was between 1 and 2 mm in most patients (72%). The mean diameter of the artery was $1.29{\pm}0.39mm$, and the mean distances from the PSAA to the zygomatic arch, nasal septum, and alveolar crest were $22.59{\pm}4.89mm$, $26.51{\pm}3.52mm$, and $16.7{\pm}3.96mm$, respectively. Conclusion: The likelihood of detecting the PSAA on CBCT scans is high; its location is intraosseous or beneath the sinus membrane in most patients. Determining the exact location of the PSAA on CBCT scans preoperatively can help prevent it from being damaged during surgery.

      • SCOPUSKCI등재

        Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system

        Mohammadpour, Mahdis,Bakhshalian, Neema,Shahab, Shahriar,Sadeghi, Shaya,Ataee, Mona,Sarikhani, Soodeh Korean Academy of Oral and Maxillofacial Radiology 2014 Imaging Science in Dentistry Vol.44 No.2

        Purpose: Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This study evaluated and compared the effects of intracanal stainless steel or titanium posts on the sensitivity, specificity, and accuracy of VRF detection using a NewTom VG CBCT system. Materials and Methods: Eighty extracted single-rooted teeth were selected and sectioned at the cemento-enamel junction. The roots were divided into two groups of 40. Root fracture was induced in the test group by using an Instron machine, while the control group was kept intact. Roots were randomly embedded in acrylic blocks and radiographed with the NewTom VG, both with titanium and stainless steel posts and also without posts. Sensitivity, specificity, and accuracy values were calculated as compared to the gold standard. Results: The sensitivity, specificity, and accuracy of VRF diagnosis were significantly lower in teeth with stainless steel and titanium posts than in those without posts. Interobserver agreement was the highest in teeth without posts, followed by stainless steel posts, and then titanium posts. Conclusion: Intracanal posts significantly decreased the VRF diagnostic values of CBCT. The stainless steel posts decreased the diagnostic values more than the titanium posts.

      • KCI등재

        Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system

        Mahdis Mohammadpour,Neema Bakhshalian,Shahriar Shahab,Shaya Sadeghi,Soodeh Sarikhani 대한영상치의학회 2014 Imaging Science in Dentistry Vol.44 No.2

        Purpose: Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This study evaluated and compared the effects of intracanal stainless steel or titanium posts on the sensitivity, specificity, and accuracy of VRF detection using a NewTom VG CBCT system. Materials and Methods: Eighty extracted single-rooted teeth were selected and sectioned at the cemento-enamel junction. The roots were divided into two groups of 40. Root fracture was induced in the test group by using an Instron machine, while the control group was kept intact. Roots were randomly embedded in acrylic blocks and radiographed with the NewTom VG, both with titanium and stainless steel posts and also without posts. Sensitivity, specificity, and accuracy values were calculated as compared to the gold standard. Results: The sensitivity, specificity, and accuracy of VRF diagnosis were significantly lower in teeth with stainless steel and titanium posts than in those without posts. Interobserver agreement was the highest in teeth without posts, followed by stainless steel posts, and then titanium posts. Conclusion: Intracanal posts significantly decreased the VRF diagnostic values of CBCT. The stainless steel posts decreased the diagnostic values more than the titanium posts.

      • KCI등재

        Prevalence and location of the posterior superior alveolar artery using cone-beam computed tomography

        Maryam Tehranchi,Ferial Taleghani,Shahriar Shahab,Arash Nouri 대한영상치의학회 2017 Imaging Science in Dentistry Vol.47 No.1

        Purpose: Insufficient knowledge of the anatomy of the maxillary sinuses prior to sinus graft surgery may lead to perioperative or postoperative complications. This study sought to characterize the position of the posterior superior alveolar artery (PSAA) within the maxillary sinuses using cone-beam computed tomography (CBCT). Materials and Methods: A total of 300 patients with edentulous posterior maxillae, including 138 females and 162 males with an age range of 33-86 years, who presented to a radiology clinic between 2013 and 2015 were enrolled in this retrospective cross-sectional study. The distance from the inferior border of the PSAA to the alveolar crest according to the residual ridge classification by Lekholm and Zarb, the distance from the PSAA to the nasal septum and zygomatic arch, and the diameter and position of the PSAA were all assessed on patients’ CBCT scans. The data were analyzed using the Mann-Whitney test and the t-test. Results: The PSAA was detected on the CBCT scans of 87% of the patients; it was located beneath the sinus membrane in 47% of cases and was intraosseous in 47% of cases. The diameter of the artery was between 1 and 2 mm in most patients (72%). The mean diameter of the artery was 1.29±0.39 mm, and the mean distances from the PSAA to the zygomatic arch, nasal septum, and alveolar crest were 22.59±4.89 mm, 26.51±3.52 mm, and 16.7±3.96 mm, respectively. Conclusion: The likelihood of detecting the PSAA on CBCT scans is high; its location is intraosseous or beneath the sinus membrane in most patients. Determining the exact location of the PSAA on CBCT scans preoperatively can help prevent it from being damaged during surgery.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼