http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Colorectal Cancer Staging Using Three Clustering Methods Based on Preoperative Clinical Findings
Pourahmad, Saeedeh,Pourhashemi, Soudabeh,Mohammadianpanah, Mohammad Asian Pacific Journal of Cancer Prevention 2016 Asian Pacific journal of cancer prevention Vol.17 No.2
Determination of the colorectal cancer stage is possible only after surgery based on pathology results. However, sometimes this may prove impossible. The aim of the present study was to determine colorectal cancer stage using three clustering methods based on preoperative clinical findings. All patients referred to the Colorectal Research Center of Shiraz University of Medical Sciences for colorectal cancer surgery during 2006 to 2014 were enrolled in the study. Accordingly, 117 cases participated. Three clustering algorithms were utilized including k-means, hierarchical and fuzzy c-means clustering methods. External validity measures such as sensitivity, specificity and accuracy were used for evaluation of the methods. The results revealed maximum accuracy and sensitivity values for the hierarchical and a maximum specificity value for the fuzzy c-means clustering methods. Furthermore, according to the internal validity measures for the present data set, the optimal number of clusters was two (silhouette coefficient) and the fuzzy c-means algorithm was more appropriate than the k-means clustering approach by increasing the number of clusters.
Effect of organic acids in dental biofilm on microhardness of a silorane-based composite
Hashemikamangar, Sedighe Sadat,Pourhashemi, Seyed Jalal,Talebi, Mohammad,Kiomarsi, Nazanin,Kharazifard, Mohammad Javad The Korean Academy of Conservative Dentistry 2015 Restorative Dentistry & Endodontics Vol.40 No.3
Objectives: This study evaluated the effect of lactic acid and acetic acid on the microhardness of a silorane-based composite compared to two methacrylate-based composite resins. Materials and Methods: Thirty disc-shaped specimens each were fabricated of Filtek P90, Filtek Z250 and Filtek Z350XT. After measuring of Vickers microhardness, they were randomly divided into 3 subgroups (n = 10) and immersed in lactic acid, acetic acid or distilled water. Microhardness was measured after 48 hr and 7 day of immersion. Data were analyzed using repeated measures ANOVA (p < 0.05). The surfaces of two additional specimens were evaluated using a scanning electron microscope (SEM) before and after immersion. Results: All groups showed a reduction in microhardness after 7 day of immersion (p < 0.001). At baseline and 7 day, the microhardness of Z250 was the greatest, followed by Z350 and P90 (p < 0.001). At 48 hr, the microhardness values of Z250 and Z350 were greater than P90 (p < 0.001 for both), but those of Z250 and Z350 were not significantly different (p = 0.095). Also, the effect of storage media on microhardness was not significant at baseline, but significant at 48 hr and after 7 day (p = 0.001 and p < 0.001, respectively). Lactic acid had the greatest effect. Conclusions: The microhardness of composites decreased after 7 day of immersion. The microhardness of P90 was lower than that of other composites. Lactic acid caused a greater reduction in microhardness compared to other solutions.
Effect of organic acids in dental biofilm on microhardness of a silorane-based composite
Sedighe Sadat HashemiKamangar,Seyed Jalal Pourhashemi,Mohammad Talebi,Nazanin Kiomarsi,Mohammad Javad Kharazifard 대한치과보존학회 2015 Restorative Dentistry & Endodontics Vol.40 No.3
Objectives: This study evaluated the effect of lactic acid and acetic acid on the microhardness of a silorane-based composite compared to two methacrylate-based composite resins. Materials and Methods: Thirty disc-shaped specimens each were fabricated of Filtek P90, Filtek Z250 and Filtek Z350XT. After measuring of Vickers microhardness, they were randomly divided into 3 subgroups (n = 10) and immersed in lactic acid, acetic acid or distilled water. Microhardness was measured after 48 hr and 7 day of immersion. Data were analyzed using repeated measures ANOVA (p < 0.05). The surfaces of two additional specimens were evaluated using a scanning electron microscope (SEM) before and after immersion. Results: All groups showed a reduction in microhardness after 7 day of immersion (p < 0.001). At baseline and 7 day, the microhardness of Z250 was the greatest, followed by Z350 and P90 (p < 0.001). At 48 hr, the microhardness values of Z250 and Z350 were greater than P90 (p < 0.001 for both), but those of Z250 and Z350 were not significantly different (p = 0.095). Also, the effect of storage media on microhardness was not significant at baseline, but significant at 48 hr and after 7 day (p = 0.001 and p < 0.001, respectively). Lactic acid had the greatest effect. Conclusions: The microhardness of composites decreased after 7 day of immersion. The microhardness of P90 was lower than that of other composites. Lactic acid caused a greater reduction in microhardness compared to other solutions.
Hashemi Kamangar, Sedighe Sadat,Ghavam, Maryam,Mahinfar, Nazanin,Pourhashemi, Seyed Jalal The Korean Academy of Conservative Dentistry 2014 Restorative Dentistry & Endodontics Vol.39 No.3
Objectives: This study aimed to assess the effect of 38% carbamide peroxide on the microleakage of class V cavities restored with either a silorane-based composite or two methacrylate-based composites. Materials and Methods: A total of 96 class V cavities were prepared on the buccal surface of extracted human teeth with both enamel and dentin margins and were randomly assigned into three groups of Filtek P90 (3M-ESPE) + P90 system adhesive (3M-ESPE)(group A), Filtek Z250 (3M-ESPE) + Adper Prompt L-Pop (3M-ESPE)(group B) and Filtek Z350XT (3M-ESPE) + Adper Prompt L-Pop (group C). Half of the teeth were randomly underwent bleaching (38% carbamide peroxide, Day White, Discus Dental, applying for 15 min, twice a day for 14 day) while the remaining half (control) were not bleached. Dye penetration was measured following immersion in basic fuchsine. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests at a level of 0.05. Results: No significant differences were found between composites in the control groups in enamel (p = 0.171) or dentin (p = 0.094) margins. After bleaching, microleakage of Z250 (in enamel [p = 0.867] or dentin [p = 0.590] margins) and Z350 (in enamel [p = 0.445] or dentin [p = 0.591]margins) did not change significantly, but the microleakage of P90 significantly increased in both enamel (p = 0.042) and dentin (p = 0.002) margins. Conclusions: No significant differences were noted between the bleached and control subgroups of two methacrylate-based composites in enamel or dentin margins. Microleakage of silorane-based composite significantly increased after bleaching.
Sedighe Sadat Hashemi Kamangar,Maryam Ghavam,Nazanin Mahinfar,Seyed Jalal Pourhashemi 대한치과보존학회 2014 Restorative Dentistry & Endodontics Vol.39 No.3
Objectives: This study aimed to assess the effect of 38% carbamide peroxide on the microleakage of class V cavities restored with either a silorane-based composite or two methacrylate-based composites. Materials and Methods: A total of 96 class V cavities were prepared on the buccal surface of extracted human teeth with both enamel and dentin margins and were randomly assigned into three groups of Filtek P90 (3M-ESPE) + P90 system adhesive (3M-ESPE)(group A), Filtek Z250 (3M-ESPE) + Adper Prompt L-Pop (3M-ESPE)(group B) and Filtek Z350XT (3M-ESPE) + Adper Prompt L-Pop (group C). Half of the teeth were randomly underwent bleaching (38% carbamide peroxide, Day White, Discus Dental, applying for 15 min, twice a day for 14 day) while the remaining half (control) were not bleached. Dye penetration was measured following immersion in basic fuchsine. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests at a level of 0.05. Results: No significant differences were found between composites in the control groups in enamel (p = 0.171) or dentin (p = 0.094) margins. After bleaching, microleakage of Z250 (in enamel [p = 0.867] or dentin [p = 0.590] margins) and Z350 (in enamel [p = 0.445] or dentin [p = 0.591]margins) did not change significantly, but the microleakage of P90 significantly increased in both enamel (p = 0.042) and dentin (p = 0.002) margins. Conclusions: No significant differences were noted between the bleached and control subgroups of two methacrylate-based composites in enamel or dentin margins. Microleakage of silorane-based composite significantly increased after bleaching.